Schneider C100N320FM | Circuit breaker, ComPacT NS1000N, 50kA at 415VAC, 3P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A
Schneider C100N320FM | Circuit breaker, ComPacT NS1000N, 50kA at 415VAC, 3P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A
Description
Schneider C100N320FM | Circuit breaker, ComPacT NS1000N, 50kA at 415VAC, 3P, fixed, manually operated, MicroLogic 2.0 control unit, 1000A
The Schneider Electric C100N320FM is a circuit breaker from the ComPacT NS1000N series. It is designed for industrial and tertiary applications, featuring a rated current of 1000A and a breaking capacity of 50kA at 415VAC. It is a 3-pole, fixed, manually operated breaker, equipped with the MicroLogic 2.0 control unit for comprehensive electrical monitoring.
Key Features of Schneider Electric C100N320FM
- Rated Current: 1000A, making it suitable for large-scale electrical systems.
- Breaking Capacity: 50kA at 415V AC, ensuring reliability during fault conditions.
- Control Unit: The MicroLogic 2.0 unit provides advanced protection, metering, and communication functions.
- Manual Operation: Allows operators to manually control the breaker when needed.
- Fixed Installation: Designed for fixed installation in switchboards or distribution panels.
Applications of Schneider C100N320FM
This breaker is ideal for protecting electrical circuits in industrial, commercial, and tertiary sector applications. It can be used in systems that require high current handling and advanced protection functions.
The ComPacT NS series is known for its robustness and flexibility, making it a trusted solution for complex electrical networks. It combines efficient operation with a high level of safety, meeting the needs of engineers and industrial professionals.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT |
|---|---|
| product name | ComPacT NS new generation |
| Range of product | ComPacT NS630b...1600 new generation |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Number of poles | 3P |
| Protected poles description | 3D |
| (In) rated current up to 65 °C | 1000 A at 50 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category B |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | MicroLogic 2.0 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LI |
| Control type | Manually operated |
| Mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Icw] rated short-time withstand current | 19.2 kA 1 s conforming to IEC 60947-2 |
| Mechanical durability | 10000 cycles |
| Electrical durability | 2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2 |
| Power losses | 22 W |
| Mounting support | Backplate |
| Upside connection | Front |
| Downside connection | Front |
| Connection pitch | 70 mm |
| Protection type | L : for overload protection (long time) I : for instantaneous short-circuit protection |
| Trip unit rating | 1000 A at 50 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 0.4...1 x In |
| Long-time protection delay adjustment type tr | Adjustable 9 settings |
| [tr] long-time protection delay adjustment range | 12.5…600 s at 1.5 x Ir 0.5…24 s at 6 x Ir 0.7…16.6 s at 7.2 x Ir |
| Thermal memory | 20 mn |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 1.5...10 x Ir |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Auxiliary contact composition | 1 NO/NC |
| Local signalling | 4 LEDs (red) for fault indication 1 LED (yellow) for overload |
| Width (W) | 210 mm |
| Height (H) | 327 mm |
| Depth (D) | 147 mm |
| Product weight | 14 kg |
| Standards | EN/IEC 60947-2 |
|---|---|
| Product certifications | IECEE CB Scheme |
| Pollution degree | 3 conforming to IEC 60947 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to EN 50102 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 30.000 cm |
| Package 1 Width | 40.000 cm |
| Package 1 Length | 60.000 cm |
| Package 1 Weight | 12.442 kg |
Reviews (0)
Recommended for you
Schneider A9N61515 | miniature circuit breaker – C60H – 1 pole – 32 A – C curve
Schneider A9N61508 | miniature circuit breaker – C60H – 1 pole – 10 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.