Schneider G80H3TM630 | Circuit breaker, GoPact MCCB 800, 3 poles, 70kA at 415VAC, 630A rating, TMD trip unit, adjustable thermal protection
Schneider G80H3TM630 | Circuit breaker, GoPact MCCB 800, 3 poles, 70kA at 415VAC, 630A rating, TMD trip unit, adjustable thermal protection
Description
Schneider G80H3TM630 | Circuit breaker, GoPact MCCB 800, 3 poles, 70kA at 415VAC, 630A rating, TMD trip unit, adjustable thermal protection
Technical Specifications
-
Full Model Name: Schneider G80H3TM630
-
Breaker Type: MCCB – Molded Case Circuit Breaker
-
Number of Poles: 3 poles
-
Breaking Capacity: 70 kA at 415V AC
-
Rated Current: 630 Amps
-
Trip Unit Type: TMD (Thermal Magnetic)
-
Thermal Protection: Adjustable
-
Operating Voltage: Up to 690V AC
-
Frequency: 50/60 Hz
-
Insulation Voltage: 800V
-
Degree of Protection: IP40 (when installed in a proper panel)
-
Standards Compliance: IEC 60947-2
Key Features and Benefits
-
High Protection Efficiency:
Equipped with a TMD trip unit, this breaker provides combined thermal and magnetic protection against overloads and short circuits. -
Adjustable Thermal Setting:
The thermal protection can be adjusted, allowing the breaker to be tailored to specific load characteristics and operating conditions. -
High Breaking Capacity:
With a breaking capacity of 70 kA, the G80H3TM630 is suitable for high-risk environments where strong and fast protection is essential. -
Compact Design:
Its space-saving design allows for easier installation in distribution panels, even where space is limited. -
Durability and Reliability:
Built with high-quality materials, it ensures long operational life and consistent performance in harsh environments. -
Ease of Installation and Maintenance:
The breaker is designed for quick mounting and safe wiring, with features that facilitate straightforward maintenance.
Typical Applications
-
Main and sub distribution boards in large industrial facilities
-
Commercial electrical systems, such as those in high-rise buildings, shopping malls, and hotels
-
Power generation and control panels in factories
-
Renewable energy systems, such as solar or wind farms
-
Data centers and mission-critical infrastructures where electrical safety is a top priority
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | GoPact MCCB |
|---|---|
| product or component type | Circuit breaker |
| Product name | GoPact MCCB 800 |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 630 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 70 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 80 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Performance level | H 70 kA 380/415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 440 V AC conforming to EN/IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 70 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 80 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Mechanical durability | 15000 cycles |
| Electrical durability | 3000 cycles at 415 V In |
| Power dissipation per pole | 60 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Screw terminals |
| Connection pitch | 60 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 630 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 10 x In |
| Width (W) | 180 mm |
| Height (H) | 250 mm |
| Depth (D) | 105 mm |
| net weight | 6.9 kg |
| Colour | Grey (RAL 7035) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H |
|---|---|
| Overvoltage category | III |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C |
| ambient air temperature for storage | -35…85 °C |
| Operating altitude | 0...2000 m without derating 2000...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 18 cm |
| Package 1 Width | 27 cm |
| Package 1 Length | 29 cm |
| Package 1 Weight | 11050 g |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 105 cm |
| Package 2 Width | 60 cm |
| Package 2 Length | 80 cm |
| Package 2 Weight | 146.392 kg |
Reviews