Schneider GV3P18 | Motor circuit breaker, TeSys GV3, 3P, 12-18 A, thermal magnetic, EverLink terminals
Schneider GV3P18 | Motor circuit breaker, TeSys GV3, 3P, 12-18 A, thermal magnetic, EverLink terminals
Description
Schneider GV3P18 | Motor circuit breaker, TeSys GV3, 3P, 12-18 A, thermal magnetic, EverLink terminals
Specifications:
- Model: Schneider GV3P18
- Series: TeSys GV3
- Number of Poles: 3P (Three Poles)
- Current Range: 12-18A
- Protection Type: Thermal-Magnetic
- Connection Type: EverLink Terminals
- Voltage Rating: Up to 690V AC
- Protection Rating: IP20
- Breaking Capacity: 100 kA at 400V AC
- Operating Temperature: -20°C to +55°C
Features:
Reliable Motor Protection: Provides thermal protection against overload and magnetic protection against short circuits.
Compact Design: Ideal for installation in control panels while saving space.
EverLink Technology: Ensures secure and stable wiring connections, reducing the need for re-tightening.
Easy Installation & Operation: Can be mounted on DIN rails or fixed using screws.
Compatible with Automation & Control Systems: Can be integrated with TeSys accessories and motor control devices.
Applications:
Protecting electric motors from overloads and short circuits.
Used in industrial applications such as pumps, fans, and compressors.
Suitable for electrical control panels and industrial machinery.
Ensures effective protection in commercial and infrastructure sectors.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys Deca |
|---|---|
| product name | TeSys GV3 |
| Product or component type | Motor circuit breaker |
| Device short name | GV3P |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Poles description | 3P |
|---|---|
| network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-4-1 |
| Motor power kW | 7.5 kW at 400/415 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz 15 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| control type | Rotary handle |
| [In] rated current | 18 A |
| Thermal protection adjustment range | 12…18 A conforming to IEC 60947-4-1 |
| Magnetic tripping current | 252 A |
| [Ith] conventional free air thermal current | 18 A conforming to IEC 60947-4-1 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 8 W |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles for AC-3 at 415 V In |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Tightening torque | 5 N.m - on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) |
| Mounting position | Horizontal Vertical |
| Width | 55 mm |
| Height | 132 mm |
| Depth | 136 mm |
| Product weight | 0.96 kg |
| Colour | Dark grey |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ |
|---|---|
| Product certifications | CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV ABS DNV-GL UKCA |
| IK degree of protection | IK09 enclosure |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 15 Gn for 11 ms contactor open Shocks: 30 Gn for 11 ms contactor closed Vibrations: 4 Gn, 5...300 Hz |
| Operating altitude | 3000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 16.000 cm |
| Package 1 Length | 14.500 cm |
| Package 1 Weight | 996.000 g |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 60 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 72.760 kg |
| Warranty | 18 months |
|---|
Reviews (0)
Recommended for you
Schneider NSYBP208 | Spacial SF rear panel external fixing – 2000×800 mm
Schneider NSYSFV20 | Set of 4 vertical uprights for Spacial SF enclosure. Height: 2000 mm. RAL 7035.
Schneider NSYCRNG128300 | Spacial CRNG plain door w/o mount.plate. H1200xW800xD300 IP66 IK10 RAL7035
-
0
Reviews
There are no reviews yet.