Schneider A9R44425 | Acti 9 iID – RCCB – 4P – 25A – 300mA – type AC
Schneider A9R44425 | Acti 9 iID – RCCB – 4P – 25A – 300mA – type AC
Description
Schneider A9R44425 | Acti 9 iID – RCCB – 4P – 25A – 300mA – type AC
Technical Specifications A9R44425
-
Product Code: A9R44425
-
Product Range: Acti 9 iID
-
Device Type: Residual Current Circuit Breaker (RCCB)
-
Number of Poles: 4 (Three-phase + Neutral)
-
Rated Current (In): 25 A
-
Rated Residual Operating Current (IΔn): 300 mA
-
Type: Type AC (detects sinusoidal alternating residual currents)
-
Rated Voltage: 400V AC (for three-phase systems)
-
Rated Frequency: 50/60 Hz
-
Tripping Characteristic: Instantaneous
-
Mounting Type: DIN rail
-
Degree of Protection: IP20 (protection against accidental contact)
-
Standards Compliance: IEC 61008-1
-
Test Button: Yes (for manual testing)
-
Mechanical Durability: > 5000 operations
-
Electrical Durability: > 2000 operations at rated load
Key Features
-
25A Rated Current: Suitable for low-power circuits that require protection against earth leakage currents.
-
300mA Sensitivity: Designed for fire protection, it detects larger residual currents that may not present an immediate shock risk but could lead to overheating or fire in electrical systems.
-
Type AC Detection: Capable of detecting sinusoidal AC leakage currents, making it suitable for typical residential and commercial installations.
-
4-Pole Protection: Provides complete protection for all conductors in three-phase systems, ensuring that all phases and neutral are disconnected in the event of a fault.
-
Instantaneous Tripping: The RCCB reacts immediately when the leakage current exceeds the rated threshold, minimizing the risk of damage or fire.
-
Test Button: Allows easy testing of the RCCB to verify its operation, ensuring the system remains safe and functional.
-
DIN Rail Mounting: Designed for easy integration into electrical distribution panels, saving space and simplifying installation.
-
Compliance with IEC Standards: Conforms to IEC 61008-1, ensuring global safety and performance standards.
Applications
The A9R44425 RCCB is intended for use in applications where fire protection is a primary concern due to earth leakage currents, especially in three-phase systems. It is suitable for:
Industrial Installations
-
Protects circuits in factories, manufacturing plants, and other industrial facilities that use three-phase electrical systems.
Commercial Buildings
-
Provides protection for electrical circuits in offices, shops, and warehouses, where extended leakage currents could present fire risks, especially in older or poorly maintained systems.
Residential Applications (Three-Phase Systems)
-
Suitable for large residential complexes or buildings with three-phase power systems, offering protection against potential fire risks due to earth leakage currents.
Electrical Distribution Panels
-
Ideal for installation in distribution boards or control panels, offering protection to circuits in larger or more complex electrical installations.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Acti9 |
|---|---|
| Product name | Acti9 iID |
| Product or component type | Residual current circuit breaker (RCCB) |
| Device short name | iID |
| Poles description | 4P |
| Neutral position | Left |
| [In] rated current | 25 A |
| Network type | AC |
| Earth-leakage sensitivity | 300 mA |
| earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type AC |
| device location in system | Outgoer |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 380...415 V AC 50/60 Hz |
| Residual current tripping technology | Voltage independent |
| Rated breaking and making capacity | Idm 1500 A Im 1500 A |
| Rated conditional short-circuit current | 10 kA |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Surge current | 250 A |
| Contact position indicator | Yes |
| control type | Toggle |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 8 |
| height | 91 mm |
| Width | 72 mm |
| Depth | 73.5 mm |
| Net weight | 0.37 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | AC-1: 15000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Standards | EN/IEC 61008-1 EN/IEC 61008-2-1 |
|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution degree | 3 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.6 cm |
| Package 1 Width | 8.5 cm |
| Package 1 Length | 10.0 cm |
| Package 1 Weight | 355.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 27 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 10.391 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9R41225 | Acti 9 iID – RCCB – 2P – 25A – 30mA – type AC
-
0
Schneider A9R41240 | Acti 9 iID – RCCB – 2P – 40A – 30mA – type AC
-
0
Schneider A9R14491 | Acti 9 iID – RCCB – 4P – 100A – 300mA – type AC
-
0
Schneider A9R14291 | Acti 9 iID – RCCB – 2P – 100A – 300mA – type AC
-
0
Schneider A9R14280 | Acti 9 iID – RCCB – 2P – 80A – 300mA – type AC
-
0
Reviews