Description

Schneider A9D11840 |Acti9 iC60 current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 pole, 40A

Product Overview: Schneider A9D11840 | iC60H RCBO – 1P+N – 40A – C Curve – 30mA – 240V

The Schneider Electric A9D11840 is a premium-quality earth leakage circuit breaker from the Acti9 iC60H series. This model features a 1P+N configuration, a C curve tripping characteristic, a rated current of 40A, and a residual current sensitivity of 30 mA, making it ideal for protection against both overcurrents and earth leakage in low-voltage circuits operating at 240V AC.

Key Features:

  • Brand: Schneider Electric

  • Series: Acti9 iC60H

  • Model Number: A9D11840

  • Product Type: RCBO (Residual Current Breaker with Overcurrent)

  • Poles: 1P + N (Single Pole + Neutral)

  • Tripping Curve: C Curve

  • Rated Current: 40A

  • Residual Current Sensitivity: 30 mA

  • Rated Voltage: 240V AC

Technical Specifications:

  • Breaking Capacity: High fault current interruption capacity

  • Sensitivity: 30 mA – ensures personal protection against electric shocks

  • Tripping Characteristic: Type C – suitable for standard load protection with moderate inrush

  • Frequency: 50/60 Hz

  • Mounting: DIN rail compatible

  • Standards Compliance: IEC 61009-1

Functional Features:

  • Dual Protection:
    – Protects from both earth leakage faults and overcurrent events (overload, short circuit)

  • Compact Housing:
    – Space-saving design ideal for panel boards

  • Status Indicators:
    – Clearly marked ON/OFF and fault positions

  • Durability:
    – High mechanical and electrical endurance

  • Manual Reset:
    – Allows for easy restart after fault resolution

Applications:

  • Residential installations

  • Commercial building circuits

  • Socket outlets and HVAC systems

  • Lighting and general-purpose protection

  • Moist or sensitive areas requiring RCD protection

Benefits:

  • Maximum Safety:
    – 30 mA sensitivity detects life-threatening leakage currents

  • Quick Tripping:
    – Fast response time for fault isolation

  • Reliable Operation:
    – Trusted Schneider quality and technology

  • Time Saving:
    – Easy to install and reset

  • Space Optimized:
    – Single module width for 1P+N design

Typical Users:

  • Electricians and system installers

  • Residential and commercial property developers

  • Maintenance technicians

  • Electrical consultants

  • Panel builders and OEMs

Additional information

brands

Schneider Electric

Specifications

Main
circuit breaker application Distribution
Range Acti9
Product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60H RCBO
Poles description 1P + Ns
[In] rated current 40 A at 50 °C
Earthing system TN
Curve code C
Earth-leakage sensitivity 30 mA
Breaking capacity 10000 A Icn at 230/240 V AC 50/60 Hz
Complementary
Neutral position Left
Number of protected poles 1
device location in system Outgoer
Network frequency 50 Hz
Network type AC
Trip unit technology Thermal-magnetic
[Ue] rated operational voltage 230/240 V AC 50/60 Hz
Residual current tripping technology Voltage dependent
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
[Icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity 7500 A at 230/240 V AC 50/60 Hz
Limitation class 3
[Ui] rated insulation voltage 400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Suitability for isolation Yes
Contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
Mounting mode Clip-on
mounting support DIN rail
Comb busbar and distribution block compatibility NO
9 mm pitches 2
height 110 mm
Width 18 mm
Depth 77.5 mm
Net weight 205 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 5000 cycles
Provision for padlocking Padlockable with padlock Ø 4 mm
Locking options description ON/OFF locking facilities
Connections - terminals Screw clamp terminal (top) 1…25 mm² rigid without cable end Screw clamp terminal (top) 1…16 mm² flexible Screw clamp terminal (bottom) 1…16 mm² rigid without cable end Screw clamp terminal (bottom) 1…10 mm² flexible
Wire stripping length Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Tightening torque Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom
earth-leakage protection Integrated
Environment
Standards BS EN 61009-1 IEC 61009-2-2 AS/NZS 61009.1 IEC 61009-1
IP degree of protection IP20
Tropicalisation 2
Relative humidity 95 % at 55 °C
ambient air temperature for operation -15…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.7 cm
Package 1 Width 11.2 cm
Package 1 Length 13.8 cm
Package 1 Weight 246.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 34
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 8.74 kg
Unit Type of Package 3 P06
Number of Units in Package 3 544
Package 3 Height 75.0 cm
Package 3 Width 80.0 cm
Package 3 Length 60.0 cm
Package 3 Weight 137.0 kg

Main Document

Main Document

Data Sheet : A9D11840

Main Document

Data Sheet : A9D11840

Reviews (0)

Be the first to review “Schneider A9D11840 | iC60H – earth leakage circuit breaker – 1P + N – C curve – 40 A – 30 mA – 240 V”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products