Schneider A9N18359 | Acti9, Miniature circuit breaker (MCB), Acti9 C120N, 1P, 125A, C curve, 10000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Schneider A9N18359 | Acti9, Miniature circuit breaker (MCB), Acti9 C120N, 1P, 125A, C curve, 10000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Description
Schneider A9N18359 | Acti9, Miniature circuit breaker (MCB), Acti9 C120N, 1P, 125A, C curve, 10000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Technical Specifications
Electrical Specifications
-
Product Type: Miniature Circuit Breaker (MCB)
-
Series: Acti9 C120N
-
Number of Poles: 1P (Single-Pole)
-
Rated Current: 125A
-
Tripping Curve: C Curve (Trips at 5 to 10 times the rated current)
-
Breaking Capacity:
-
10,000A (10 kA) as per IEC/EN 60898-1
-
10 kA as per IEC/EN 60947-2
-
-
Voltage Rating: 230V AC
-
Frequency: 50/60 Hz
-
Mounting Type: DIN Rail
Design and Build
-
Compact and Modular Design: Saves space in electrical panels
-
Material: High-quality, flame-resistant plastic housing
-
Indicator Window: Displays ON/OFF status for quick circuit monitoring
-
IP Protection Rating: IP20 (Protected against solid objects larger than 12.5mm)
Connections and Interfaces
-
Terminal Type: Screw terminals for secure wiring connections
-
Connection Capacity: Supports various wire sizes for flexibility
-
Compatible with Acti9 Accessories: Can be integrated with auxiliary contacts, shunt trips, and Vigi earth leakage add-ons
Key Features
-
Reliable Overload and Short Circuit Protection
-
Ensures safe electrical operation by preventing excessive current flow.
-
-
C-Curve Tripping for Moderate Inrush Current Protection
-
Ideal for industrial machines, power distribution, and commercial loads.
-
-
High Breaking Capacity (10 kA)
-
Provides strong fault current protection, preventing damage to equipment and wiring.
-
-
1-Pole Configuration
-
Suitable for single-phase electrical circuits.
-
-
Compliant with International Standards
-
Certified as per IEC/EN 60898-1 and IEC/EN 60947-2, ensuring safety and performance.
-
-
Compact and Space-Saving Design
-
Easily integrates into electrical distribution boards and control panels.
-
-
Durable and Long-Lasting
-
Made with high-quality materials for extended service life.
-
-
Quick and Easy Installation
-
DIN rail mounting allows for fast and secure installation.
-
-
Indicator Window for Easy Monitoring
-
Provides visual indication of circuit breaker status (ON/OFF).
-
Applications
1. Industrial Electrical Installations
-
Used in factories, warehouses, and production facilities to protect high-power electrical circuits.
2. Commercial Buildings and Office Complexes
-
Ensures safe electrical distribution in malls, offices, hotels, and hospitals.
3. Renewable Energy Systems
-
Protects solar power systems, wind energy setups, and battery storage systems.
4. HVAC and Large Electrical Equipment
-
Ideal for heating, ventilation, and air conditioning (HVAC) systems and large motors.
5. Data Centers and IT Infrastructure
-
Safeguards server rooms and IT networks from electrical faults.
6. Power Distribution Panels
-
Essential for main electrical panels in industrial and commercial facilities.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | C120 |
|---|---|
| Range | Acti9 |
| Product name | C120 |
| Product or component type | Miniature circuit-breaker |
| Device short name | C120N |
| Device application | Distribution |
| poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 125 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Network frequency | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage | 380...415 V AC 50/60 Hz 125 V DC <= 144 V DC 12 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 130 V AC 50/60 Hz 12 V AC 50/60 Hz |
| Magnetic tripping limit | 5...10 x In |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC 2.25 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - <= 144 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 12 V AC 50/60 Hz 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz |
| Limitation class | 3 conforming to EN/IEC 60947-2 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| Mounting support | 35 mm symmetrical DIN rail |
| Comb busbar and distribution block compatibility | YES |
| 9 mm pitches | 3 |
| Height | 81 mm |
| Depth | 73 mm |
| Width | 27 mm |
| Net weight | 0.205 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 5000 cycles conforming to IEC 60947-2 |
| Locking options description | Handle sealable with cable diameter 0.7mm in OFF or ON position |
| Connections - terminals | Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible |
| Wire stripping length | 15 mm |
| Tightening torque | 3.5 N.m |
| Earth-leakage protection | Without |
| Standards | EN/IEC 60898-1 EN/IEC 60947-2 |
|---|---|
| Product certifications | EAC |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.500 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 194.700 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.500 cm |
| Package 2 Width | 9.500 cm |
| Package 2 Length | 33.000 cm |
| Package 2 Weight | 2.380 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 72 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 14.659 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews