Schneider G12T3A100 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection
Schneider G12T3A100 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection
Description
Schneider G12T3A100 | Circuit breaker, GoPact MCCB 125, 3 poles, 10kA at 415VAC, 100A rating, TMD trip unit, adjustable thermal protection
1. Technical Specifications G12T3A100
-
Product Name:
Molded Case Circuit Breaker (MCCB) -
Model Number:
G12T3A100 -
Product Family:
GoPact MCCB 125 Series by Schneider Electric -
Rated Current (In):
100 Amperes -
Number of Poles:
3 poles (suitable for three-phase applications) -
Breaking Capacity:
10 kA at 415 VAC (IEC 60947-2 rated) -
Rated Operational Voltage (Ue):
Up to 415 VAC -
Trip Unit Type:
TMD (Thermal Magnetic Trip Unit) -
Thermal Protection:
Adjustable thermal setting – allows customization of overload protection based on application requirements. -
Magnetic Protection:
Fixed magnetic trip setting – designed to respond quickly to short circuits. -
Mounting Type:
Fixed (non-withdrawable) -
Connection Type:
Suitable for cable or busbar connections -
Standards and Compliance:
-
IEC 60947-2
-
CE Marking
-
RoHS Compliant
-
Operating Temperature:
Typically -25°C to +70°C (refer to datasheet for specific derating) -
Insulation Voltage (Ui):
690 V -
Pollution Degree:
3 (suitable for industrial use)
2. Key Features G12T3A100
-
Adjustable Overload Protection:
The thermal protection is user-adjustable, providing flexibility in protecting different cable sizes and loads. -
Fixed Short-Circuit Protection:
Magnetic trip is pre-calibrated for quick fault interruption during short circuits, enhancing equipment and personnel safety. -
Compact Design:
Space-efficient dimensions make it ideal for installation in distribution panels with limited space. -
Reliable Performance:
Designed for consistent operation in industrial and commercial environments. -
High Dielectric Strength:
Rated for insulation up to 690 V, supporting safe operation in higher voltage installations. -
Simple Installation and Maintenance:
Front-access terminals and fixed mounting reduce installation time and make maintenance straightforward. -
Wide Application Range:
Suitable for both power distribution and motor protection scenarios. -
Environmentally Compliant:
RoHS-compliant construction, using materials safe for the environment and human health. -
Fully Compatible Accessories:
Can be used with GoPact accessories such as rotary handles, terminal covers, and auxiliary contacts. -
Mechanical Durability:
Designed for thousands of mechanical and electrical operations, ensuring long service life.
3. Common Applications
-
Industrial Electrical Panels:
Protects and controls three-phase power circuits in factories and processing plants. -
Power Distribution Boards:
Installed in low-voltage distribution panels to safeguard feeders and sub-circuits. -
Motor Control Applications:
Protects motors from overloads and short circuits when used in combination with contactors and starters. -
Building Electrical Systems:
Used in commercial and residential buildings to control and protect main or sub-main lines. -
Renewable Energy Systems:
Applied in solar and wind systems for power isolation and protection of inverter outputs. -
OEM and Machinery Panels:
Suitable for original equipment manufacturers building custom control panels for various machinery. -
Backup Generator Connections:
Used to safely isolate generator outputs or connect load banks for testing. -
Infrastructure Projects:
Ideal for water treatment plants, public lighting systems, and utility substations.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | GoPact MCCB |
|---|---|
| product or component type | Circuit breaker |
| Product name | GoPact MCCB 125 |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 10 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Performance level | T 10 kA 380/415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 440 V AC conforming to EN/IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 10 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 8000 cycles at 415 V In |
| Power dissipation per pole | 18.7 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Screw terminals |
| Connection pitch | 25 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.8...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 10 x In |
| Width (W) | 75 mm |
| Height (H) | 130 mm |
| Depth (D) | 60 mm |
| net weight | 0.7 kg |
| Colour | Grey (RAL 7035) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H |
|---|---|
| Overvoltage category | III |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C |
| ambient air temperature for storage | -35…85 °C |
| Operating altitude | 0...2000 m without derating 2000...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.4 cm |
| Package 1 Width | 8.5 cm |
| Package 1 Length | 13.9 cm |
| Package 1 Weight | 908 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7.579 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 128 |
| Package 3 Height | 75 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
Reviews