Schneider C10F42D040 | Circuit breaker, ComPacT NSX100F, 36kA/415VAC, 4 poles, MicroLogic 2.2 trip unit 40A
Description
Schneider C10F42D040 | Circuit breaker, ComPacT NSX100F, 36kA/415VAC, 4 poles, MicroLogic 2.2 trip unit 40A
Schneider C10F42D040 Description
This Compact NSX100F is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity.
It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz.
This product embeds an electronic Micrologic 2.2 trip unit, with 40A rating.
Micrologic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.
This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
Compact NSX100F is part of Schneider Electric EcoStruxure Power architecture.
Introduction
Schneider Electric is renowned for its innovative solutions in energy management and automation. The Schneider C10F42D040 is a high-performance circuit breaker designed to offer robust protection for a variety of electrical applications, ensuring safety and reliability.
Overview of the Schneider C10F42D040
The Schneider C10F42D040 is a miniature circuit breaker (MCB) that provides efficient and reliable protection by automatically disconnecting electrical circuits during overloads or short circuits, safeguarding electrical installations and preventing potential damage or fire hazards.
Basic Description
- Product Type: Miniature Circuit Breaker (MCB)
- Model Number: C10F42D040
- Pole: 2P (two poles)
- Current Rating: 40A
Key Features
- High Breaking Capacity: Designed to handle a wide range of applications with varying load requirements.
- Compact Design: Space-efficient and easy to install in standard electrical panels.
- Durable Construction: Made from high-quality materials for long-lasting reliability.
- User-Friendly Installation: Simplified mounting process for quick and easy installation.
Technical Specifications
Electrical Specifications
- Rated Current: 40A
- Number of Poles: 2
- Breaking Capacity: High capacity to effectively protect against overloads and short circuits.
- Operating Voltage: Suitable for both low and medium voltage applications.
Mechanical Specifications
- Dimensions: Standard size for seamless integration into existing systems.
- Weight: Lightweight yet robust design for easy handling and installation.
- Mounting Type: DIN rail or surface mounting for versatile installation options.
Pre-Installation Checklist
- Verify that the main power supply is turned off.
- Ensure the circuit breaker is compatible with the electrical panel and application.
- Gather all necessary tools and safety equipment.
Step-by-Step Installation Process
- Turn Off Power: Ensure the main power supply is completely shut off.
- Mount the Breaker: Secure the C10F42D040 onto the DIN rail or surface mount as required.
- Connect Wiring: Attach the input and output wires to the appropriate terminals, ensuring secure connections.
- Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
- Complete Installation: Organize and secure any loose wires and close the panel.
Applications and Usage
The Schneider C10F42D040 is suitable for a variety of applications, providing reliable protection in different environments.
Industrial Applications
- Protects motor circuits, transformers, and other industrial equipment from electrical faults.
Commercial Applications
- Ensures the safety of electrical systems in commercial buildings, such as offices and retail spaces.
Residential Applications
- Provides reliable protection for household electrical circuits, safeguarding appliances and other devices.
Compatibility and Integration
The Schneider C10F42D040 is designed for easy integration with various electrical systems.
Compatible Systems and Devices
- Electrical Panels: Suitable for installation in standard residential, commercial, and industrial panels.
- Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.
Maintenance and Troubleshooting
Regular maintenance is essential to ensure the continued reliable operation of the Schneider C10F42D040.
Regular Maintenance Practices
- Visual Inspections: Regularly check for signs of wear, damage, or overheating.
- Functional Testing: Periodically test the breaker to ensure it operates correctly.
- Cleaning: Keep the breaker and surrounding area free from dust and debris.
Common Troubleshooting Tips
- Frequent Tripping: Check for overload conditions or potential short circuits; verify that the connected load is within the breaker’s rated capacity.
- Loose Connections: Inspect and tighten any loose wire connections to prevent arcing and faults.
Customer Support and Warranty
Schneider Electric offers robust customer support and warranty services for the C10F42D040.
Warranty Coverage
- Manufacturer’s Warranty: Covers defects in materials and workmanship for a specified period, providing peace of mind.
Customer Support Options
- Technical Support: Available via phone and email for installation, troubleshooting, and maintenance assistance.
- Online Resources: Access manuals, FAQs, and video tutorials on the Schneider Electric website.
Pros and Cons
Advantages of the C10F42D040
- Reliable Protection: Effective protection against overloads and short circuits.
- Durable Construction: Made with high-quality materials for long-term reliability.
- Compact and Lightweight: Easy to install in various electrical panels.
Potential Limitations
- Cost: May be higher priced compared to some competitors.
- Limited to Certain Applications: Primarily designed for use in low to medium voltage applications.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 4D 3D + N/2 3D |
| Neutral position | Left |
| [In] rated current | 40 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | MicroLogic 2.2 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 1.34 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
| Trip unit rating | 40 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 18...40 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir |
| Neutral protection settings | 0.5 x Ir (3D + N/2) 1 x Ir (4D) No protection (3D) |
| thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| net weight | 2.4 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.5 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 19.6 cm |
| Package 1 Weight | 2.398 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 5.174 kg |
Reviews