Description

Schneider A9F74302 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 2A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)

Product Overview: Schneider A9F74302 | Miniature Circuit Breaker (MCB) – Acti9 iC60N – 3P – 2A – C Curve – 6000A

The Schneider Electric A9F74302 is a 3-pole Miniature Circuit Breaker (MCB) from the trusted Acti9 iC60N range, designed to offer precise protection for circuits requiring low current rating and high safety standards. With a rated current of 2A, C curve tripping, and breaking capacity of 6000 A (IEC/EN 60898-1) and up to 50 kA (IEC/EN 60947-2), it ensures excellent performance in various electrical environments.

Key Features:

  • Brand: Schneider Electric

  • Range: Acti9 iC60N

  • Model Number: A9F74302

  • Type: Miniature Circuit Breaker (MCB)

  • Number of Poles: 3P (Triple Pole)

  • Rated Current: 2 Amperes

  • Tripping Curve: C Curve

  • Breaking Capacity:
    – 6 kA (IEC/EN 60898-1)
    – Up to 50 kA (IEC/EN 60947-2)

  • Rated Operational Voltage: 400 V AC

  • Frequency: 50/60 Hz

Technical Specifications:

  • Mounting: DIN rail (35 mm)

  • Terminal Capacity: 1.5–25 mm² (flexible/rigid cables)

  • Operating Temperature: −25°C to +70°C

  • IP Rating: IP20 (with terminal covers)

  • Endurance:
    – Electrical: up to 10,000 cycles
    – Mechanical: up to 20,000 cycles

  • Conformity Standards:
    – IEC/EN 60898-1
    – IEC/EN 60947-2

Functional Characteristics:

  • C Curve Tripping:
    – Trips between 5 to 10 times the rated current
    – Ideal for protecting general-purpose loads such as lighting, receptacles, and small motors

  • Fault Protection:
    – Overload protection
    – Short-circuit protection

  • Indicators:
    – ON/OFF/Tripped position status

  • Accessory Compatibility:
    – Fully compatible with Acti9 iOF auxiliary contacts, alarms, and remote-control accessories

Applications:

  • Industrial control panels

  • Distribution boards in commercial buildings

  • Sub-circuits in manufacturing plants

  • Lighting and power circuits requiring low amperage

  • Equipment and process protection in sensitive installations

Why Choose A9F74302?

  •  Trusted Schneider Electric quality

  •  Enhanced safety with high breaking capacity

  •  Easy installation and modular expandability

  •  Durable for both electrical and mechanical longevity

  •  Ideal for low-current, three-phase circuits

Recommended For:

  • Electrical consultants and engineers

  • Industrial electricians

  • Panel manufacturers

  • Maintenance teams

  • Facilities management

Additional information

brands

Schneider Electric

Specifications

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name IC60N
Poles description 3P
Number of protected poles 3
[In] rated current 2 A
Network type AC DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2
Standards EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1
Quality labels NF
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 125...180 V DC 10 kA 100 % conforming to EN 60947-2 - 125...180 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 6
height 85 mm
Width 54 mm
Depth 78.5 mm
Net weight 0.375 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.5 cm
Package 1 Width 7.3 cm
Package 1 Length 9.3 cm
Package 1 Weight 334.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 4
Package 2 Height 8.0 cm
Package 2 Width 10.0 cm
Package 2 Length 22.5 cm
Package 2 Weight 1.384 kg
Unit Type of Package 3 S03
Number of Units in Package 3 44
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 15.717 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : A9F74302

Main Document

Data Sheet : A9F74302

Reviews (0)

Be the first to review “Schneider A9F74302 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 2A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare