Description

Schneider GV4LE03N | Motor circuit breaker, TeSys GV4, 3P, 3.5 A, Icu 50 kA, magnetic, EverLink terminals

TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)

Schneider GV4LE03N?

The Schneider GV4LE03N is a robust circuit breaker designed to provide comprehensive protection in various electrical systems. Known for its reliability and efficiency, this model is a part of Schneider Electric’s extensive range of circuit protection devices.

1.2 Importance of Circuit Breakers

Circuit breakers are critical components in electrical systems. They prevent damage caused by overcurrent, short circuits, and electrical faults, ensuring the safety of both the equipment and the users.

2. Overview of Schneider Electric

2.1 Company History

Schneider Electric has a rich history dating back to the 19th century. Founded in 1836, the company has grown into a global leader in energy management and automation, offering innovative solutions across various industries.

2.2 Innovation in Electrical Solutions

Schneider Electric is renowned for its commitment to innovation. The company continuously develops cutting-edge products that enhance efficiency, safety, and sustainability in electrical management.

3. Detailed Description of Schneider GV4LE03N

3.1 Technical Specifications

The Schneider GV4LE03N features a compact design with a rated current of 0.25-32 A and a breaking capacity of up to 70 kA at 415 V AC. It is designed to operate within a temperature range of -25 to 70°C, making it suitable for diverse environments.

3.2 Key Features

  • Adjustable Thermal-Magnetic Trip Unit: This feature allows for precise adjustment of the trip settings, ensuring optimal protection.
  • Compact Design: The compact size makes it easy to integrate into various electrical systems.
  • High Breaking Capacity: With a high breaking capacity, it can handle significant electrical faults without compromising performance.
  • Wide Range of Accessories: Various accessories are available to enhance functionality and ease of installation.

3.3 Advantages

The GV4LE03N offers several advantages, including enhanced protection, easy installation, and minimal maintenance requirements. Its reliability and robust performance make it a preferred choice for many applications.

4. Applications of Schneider GV4LE03N

4.1 Industrial Use

In industrial settings, the GV4LE03N is used to protect machinery and equipment from electrical faults, ensuring continuous operation and safety.

4.2 Commercial Use

Commercial buildings benefit from the GV4LE03N’s ability to manage and protect electrical systems, reducing the risk of outages and equipment damage.

4.3 Residential Use

While primarily designed for industrial and commercial use, the GV4LE03N can also be used in residential settings where high performance and reliability are required.

5. Installation and Setup

5.1 Pre-Installation Requirements

Before installing the GV4LE03N, ensure that you have all the necessary tools and accessories. Check the electrical system’s specifications to match the breaker’s requirements.

5.2 Step-by-Step Installation Guide

  1. Turn Off Power: Ensure the power supply is completely shut off to avoid any electrical hazards.
  2. Mount the Breaker: Securely mount the GV4LE03N in the designated panel or enclosure.
  3. Connect Wires: Carefully connect the input and output wires according to the wiring diagram.
  4. Adjust Settings: Set the thermal-magnetic trip unit as per the system requirements.
  5. Power On: Restore power and test the breaker to ensure it functions correctly.

5.3 Safety Precautions

Always follow safety guidelines when installing electrical equipment. Wear appropriate protective gear and ensure the area is dry and free of conductive materials.

6. Maintenance and Troubleshooting

6.1 Regular Maintenance Tips

  • Inspect Regularly: Perform routine inspections to check for any signs of wear or damage.
  • Clean Components: Keep the breaker and its components clean from dust and debris.
  • Test Functionality: Regularly test the breaker to ensure it operates correctly under load conditions.

6.2 Common Issues and Solutions

  • Nuisance Tripping: If the breaker trips frequently, check for overloading or faulty wiring.
  • Overheating: Ensure proper ventilation and check for any obstructions around the breaker.
  • Mechanical Failure: Replace any worn-out parts immediately to maintain optimal performance.

7. Comparison with Other Circuit Breakers

7.1 Schneider GV4LE03N vs. Other Models

Compared to other models, the GV4LE03N offers superior breaking capacity and more precise trip settings. Its compact design also provides an edge in installations where space is limited.

7.2 Benefits of Choosing Schneider

Choosing Schneider Electric ensures quality, reliability, and access to a wide range of support services. Their products are designed to meet global standards, providing peace of mind to users.

8. Customer Reviews and Testimonials

8.1 Positive Feedback

Many users praise the GV4LE03N for its durability and ease of installation. Its high performance in various environments makes it a highly recommended product.

8.2 Areas for Improvement

Some users have noted that the cost can be higher compared to other brands. However, the overall quality and reliability justify the investment.

9. Conclusion

The Schneider GV4LE03N is a versatile and reliable circuit breaker suitable for industrial, commercial, and residential applications. Its advanced features, high breaking capacity, and ease of installation make it a top choice for protecting electrical systems. Investing in a Schneider GV4LE03N ensures safety, efficiency, and long-term reliability.

Additional information

brands

Schneider Electric

Specifications

Main
Range of product TeSys GV4
Range TeSys Deca TeSys Deca
Device short name GV4L
Product name TeSys GV4 TeSys Deca
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic Electronic
Complementary
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 0.55 kW at 400...415 V AC 50/60 Hz 0.75 kW at 400...415 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.1 kW at 660...690 V AC 50/60 Hz 1.5 kW at 660...690 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 660...690 V AC 50/60 Hz 1.1 kW at 400...415 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 3.5 A
Magnetic tripping current 21…49 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Tightening torque 9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
height 155 mm
Width 81 mm
Depth 116 mm
Net weight 1.5 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
Environment
Standards EN/IEC 60947-4-1 EN/IEC 60947-2
product certifications IEC CCC EAC EU-RO MR
Climatic withstand Conforming to IACS E10
IK degree of protection IK07 conforming to IEC 62262
Pollution degree 3
IP degree of protection IP40 conforming to IEC 60529
Ambient air temperature for storage -50…85 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Operating altitude 5000 m
Ambient air temperature for operation -25…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21.0 cm
Package 1 Width 11.0 cm
Package 1 Length 22.0 cm
Package 1 Weight 1.73 kg
Unit Type of Package 2 S03
Number of Units in Package 2 5
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 8.65 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : GV4LE03N

Main Document

Data Sheet : GV4LE03N

Reviews (0)

Be the first to review “Schneider GV4LE03N | Motor circuit breaker, TeSys GV4, 3P, 3.5 A, Icu 50 kA, magnetic, EverLink terminals”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare