Schneider A9F75332 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 32A, D curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Description
Schneider A9F75332 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 32A, D curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Schneider A9F75332 Description
This Acti9 iC60N is a low voltage miniature circuit breaker (MCB).
It is a 3P circuit breaker with 3 protected poles, 32A rated current and D tripping curve.
The rated short circuit breaking capacity goes up to 20kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard.
It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2.
This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit.
Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance.
Its fast closing mechanism independent of manual operation improves its service life.
It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles.
The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost.
The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm.
Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 78.5mm. The weight is 0.375kg.
According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure.
The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.
The Schneider A9F75332 is part of the Acti9 series, known for its advanced protection capabilities and reliable performance in electrical distribution. This series caters to both residential and commercial applications, ensuring optimal safety and efficiency.
Schneider A9F75332: Technical Specifications and Features
Technical Specifications:
- Product Range: Acti9
- Product Type: Miniature Circuit Breaker (MCB)
- Number of Poles: 3
- Rated Current: 32 A
- Tripping Curve: C-curve
- Breaking Capacity: 10 kA at 230/400V AC
- Rated Voltage: 230/400V AC
- Frequency: 50/60 Hz
- Standards: IEC/EN 60898-1
Key Features:
- Safety Indicators: VisiTrip indicators enable quick identification of tripped circuits, reducing downtime and facilitating faster maintenance.
- High Breaking Capacity: With a breaking capacity of 10 kA, the A9F75332 provides robust protection against short circuits and overloads.
- Ease of Installation: The modular design ensures easy installation on DIN rails, allowing for straightforward upgrades and replacements.
- Durability: Constructed with high-quality materials, the A9F75332 guarantees long-term performance and reliability.
- Compatibility: It is compatible with various Acti9 series accessories, such as auxiliary contacts and remote control units, enhancing its versatility.
- Eco-Friendly: Schneider Electric emphasizes sustainable practices, and the A9F75332 is designed with eco-friendly materials and processes.
Applications:
- Residential Buildings: Provides reliable protection for electrical circuits in homes, safeguarding against overloads and short circuits.
- Commercial Buildings: Ensures the safety and efficiency of electrical systems in offices, shops, and other commercial establishments.
- Industrial Settings: Suitable for small industrial applications requiring dependable circuit protection.
Benefits of Using Schneider A9F75332
- Enhanced Safety: Clear trip indicators and robust construction minimize the risk of electrical hazards.
- Cost-Effective Maintenance: Easy fault identification and straightforward replacement reduce maintenance costs and downtime.
- Versatility: Applicable in a wide range of settings, offering flexibility and adaptability.
- Longevity: High-quality construction ensures long-term reliability, minimizing the need for frequent replacements.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 32 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | D |
| Breaking capacity | 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60898-1 IEC 60947-2 EN 60947-2 IEC 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 12 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 125...180 V DC 10 kA 100 % conforming to EN 60947-2 - 125...180 V DC |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| net weight | 0.375 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 5.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 368.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 8.000 cm |
| Package 2 Width | 9.500 cm |
| Package 2 Length | 22.000 cm |
| Package 2 Weight | 1.529 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 44 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 17.400 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9F87432 | Miniature circuit-breaker, Acti9 iC60H, 4P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F77140 | Miniature circuit-breaker, Acti9 iC60N, 1P, 40 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.