Schneider A9K02410 | Acti9 K60N 4P – 10A – C curve 6000 A

1. Product Introduction: it circuit breaker is a four-pole circuit breaker designed to protect electrical circuits from overloads and short circuits. It is equipped with advanced features, including time-delay functionality and high inrush current resistance, making it suitable for use in various industrial and commercial applications.

2. Technical Specifications 

  • Rated Current: 10 Amps.
  • Number of Poles: Four-pole (4P).
  • Curve Type: C curve (ideal for circuits with high inrush currents, such as motors and equipment with large start-up loads).
  • Maximum Short-Circuit Breaking Capacity: 6000 Amps.
  • Electrical Rating: Provides protection against overloads and short circuits.
  • Voltage: Compatible with industrial voltage standards.
  • Applications: Designed for use in low-voltage electrical systems.
  • Protection Class: IP20 (suitable for industrial environments).

3. Features:

  • Overload Protection: Safeguards circuits from excessive current that could potentially cause damage.
  • Short-Circuit Protection: Protects electrical circuits from short-circuit conditions.
  • C Curve: Suitable for circuits with high inrush currents, such as electric motors and other industrial equipment.
  • Four-Pole Design: Provides protection for three-phase circuits with a neutral, ideal for more complex systems.
  • Easy Installation and Maintenance: The design ensures easy and quick installation, reducing downtime and maintenance efforts.
  • Long Durability: Engineered for long-lasting performance, even under high current conditions.
  • High Breaking Capacity: Can withstand up to 6000 A of short-circuit current, ensuring the protection of circuits in demanding environments.

4. Applications:

  • Industrial Electrical Protection: Used in industries that require protection against overloads and short circuits, including factories, power plants, and industrial electrical systems.
  • Commercial Buildings: Ideal for use in commercial buildings with complex electrical setups requiring high inrush current protection.
  • Motors and High-Load Equipment: Used in applications involving motors and equipment that require high starting currents, such as manufacturing machinery and HVAC systems.
  • Electrical Distribution Systems: Protects electrical distribution systems that include three-phase circuits with a neutral.

 

Additional information

brands

Schneider Electric

Specifications

Main
Device application Distribution
Range Acti9
product name Acti9 K60
Product or component type Miniature circuit-breaker
Device short name K60N
Poles description 4P
Number of protected poles 4
[In] rated current 10 A
network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilisation category Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60898-1
Standards EN/IEC 60898-1
Product certifications VDE
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 5...10 x In
[Ics] rated service breaking capacity 6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
Limitation class 3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage 440 V AC 50/60 Hz conforming to EN/IEC 60898-1
[Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60898-1
Contact position indicator No
control type Toggle
Local signalling Without
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Downside: biconnect
9 mm pitches 8
Height 81 mm
Width 72 mm
Depth 70 mm
Product weight 0.48 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 20000 cycles
Connections - terminals Tunnel type terminals (downstream) 0.5…35 mm² rigid
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
Earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
Pollution degree 2 conforming to IEC 60898-1
overvoltage category II
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -25…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.2 cm
Package 1 Width 7.08 cm
Package 1 Length 8.1 cm
Package 1 Weight 0.41 kg

Reviews (0)

Be the first to review “Schneider A9K02410 | Acti9 K60N 4P – 10A – C curve 6000 A”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare