Schneider ATS130N2D38LT | Altivar Soft Starter ATS130, 38A, 200 to 480V AC, control supply 24V DC
Schneider ATS130N2D38LT | Altivar Soft Starter ATS130, 38A, 200 to 480V AC, control supply 24V DC
Description
Schneider ATS130N2D38LT | Altivar Soft Starter ATS130, 38A, 200 to 480V AC, control supply 24V DC
Technical Specifications
Electrical Specifications
-
Rated Current: 38A
-
Supported Voltage: 200 to 480V AC
-
Control Supply Voltage: 24V DC
-
Frequency: 50/60 Hz
-
Supported Power: Depends on the voltage and current used, suitable for medium-capacity motors
Design and Build
-
Dimensions (W × H × D): Compact design for easy panel mounting
-
Weight: Relatively lightweight compared to other models in the same category
-
Material: Heat and corrosion-resistant for extended durability
-
Protection Rating (IP Rating): Designed to withstand industrial environments
Ports and Connections
-
Input and Output Ports: Compatible with PLC (Programmable Logic Controllers)
-
Control Interface: Easily programmable for various application needs
-
Supported Communication Protocols: Compatible with standard industrial communication systems
Key Features
-
Reduced Inrush Current
-
Limits the starting current surge when motors are powered on, protecting the electrical network and components.
-
-
Energy Efficiency Improvement
-
Reduces energy consumption during startup, lowering operating costs and enhancing system efficiency.
-
-
Motor Protection
-
Minimizes vibrations and mechanical stress on the motor, extending its lifespan and reducing maintenance needs.
-
-
Easy Installation and Programming
-
Compact design for easy integration into control panels, with user-friendly programming options.
-
-
Compatibility with Modern Control Systems
-
Can be integrated with PLC systems and smart industrial applications, making it ideal for advanced industrial setups.
-
-
Advanced Fault Protection
-
Equipped with safety features such as over-temperature protection, overvoltage and undervoltage protection, and phase failure detection.
-
Applications
1. Industrial Applications
-
Used in factories with large electric motors, such as production lines and material handling equipment.
-
Suitable for controlling pumps, compressors, and industrial fans, improving operational efficiency and reducing mechanical wear.
2. HVAC Systems
-
Ideal for heating, ventilation, and air conditioning systems, optimizing energy consumption and preventing sudden breakdowns.
3. Water Treatment Plants
-
Used to control pumps effectively, ensuring smooth water flow regulation while minimizing energy waste.
4. Conveyors and Lifting Systems
-
Can be implemented in conveyor belts and electric hoists, providing smooth control and preventing rapid wear of mechanical components.
5. Petrochemical and Mining Industries
-
Due to its durability, it is suitable for harsh environments such as mines and petrochemical plants, where motors require reliable and secure startup control.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Altivar Soft Starter ATS130 |
|---|---|
| Product or component type | Soft starter |
| product destination | Asynchronous motors |
| Product specific application | Simple machine |
| Device short name | ATS130 |
| Network number of phases | 3 phases |
| Utilisation category | AC-53A |
| Ue power supply voltage | 200...480 V - 15...10 % |
| power supply frequency | 50...60 Hz +/- 5 Hz |
| [Ie] rated operational current | 38 A in line (at <40 °C) |
| Service factor at Ie | 100 |
| Torque control | False |
| IP degree of protection | IP20 |
| Motor power kW | 11 kW at 230 V normal duty 18.5 kW at 400 V normal duty 22 kW at 440 V normal duty |
| Motor power hp | 10 hp at 200 V normal duty 10 hp at 208 V normal duty 10 hp at 230 V normal duty 25 hp at 460 V normal duty |
| Overload current profile | 300 % Ie for 5 s |
|---|---|
| On-load factor | 70 % |
| Operating cycles/hour | 50 cyc/h |
| Minimum motor current | 20 % Ie |
| Device connection | In line |
| [Us] control circuit voltage | 24 V DC +/- 10 % |
| Control power | 21.6 W starting and stopping 3 W steady state |
| Integrated motor overload protection | False |
| Protection type | Phase failure: mains Thermal protection: starter Bypass error: starter Control voltage Us: starter |
| Rated current pwr loss specification | 38.0 A |
| Power loss static current independent | 3 W |
| Power loss per device current dependent | 7 W |
| Power loss during starting | 220 W 300 % Ie |
| Standards | EN/IEC 60947-4-2 UL 60947-4-2 IEC 60664-1 |
| Product certifications | CE UKCA CCC RCM EAC |
| Marking | CE CCC UKCA RCM EAC |
| [Uc] control circuit voltage | 24 V DC |
| Discrete input number | 3 |
| Discrete input type | (DI) digital input, 10 kOhm (DI2) digital input, 10 kOhm (BOOST) digital input, 10 kOhm |
| Input compatibility | Discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Discrete input logic | Digital input at State 0: 0...< 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA |
| Relay output number | 1 |
| Relay output type | Relay outputs R1A, R1C NO |
| Minimum switching current | 2.5 mA at 24 V DC for relay outputs |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cycles On resistive load for relay outputs : 1 A 30 V DC 400000 cycles On inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cycles On inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Discrete output number | 1 |
| Discrete output type | Non programmable digital output DQ1 <= 30 V 200 mA |
| Display type | 1 LED (green) for control power energized 1 LED (yellow and red) for motor operation phases, errors |
| Display screen available | False |
| Operating position | Vertical +/- 30 degree |
| Height | 166 mm |
| Width | 55 mm |
| Depth | 165 mm |
| Net weight | 1.3 kg |
| Suitable for mounting onto standard rails | True |
| Function available | Deceleration voltage ramp Boost |
| internal bypass | True |
| material declaration | True |
| Pollution degree | Level 2 |
|---|---|
| environmental class (during operation) | Without salt mist: 3C3 conforming to IEC 60721-3-3 3S3 conforming to IEC 60721-3-3 |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Ui] rated insulation voltage | 480 V |
| Electromagnetic compatibility | Conducted and radiated emissions level B conforming to IEC 60947-4-2 Short voltage interruptions level 3 conforming to IEC 61000-4-11 Electrostatic discharge level 2 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 1 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 2 conforming to IEC 61000-4-4 Oscillatory waves immunity level 3 conforming to IEC 61000-4-12 Voltage/current impulse level 2 conforming to IEC 61000-4-5 Conducted disturbances, induced by radiofrequency fields level 1 conforming to IEC 61000-4-6 |
| Ambient air temperature for operation | -10…40 °C (without derating) 40…60 °C (with current derating 1.5 % per °C) |
| ambient air temperature for storage | -25…70 °C |
| Ambient air transport temperature | -40…70 °C |
| Operating altitude | 0...1000 m without derating 1000...4000 m 1 % per 100 m |
| Relative humidity | 5…95 % non condensing without dripping water conforming to IEC 60068-2-3 |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Maximum acceleration under vibratory load (during transport) | 10 m/s² at 9...200 Hz |
| Maximum deflection under vibratory load (during operation) | 3 mm at 2-9 Hz |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under shock impact (during operation) | 100 m/s² at 11 ms |
| Maximum acceleration under shock load (during storage) | 100 m/s² at 11 ms |
| Maximum acceleration under shock load (during transport) | 100 m/s² at 11 ms |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.300 cm |
| Package 1 Width | 27.000 cm |
| Package 1 Length | 27.500 cm |
| Package 1 Weight | 1.510 kg |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 69.500 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider NSYSFD2010 | Spacial SF plain door – 2000×1000 mm
Schneider NSYEC86 | Plain cable gland plate, PanelSeT SFN, PanelSeT SF, for electrical enclosure W800 D600mm, fixed by clips
Schneider NSYSFD206 | Spacial SF plain door – 2000×600 mm
-
0
Schneider NSYSM2012602D | PanelSeT SM compact enclosure without mounting plate – 2000x1200x600 mm
Schneider NSYCRNG128300 | Spacial CRNG plain door w/o mount.plate. H1200xW800xD300 IP66 IK10 RAL7035
-
0
Reviews