Schneider A9F77106 | Miniature circuit-breaker, Acti9 iC60N, 1P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Schneider A9F77106 | Miniature circuit-breaker, Acti9 iC60N, 1P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Description
Schneider A9F77106 | Miniature circuit-breaker, Acti9 iC60N, 1P, 6 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
1. Technical Specifications A9F77106
-
Product Reference: A9F77106
-
Product Series: Acti9 iC60N
-
Device Type: Miniature Circuit Breaker (MCB)
-
Number of Poles: 1P (single pole)
-
Rated Current (In): 6 A
-
Tripping Curve: C curve (trip between 5 to 10 times the rated current)
-
Rated Voltage:
-
230/400 V AC (IEC 60898-1)
-
440 V AC max (IEC 60947-2)
-
-
Breaking Capacity:
-
6 kA according to IEC 60898-1
-
10 kA according to IEC 60947-2
-
-
Frequency: 50/60 Hz
-
Insulation Voltage (Ui): 500 V
-
Pollution Degree: 3
-
Electrical Endurance: 20,000 operations
-
Mechanical Endurance: 20,000 operations
-
Mounting: DIN rail (clip-on)
-
Connection Terminals:
-
Top and bottom terminals with tunnel type screw clamps
-
Wire capacity: 1 to 25 mm²
-
-
Degree of Protection: IP20 (front face), IP40 (in enclosure)
-
Conformity Standards: IEC 60898-1, IEC 60947-2, CE, RoHS
2. Key Features A9F77106
-
High-performance circuit breaker offering reliable protection against short circuits and overloads
-
Compact design suitable for residential, commercial, and industrial panels
-
C curve tripping characteristic is ideal for general-purpose circuits with moderate inrush currents
-
Dual standard compliance (IEC 60898-1 & IEC 60947-2) allows usage in a wider range of applications
-
Long mechanical and electrical lifespan ensures durability and low maintenance
-
Easy installation on DIN rail with secure terminal connections
-
Compatible with Acti9 system accessories (auxiliary contacts, shunt trips, motorized controls, etc.)
-
Offers enhanced safety with protection against direct finger contact (IP20)
-
Visual indication of ON/OFF status and contact position
-
Halogen-free construction for reduced toxicity and improved fire safety
3. Applications
-
Suitable for protecting single-phase circuits in residential distribution boards
-
Used in commercial and industrial installations to protect lighting circuits, power sockets, or control systems
-
Ideal for branch circuits that feed individual loads such as HVAC units, water heaters, or motor starters
-
Commonly used in panelboards, motor control centers, and sub-distribution boards
-
Can be used as a main or supplementary circuit breaker in modular systems
-
Provides selective coordination when used with Acti9 series RCDs and other protection devices
-
Applicable in automation systems, building management systems, and control panels
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 6 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at <= 72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 IEC 60898-1 EN 60898-1 EN 60947-2 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | Trip indicator |
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| Height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Product weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.800 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 108.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.500 cm |
| Package 2 Width | 9.900 cm |
| Package 2 Length | 21.900 cm |
| Package 2 Weight | 1.356 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 15.421 kg |
| Warranty | 18 months |
|---|
Reviews (0)
Recommended for you
-
0
Schneider A9F87425 | Miniature circuit-breaker, Acti9 iC60H, 4P, 25 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87420 | Miniature circuit-breaker, Acti9 iC60H, 4P, 20 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-