Schneider GV4AS287 | Voltage release, TeSys GV4, MX coil, 220 to 240VAC 50Hz, 208 to 277VAC 60Hz
Description
Schneider GV4AS287 | Voltage release, TeSys GV4, MX coil, 220 to 240VAC 50Hz, 208 to 277VAC 60Hz
Schneider GV4AS287 | Voltage Release, TeSys GV4, MX Coil, 220–240VAC 50Hz / 208–277VAC 60Hz
The Schneider GV4AS287 is a voltage release accessory (MX coil) designed for TeSys GV4 motor circuit breakers. This module enables remote tripping of the circuit breaker via an external control signal, enhancing safety and automation capabilities in electrical panels.
General Information:
-
Brand: Schneider Electric
-
Series: TeSys GV4
-
Model: GV4AS287
-
Product Type: Voltage release (MX coil)
-
Control Voltage Range:
-
220–240 V AC at 50 Hz
-
208–277 V AC at 60 Hz
-
-
Function: Remote tripping of the GV4 circuit breaker
Key Features:
-
Enables electrical tripping of GV4 breakers from remote locations
-
Wide voltage range for flexible installation
-
Compatible with industrial AC control systems (50/60Hz)
-
Compact and easily integrated into breaker units
-
High reliability and quick response for emergency tripping
Technical Specifications:
-
Mounting Location: Inside the GV4 circuit breaker
-
Electrical Life: High number of operations
-
Standard Compliance: IEC 60947-2
-
Environmental Rating: Suitable for industrial conditions
-
Operating Temperature: -25°C to +70°C
Applications:
-
Emergency stop systems
-
Remote control panels
-
Industrial automation and process control
-
Machine and motor protection setups
-
Distribution boards in commercial or industrial facilities
Benefits:
-
Enhances operator safety with remote trip function
-
Supports centralized electrical control
-
Simplifies integration into safety circuits
-
Durable and dependable in demanding environments
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys |
|---|---|
| Device short name | MX |
| Product or component type | Voltage release |
| Device application | Control |
| Range compatibility | TeSys TeSys GV4 TeSys TeSys BV4 |
| Voltage release type | Shunt trip release |
| [Uc] control circuit voltage | 277 V AC 60 Hz 220...240 V AC 50 Hz 208...240 V AC 60 Hz |
| [Ui] rated insulation voltage | 277 V conforming to IEC 60947-1 |
|---|---|
| Threshold tripping voltage | 0.7...1.1 Un failsafe opening < 0.7 Un possible opening |
| impulse duration | >= 20 ms |
| Mounting mode | Internal mounting |
| Maximum inrush power in VA | 6 VA |
| Maximum hold-in power consumption in VA | 10 VA |
| Mechanical durability | 20000 cycles |
| Operating time | < 50 ms |
| Connections - terminals | Spring terminals 1 0.5…1.5 mm² - cable stiffness: flexible without cable end |
| Wire stripping length | 8 mm |
| Quantity per set | Set of 1 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.5 cm |
| Package 1 Width | 8.5 cm |
| Package 1 Length | 6.1 cm |
| Package 1 Weight | 42.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 8.8 cm |
| Package 2 Width | 12.9 cm |
| Package 2 Length | 18.5 cm |
| Package 2 Weight | 0.5 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 60 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 3.441 kg |
Reviews