Description

Schneider EZC100H3080 | circuit breaker Easypact EZC100H – TMD – 80 A – 3 poles 3d

The Schneider EZC100H3080 is a molded case circuit breaker (MCCB) from the EasyPact EZC100H range. It offers reliable protection for electrical installations with an 80 A current rating, utilizing a thermal-magnetic (TMD) trip unit. Engineered for industrial and commercial environments, this breaker ensures safety, performance, and ease of installation.

 Technical Specifications

  • Model: EZC100H3080

  • Series: EasyPact EZC100H

  • Frame Size: 100 A

  • Rated Current (In): 80 A

  • Poles: 3P (Three poles)

  • Trip Unit Type: TMD (Thermal-Magnetic, fixed settings)

  • Rated Operational Voltage (Ue): Up to 415 V AC

  • Rated Insulation Voltage (Ui): 690 V AC

  • Ultimate Breaking Capacity (Icu): Up to 36 kA at 415 V AC

  • Mounting Type: Fixed

  • Connection Type: 3D (Three-pole direct connection)

  • Standard Compliance: IEC 60947-2

 Features

  • Overload and Short-Circuit Protection

    • Thermal trip for long-time overloads

    • Magnetic trip for short-circuit conditions

  • High Performance Breaking

    • Designed to operate safely under fault conditions with high breaking capacity

  • Compact & Robust Design

    • Saves panel space while ensuring mechanical durability

  • Ease of Installation

    • Direct connections and simple mounting for fast integration

 Applications

  • Low-voltage distribution systems

  • Panel boards and switchboards

  • Industrial machinery and motor protection

  • HVAC systems

  • Commercial electrical infrastructure

The Schneider EZC100H3080 is a dependable choice for 80 A circuit protection, ensuring operational safety and long-term durability in electrical systems. It is particularly well-suited for installations where space-saving, performance, and protection are key priorities.

Additional information

brands

Schneider Electric

Specifications

Main
Range of product EasyPact
Product or component type Circuit breaker
Device short name Easypact EZC100H
circuit breaker name Easypact EZC100H
Device application Distribution
Poles description 3P
Protected poles description 3t
Network type DC AC
Network frequency 50/60 Hz
[In] rated current 80 A at 40 °C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Breaking capacity code H
Breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 80 A at 50 °C
Protection type Overload protection Short-circuit protection
Pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Complementary
control type Toggle
Mounting mode Fixed
mounting support Backplate
Upside connection Front
downside connection Front
Mechanical durability 8500 cycles
Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch 25 mm
local signalling Positive contact indication
Neutral protection setting Without protection
earth-leakage protection Without
height 130 mm
Width 75 mm
Depth 60 mm
Environment
Standards GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -35…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.5 cm
Package 1 Width 8.5 cm
Package 1 Length 14.0 cm
Package 1 Weight 820.0 g
Unit Type of Package 2 S02
Number of Units in Package 2 12
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 10.295 kg
Unit Type of Package 3 PAL
Number of Units in Package 3 384
Package 3 Height 80.0 cm
Package 3 Width 120.0 cm
Package 3 Length 384.0 cm
Package 3 Weight 323.328 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider EZC100H3080 | circuit breaker Easypact EZC100H – TMD – 80 A – 3 poles 3d”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare