Schneider C10F32D100 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d
Description
Schneider C10F32D100 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d
Schneider C10F32D100 Description
This ComPacT NSX100F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.
It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.
The operational voltage is 690VAC 50/60Hz.
This product embeds an electronic MicroLogic 2.2 trip unit, with 100A rating.
MicroLogic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.
This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.
Introduction
Schneider Electric is a global leader in energy management and automation, providing innovative and reliable products for various applications. The Schneider C10F32D100 is one of their high-quality circuit breakers, designed to offer excellent protection and performance. This article will cover the features, technical specifications, applications, and overall value of the Schneider C10F32D100, giving you a comprehensive understanding of this essential device.
Overview of the Schneider C10F32D100
The Schneider C10F32D100 is a miniature circuit breaker (MCB) known for its reliability and efficiency. It is designed to protect electrical circuits from overloads and short circuits, ensuring the safety and functionality of electrical systems.
Primary Features
- Single-Pole Protection: Offers efficient protection for individual circuits.
- High Breaking Capacity: Can interrupt high fault currents, ensuring system safety.
- Compact Design: Fits easily into standard electrical panels, saving space.
- Durable Construction: Made from high-quality materials for long-lasting performance.
- Easy Installation: User-friendly design facilitates quick and hassle-free installation.
Technical Specifications
Electrical Specifications
- Rated Voltage: 230/400V AC
- Rated Current: 100A
- Breaking Capacity: 10kA according to IEC/EN 60898-1
- Tripping Curve: Type F (10-20 times the rated current)
Mechanical Specifications
- Dimensions: 81mm x 18mm x 70mm
- Weight: 0.150 kg
- Mounting: DIN rail.
Pre-Installation Checklist
- Verify that the main power supply is turned off.
- Ensure compatibility with the electrical panel.
- Gather necessary tools and protective equipment.
Step-by-Step Installation Process
- Power Down: Turn off the main power supply to avoid electrical hazards.
- Mount the Breaker: Secure the C10F32D100 to the DIN rail in the electrical panel.
- Wire Connections: Connect the input and output wires to the appropriate terminals, ensuring tight connections.
- Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
- Finalize Installation: Organize and secure any loose wires and close the panel.
Applications and Usage
The versatility of the Schneider C10F32D100 makes it suitable for various applications.
Industrial Applications
Ideal for protecting motor circuits and transformers in industrial settings.
The Schneider C10F32D100 is engineered for high performance and energy efficiency.
Performance Metrics
- Response Time: Quick tripping response to overloads and short circuits.
- Reliability: Consistent protection with minimal downtime.
Energy Efficiency Considerations
The design minimizes energy loss, contributing to the overall efficiency of the electrical system.
Safety Features
Schneider Electric prioritizes safety, and the C10F32D100 includes several built-in safety features.
Compliance with Safety Standards
The C10F32D100 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.
Built-In Safety Mechanisms
- Overload Protection: Automatically trips to prevent overheating and potential fires.
- Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.
Maintenance and Troubleshooting
Regular maintenance ensures the continued effective operation of the Schneider C10F32D100.
Regular Maintenance Practices
- Visual Inspection: Regularly check for signs of wear or damage.
- Testing: Periodically test the circuit breaker to ensure it functions correctly.
- Cleaning: Keep the breaker and surrounding area clean and free of dust.
Common Troubleshooting Tips
- Frequent Tripping: This may indicate an overload condition; verify that the connected load is within the breaker’s rated capacity.
- Loose Connections: Check and tighten any loose wire connections to prevent arcing and potential faults.
Customer Support and Warranty
Schneider Electric offers robust customer support and warranty services for the C10F32D100.
Warranty Coverage
The C10F32D100 comes with a manufacturer’s warranty covering defects in materials and workmanship for a specified period.
Customer Support Options
- Technical Support: Available via phone and email for assistance with installation, troubleshooting, and maintenance.
- Online Resources: Access to manuals, FAQs, and video tutorials on the Schneider Electric website.
Pros and Cons
Advantages of the C10F32D100
- Reliable Protection: Effective protection against overloads and short circuits.
- Durable Construction: High-quality materials ensure longevity and reliability.
- Easy Installation: User-friendly design simplifies the installation process.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | MicroLogic 2.2 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 4.7 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir |
| thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1500 A |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| net weight | 2.05 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 1.826 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 13.166 kg |
Reviews