Schneider A9V44463 | Vigi iC60 – earth leakage add-on block – 4P – 63A – 300mA – AC type
Schneider A9V44463 | Vigi iC60 – earth leakage add-on block – 4P – 63A – 300mA – AC type
Description
Schneider A9V44463 | Vigi iC60 – earth leakage add-on block – 4P – 63A – 300mA – AC type
Technical Specifications A9V44463
-
Product Code: A9V44463
-
Series: Vigi iC60
-
Device Type: Earth Leakage Add-on Block
-
Number of Poles: 4 (3 phases + neutral)
-
Rated Current (In): 63 A
-
Residual Operating Current (IΔn): 300 mA
-
Leakage Detection Type: Type AC (sinusoidal residual currents)
-
Rated Operational Voltage: 400 V AC
-
Rated Frequency: 50/60 Hz
-
Mounting Type: DIN rail (on iC60 MCBs)
-
Test Button: Yes
-
Degree of Protection: IP20 (front panel)
-
Standards: IEC 61008-1, IEC 60947-2
-
Mechanical Durability: > 5000 cycles
-
Electrical Endurance: > 2000 operations at rated load
Key Features
-
4-Pole Protection: Covers all three phases and neutral, ideal for three-phase installations.
-
High Current Rating: Rated at 63A, suitable for medium to high-load circuits.
-
300mA Sensitivity: Designed for indirect contact protection and fire prevention, rather than personal protection (which usually uses 30mA).
-
Type AC Leakage Detection: Handles sinusoidal AC leakage, appropriate for most general-purpose electrical systems.
-
Compatible with iC60 Breakers: Designed to attach directly to Schneider iC60 series circuit breakers.
-
Test Functionality: Integrated test button for routine maintenance and functionality checks.
-
Quick Mounting: Tool-less DIN rail mounting simplifies installation and upgrades.
Applications
The Schneider A9V44463 is suited for a wide range of use cases, especially in scenarios where earth fault protection is required but high leakage levels are permissible.
Industrial Applications
-
Suitable for factories, production lines, and heavy machinery setups where operational leakage may be higher than residential limits.
Fire Protection
-
The 300mA sensitivity allows detection of leakage currents that could cause thermal stress and lead to electrical fires, even if not harmful to humans.
Three-Phase Systems
-
Perfect for commercial buildings, large HVAC units, pumping stations, and three-phase distribution boards requiring residual current protection on all lines.
Panel Upgrades
-
Easy to add to existing iC60 breakers, offering a straightforward way to enhance safety without replacing the full distribution system
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Acti9 |
|---|---|
| Product or component type | Add-on residual current devices |
| Device short name | Vigi iC60 |
| Poles description | 4P |
| [In] rated current | 63 A |
| Earth-leakage sensitivity | 300 mA |
| earth-leakage protection time delay | Instantaneous |
| Earth leakage protection type | Type AC |
| Network type | AC |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 400 V AC 50/60 Hz conforming to EN 61009-1 400/415 V AC 50/60 Hz conforming to IEC 61009-1 conforming to IEC/EN 61009-2-1 |
| Standards | EN 61009-1 IEC 61009-1 |
| 9 mm pitches | 7 |
| device location in system | Outgoer |
|---|---|
| Residual current tripping technology | Voltage independent |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Range compatibility | Acti 9 Acti9 iC60 Acti 9 Acti9 Reflex iC60 |
| Product compatibility | Single terminal |
| local signalling | Trip indicator |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| Electrical connection to mcb | By screws |
| Comb busbar and distribution block compatibility | Bottom: YES |
| height | 91 mm |
| Width | 135 mm |
| Depth | 73.5 mm |
| Net weight | 0.245 kg |
| Connections - terminals | Tunnel type terminal downside for 1 cable(s) 1…35 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible with cable end |
| Wire stripping length | 14 mm for bottom connection |
| Tightening torque | 3.5 N.m bottom |
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
|---|---|
| Pollution degree | 3 conforming to IEC 60947-2 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to IEC 61009-1 |
| ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.6 cm |
| Package 1 Width | 12 cm |
| Package 1 Length | 14.7 cm |
| Package 1 Weight | 250 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 4.18 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94125 | Miniature circuit-breaker, Acti9 iC60L, 1P, 25 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
-
0
Schneider A9F87416 | Miniature circuit-breaker, Acti9 iC60H, 4P, 16 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87140 | Miniature circuit-breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.