Description

Schneider A9D11816 | Acti9 iC60 current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 16A

Schneider A9D11816: A Comprehensive Overview

In today’s rapidly evolving world, where safety and efficiency are paramount, investing in high-quality electrical components is non-negotiable. One such component gaining traction in the market is the Schneider A9D11816 miniature circuit breaker (MCB). In this article, we’ll delve into the intricacies of the Schneider A9D11816, exploring its features, applications, installation process, maintenance requirements, and much more.

1. Introduction to Schneider A9D11816

Schneider A9D11816 is a miniature circuit breaker designed to provide reliable overcurrent protection for residential, commercial, and industrial applications. Renowned for its compact design and superior performance, the A9D11816 model has become a preferred choice among professionals and homeowners alike.

2. Understanding the A9D11816 model

Key features

The A9D11816 boasts several notable features that set it apart from conventional circuit breakers. With its compact size and DIN rail mounting capability, it offers seamless integration into existing electrical panels. Moreover, its high breaking capacity ensures efficient protection against short circuits and overloads.

Specifications

  • Rated current: 16A
  • Rated voltage: 230/400V AC
  • Breaking capacity: 10 kA
  • Number of poles: 1P
  • Trip curve: C

3. Applications of Schneider A9D11816

Residential use

In residential settings, the A9D11816 serves as a safeguard against electrical hazards, protecting appliances, wiring, and inhabitants from potential damage or injury. Whether it’s in kitchens, bedrooms, or utility rooms, this MCB provides reliable overcurrent protection, giving homeowners peace of mind.

Commercial use

In commercial environments such as offices, retail stores, and educational institutions, the A9D11816 plays a crucial role in ensuring uninterrupted power supply and preventing downtime due to electrical faults. Its robust construction and dependable performance make it an ideal choice for various commercial applications.

4. Installation process

Safety precautions

Before installing the Schneider A9D11816, it’s essential to prioritize safety. Ensure that the power supply is switched off and take necessary precautions to avoid electrical shocks. Additionally, wear appropriate personal protective equipment (PPE) during installation.

Step-by-step guide

  1. Identify the location for installation within the electrical panel.
  2. Remove the cover from the panel to access the mounting area.
  3. Securely mount the A9D11816 on the DIN rail, ensuring proper alignment.
  4. Connect the incoming and outgoing electrical wires to the MCB terminals, following the manufacturer’s guidelines.
  5. Double-check all connections for accuracy and tightness.
  6. Reattach the panel cover and restore power to the circuit.

5. Maintenance and troubleshooting

Tips for maintenance

Regular maintenance is essential to ensure the optimal performance of the Schneider A9D11816. Periodically inspect the MCB for signs of wear or damage, such as overheating or corrosion. Clean the contacts and terminals as needed to maintain proper conductivity.

Common issues and solutions

  • Tripping: If the MCB frequently trips without apparent cause, check for overloaded circuits or faulty appliances. Distribute the load evenly across circuits and replace malfunctioning devices if necessary.
  • Contact resistance: Over time, the contacts inside the MCB may develop resistance, leading to poor connectivity. Clean the contacts or replace the MCB if resistance is excessive.

6. Comparing A9D11816 with other models

Advantages over competitors

  • Compact design: The A9D11816’s compact size allows for more efficient use of space within electrical panels compared to bulkier alternatives.
  • High breaking capacity: With a breaking capacity of 10 kA, the A9D11816 offers superior protection against short circuits and overloads.
  • Reliable performance: Schneider Electric’s reputation for quality and reliability ensures that the A9D11816 delivers consistent performance in diverse applications.

Limitations

  • Single-pole configuration: While suitable for many applications, the A9D11816’s single-pole design may limit its compatibility with certain systems requiring multipole protection.

7. Customer reviews and testimonials

Feedback from customers who have used the Schneider A9D11816 can provide valuable insights into its performance and reliability. Positive reviews often highlight its durability, ease of installation, and effective protection against electrical faults.

8. Future prospects and advancements

As technology continues to evolve, Schneider Electric remains committed to enhancing the functionality and efficiency of its products, including the A9D11816. Future advancements may include smart features such as remote monitoring and diagnostics, further enhancing its value proposition for users.

9. Conclusion

In conclusion, the Schneider A9D11816 miniature circuit breaker stands as a testament to innovation and reliability in electrical protection systems. Its compact design, robust construction, and advanced features make it an indispensable asset for residential, commercial, and industrial applications alike. By prioritizing safety, investing in quality components, and staying informed about maintenance best practices, users can maximize the lifespan and performance of the A9D11816, ensuring uninterrupted power supply and peace of mind.

Additional information

brands

Schneider Electric

Specifications

Main
circuit breaker application Distribution
Range Acti9
Product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60H RCBO
Poles description 1P + Ns
[In] rated current 16 A at 50 °C
Earthing system TN
Curve code C
Earth-leakage sensitivity 30 mA
Breaking capacity 10000 A Icn at 230/240 V AC 50/60 Hz
Complementary
Neutral position Left
Number of protected poles 1
device location in system Outgoer
Network frequency 50 Hz
Network type AC
Trip unit technology Thermal-magnetic
[Ue] rated operational voltage 230/240 V AC 50/60 Hz
Residual current tripping technology Voltage dependent
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
[Icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity 7500 A at 230/240 V AC 50/60 Hz
Limitation class 3
[Ui] rated insulation voltage 400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Suitability for isolation Yes
Contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
Mounting mode Clip-on
mounting support DIN rail
Comb busbar and distribution block compatibility NO
9 mm pitches 2
height 110 mm
Width 18 mm
Depth 77.5 mm
Net weight 205 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 5000 cycles
Provision for padlocking Padlockable with padlock Ø 4 mm
Locking options description ON/OFF locking facilities
Connections - terminals Screw clamp terminal (top) 1…25 mm² rigid without cable end Screw clamp terminal (top) 1…16 mm² flexible Screw clamp terminal (bottom) 1…16 mm² rigid without cable end Screw clamp terminal (bottom) 1…10 mm² flexible
Wire stripping length Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection
Tightening torque Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom
earth-leakage protection Integrated
Environment
Standards BS EN 61009-1 IEC 61009-1 IEC 61009-2-2 AS/NZS 61009.1
IP degree of protection IP20
Tropicalisation 2
Relative humidity 95 % at 55 °C
ambient air temperature for operation -15…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.5 cm
Package 1 Width 11.2 cm
Package 1 Length 13.8 cm
Package 1 Weight 218 g
Unit Type of Package 2 S02
Number of Units in Package 2 34
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.73 kg
Unit Type of Package 3 P12
Number of Units in Package 3 1088
Package 3 Height 75 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 262.88 kg

Main Document

Main Document

Data Sheet : A9D11816 

Main Document

Data Sheet : A9D11816 

Reviews (0)

Be the first to review “Schneider A9D11816 | iC60H – earth leakage circuit breaker – 1P + N – C curve – 16 A – 30 mA – 240 V”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare