Schneider CAD32M7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V – 220 V AC standard coil
Description
Schneider CAD32M7 | TeSys D control relay – 3 NO + 2 NC – <= 690 V – 220 V AC standard coil
Schneider CAD32M7 Description
Introduction to Schneider CAD32M7
it is a cutting-edge electrical component designed to enhance automation processes in various industries. Understanding its description is crucial for professionals and enthusiasts alike who seek to optimize their systems for efficiency and reliability.
Overview
it boasts a plethora of features and specifications that cater to the diverse needs of modern automation systems. Its robust design and advanced functionality make it a preferred choice for industrial applications worldwide.
Detailed Description
Physical Characteristics
it is compact yet sturdy, making it suitable for installation in tight spaces without compromising on durability. Its sleek design ensures seamless integration into existing setups.
Electrical Specifications
With precise electrical specifications, it ensures optimal performance in various operating conditions. Its high-quality components guarantee stable functionality, even in demanding environments.
Functionality and Operation
it offers intuitive operation, thanks to its user-friendly interface and advanced control features. Its versatile design allows for seamless integration with other components, enhancing overall system efficiency.
Advantages
it provides several advantages to users, including:
- Efficiency improvements: By streamlining automation processes, the Schneider CAD32M7 helps organizations boost productivity and reduce downtime.
- Cost-effectiveness: Its reliable performance and low maintenance requirements translate to long-term cost savings for businesses.
- Reliability and durability: Built to withstand harsh operating conditions, the Schneider CAD32M7 ensures uninterrupted operation, even in challenging environments.
Potential Applications
it finds applications in various industries, including:
- Industrial automation: From manufacturing facilities to warehouses, the Schneider CAD32M7 enhances process efficiency and productivity.
- Building management systems: In commercial buildings and residential complexes, the Schneider CAD32M7 contributes to energy savings and comfort optimization.
- Power distribution systems: By facilitating precise control and monitoring, the Schneider CAD32M7 improves the reliability and safety of power distribution networks.
Importance of Choosing
Selecting it offers several benefits, including:
- Quality assurance: Schneider Electric is renowned for its commitment to quality, ensuring that the CAD32M7 meets the highest standards of performance and reliability.
- Compatibility with existing systems: it seamlessly integrates with a wide range of automation platforms, allowing for easy upgrades and expansions.
- Long-term benefits: Investing in the Schneider CAD32M7 guarantees long-term returns, thanks to its durability, efficiency, and compatibility with future technologies.
Comparison with Similar Products
Compared to other similar products in the market,it stands out due to:
- Its advanced features and specifications
- Its reputation for reliability and performance
- Its comprehensive support and service options
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys TeSys Deca |
|---|---|
| Product name | TeSys CAD |
| Product or component type | Control relay |
| Device short name | CAD |
| Contactor application | Control circuit |
| Utilisation category | DC-13 AC-14 AC-15 |
|---|---|
| Pole contact composition | 3 NO + 2 NC |
| [Ue] rated operational voltage | <= 690 V AC 25...400 Hz |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 100 A - 1 s 120 A - 500 ms 140 A - 100 ms |
| Associated fuse rating | 10 A gG conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1 |
| Mounting support | Plate Rail |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end |
| Tightening torque | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Operating time | 12...22 ms coil energisation and NO closing 4...12 ms coil de-energisation and NO opening 4...19 ms coil energisation and NC opening 6...17 ms coil de-energisation and NC closing |
| Mechanical durability | 30 Mcycles |
| Maximum operating rate | 180 cyc/mn |
| Inrush power in VA | 70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Non-overlap time | 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 84 mm |
| Net weight | 0.58 kg |
| Standards | EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1 |
|---|---|
| Product certifications | CB CCC UL CSA EAC CE UKCA |
| IP degree of protection | IP2X front face conforming to VDE 0106 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -40…60 °C 60…70 °C with derating |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 0...3000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 9.200 cm |
| Package 1 Length | 11.200 cm |
| Package 1 Weight | 351.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.460 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 160 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 68.300 kg |
| Warranty | 18 months |
|---|