1. Technical Specifications
-
Operational Voltage (Ue): Up to 240/415 V AC
-
Number of Poles: 1 (single-phase protection)
-
Rated Current (In): 6 Amperes
-
Tripping Curve: Type C — suitable for protection of circuits with moderate inrush currents, such as fluorescent lighting or small motors
-
Breaking Capacity:
-
6000 A (typically under IEC 60898-1, depending on regional variant)
-
-
Mounting: Standard 35 mm DIN rail
-
Frequency: 50/60 Hz
-
Degree of Protection: IP20 (IP40 with enclosure)
-
Insulation Class: Class II (double/reinforced insulation)
-
Electrical Endurance: Up to 20,000 load operations
-
Mechanical Endurance: Up to 20,000 manual operations
-
Operating Temperature Range: -25°C to +70°C
-
Compliance Standards: IEC 60898-1
2. Key Features
-
Reliable Overload and Short-Circuit Protection: Designed to protect low-current single-phase circuits from faults and overcurrents
-
C Curve Tripping: Suitable for circuits with standard inductive loads with moderate starting current
-
Compact Form Factor: Fits easily into residential or small commercial distribution boards
-
Clear Status Indication: Shows ON/OFF state for quick operational checks
-
Safe and Easy Installation: Finger-safe terminals, snap-on DIN rail mounting
-
Durability: High electrical and mechanical endurance for long-term use
-
Accessory Support: Compatible with selected iK60N accessories for additional control or indication features
-
Eco-Friendly Design: Made with recyclable materials and in line with RoHS environmental standards
3. Typical Applications
The A9K24106 MCB is primarily used for single-phase, low-load protection in residential, commercial, and light industrial systems:
-
Residential Electrical Panels: For protecting lighting circuits, wall sockets, or dedicated appliance circuits
-
Small Commercial Installations: In offices, retail stores, or service rooms
-
Control Panels: For protecting auxiliary control wiring or sensitive equipment
-
Lighting Circuits: Especially with LED or fluorescent fittings
-
Data and Communication Cabinets: To protect sensitive low-current devices
-
Educational and Institutional Buildings: In classrooms, labs, and administrative areas
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iK60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iK60N |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 6 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1 |
| Standards | EN/IEC 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 5...10 x In |
| [Ics] rated service breaking capacity | 6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 440 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60898-1 |
| Contact position indicator | No |
| control type | Toggle |
| local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 2 |
| height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Net weight | 100 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Tunnel type terminal (top or bottom) 1…25 mm² rigid Tunnel type terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 |
|---|---|
| Pollution degree | 2 conforming to EN/IEC 60898-1 |
| Overvoltage category | III |
| ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.000 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 99.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.500 cm |
| Package 2 Width | 9.500 cm |
| Package 2 Length | 22.000 cm |
| Package 2 Weight | 1.239 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 14.036 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9K24106
Main Document
Data Sheet : A9K24106
Reviews (0)
Recommended for you
Schneider A9K24325 | Miniature circuit-breaker, Acti9 iK60N, 3P, 25 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24363 | Miniature circuit-breaker, Acti9 iK60N, 3P, 63 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9K24316 | Miniature circuit-breaker, Acti9 iK60N, 3P, 16 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24240 | Miniature circuit-breaker, Acti9 iK60N, 2P, 40 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.