Schneider GV4LE03N | Motor circuit breaker, TeSys GV4, 3P, 3.5 A, Icu 50 kA, magnetic, EverLink terminals
Description
Schneider GV4LE03N | Motor circuit breaker, TeSys GV4, 3P, 3.5 A, Icu 50 kA, magnetic, EverLink terminals
TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)
Schneider GV4LE03N?
The Schneider GV4LE03N is a robust circuit breaker designed to provide comprehensive protection in various electrical systems. Known for its reliability and efficiency, this model is a part of Schneider Electric’s extensive range of circuit protection devices.
1.2 Importance of Circuit Breakers
Circuit breakers are critical components in electrical systems. They prevent damage caused by overcurrent, short circuits, and electrical faults, ensuring the safety of both the equipment and the users.
2. Overview of Schneider Electric
2.1 Company History
Schneider Electric has a rich history dating back to the 19th century. Founded in 1836, the company has grown into a global leader in energy management and automation, offering innovative solutions across various industries.
2.2 Innovation in Electrical Solutions
Schneider Electric is renowned for its commitment to innovation. The company continuously develops cutting-edge products that enhance efficiency, safety, and sustainability in electrical management.
3. Detailed Description of Schneider GV4LE03N
3.1 Technical Specifications
The Schneider GV4LE03N features a compact design with a rated current of 0.25-32 A and a breaking capacity of up to 70 kA at 415 V AC. It is designed to operate within a temperature range of -25 to 70°C, making it suitable for diverse environments.
3.2 Key Features
- Adjustable Thermal-Magnetic Trip Unit: This feature allows for precise adjustment of the trip settings, ensuring optimal protection.
- Compact Design: The compact size makes it easy to integrate into various electrical systems.
- High Breaking Capacity: With a high breaking capacity, it can handle significant electrical faults without compromising performance.
- Wide Range of Accessories: Various accessories are available to enhance functionality and ease of installation.
3.3 Advantages
The GV4LE03N offers several advantages, including enhanced protection, easy installation, and minimal maintenance requirements. Its reliability and robust performance make it a preferred choice for many applications.
4. Applications of Schneider GV4LE03N
4.1 Industrial Use
In industrial settings, the GV4LE03N is used to protect machinery and equipment from electrical faults, ensuring continuous operation and safety.
4.2 Commercial Use
Commercial buildings benefit from the GV4LE03N’s ability to manage and protect electrical systems, reducing the risk of outages and equipment damage.
4.3 Residential Use
While primarily designed for industrial and commercial use, the GV4LE03N can also be used in residential settings where high performance and reliability are required.
5. Installation and Setup
5.1 Pre-Installation Requirements
Before installing the GV4LE03N, ensure that you have all the necessary tools and accessories. Check the electrical system’s specifications to match the breaker’s requirements.
5.2 Step-by-Step Installation Guide
- Turn Off Power: Ensure the power supply is completely shut off to avoid any electrical hazards.
- Mount the Breaker: Securely mount the GV4LE03N in the designated panel or enclosure.
- Connect Wires: Carefully connect the input and output wires according to the wiring diagram.
- Adjust Settings: Set the thermal-magnetic trip unit as per the system requirements.
- Power On: Restore power and test the breaker to ensure it functions correctly.
5.3 Safety Precautions
Always follow safety guidelines when installing electrical equipment. Wear appropriate protective gear and ensure the area is dry and free of conductive materials.
6. Maintenance and Troubleshooting
6.1 Regular Maintenance Tips
- Inspect Regularly: Perform routine inspections to check for any signs of wear or damage.
- Clean Components: Keep the breaker and its components clean from dust and debris.
- Test Functionality: Regularly test the breaker to ensure it operates correctly under load conditions.
6.2 Common Issues and Solutions
- Nuisance Tripping: If the breaker trips frequently, check for overloading or faulty wiring.
- Overheating: Ensure proper ventilation and check for any obstructions around the breaker.
- Mechanical Failure: Replace any worn-out parts immediately to maintain optimal performance.
7. Comparison with Other Circuit Breakers
7.1 Schneider GV4LE03N vs. Other Models
Compared to other models, the GV4LE03N offers superior breaking capacity and more precise trip settings. Its compact design also provides an edge in installations where space is limited.
7.2 Benefits of Choosing Schneider
Choosing Schneider Electric ensures quality, reliability, and access to a wide range of support services. Their products are designed to meet global standards, providing peace of mind to users.
8. Customer Reviews and Testimonials
8.1 Positive Feedback
Many users praise the GV4LE03N for its durability and ease of installation. Its high performance in various environments makes it a highly recommended product.
8.2 Areas for Improvement
Some users have noted that the cost can be higher compared to other brands. However, the overall quality and reliability justify the investment.
9. Conclusion
The Schneider GV4LE03N is a versatile and reliable circuit breaker suitable for industrial, commercial, and residential applications. Its advanced features, high breaking capacity, and ease of installation make it a top choice for protecting electrical systems. Investing in a Schneider GV4LE03N ensures safety, efficiency, and long-term reliability.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | TeSys GV4 |
|---|---|
| Range | TeSys Deca TeSys Deca |
| Device short name | GV4L |
| Product name | TeSys GV4 TeSys Deca |
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Magnetic Electronic |
| Poles description | 3P |
|---|---|
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Operating position | Any position |
| Motor power kW | 0.55 kW at 400...415 V AC 50/60 Hz 0.75 kW at 400...415 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz 1.1 kW at 660...690 V AC 50/60 Hz 1.5 kW at 660...690 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 660...690 V AC 50/60 Hz 1.1 kW at 400...415 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| control type | Toggle |
| [In] rated current | 3.5 A |
| Magnetic tripping current | 21…49 A |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ith] conventional free air thermal current | 115 A conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Power dissipation per pole | 6.1 W |
| Mechanical durability | 40000 cycles |
| Electrical durability | 40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In |
| Maximum operating rate | 25 cyc/h |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Connections - terminals | EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible |
| Tightening torque | 9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm² |
| Mechanical robustness | Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
| height | 155 mm |
| Width | 81 mm |
| Depth | 116 mm |
| Net weight | 1.5 kg |
| Colour | Grey (RAL 7016) |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-2 |
|---|---|
| product certifications | IEC CCC EAC EU-RO MR |
| Climatic withstand | Conforming to IACS E10 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Pollution degree | 3 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Ambient air temperature for storage | -50…85 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Operating altitude | 5000 m |
| Ambient air temperature for operation | -25…70 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 21.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 22.0 cm |
| Package 1 Weight | 1.73 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 8.65 kg |
| Warranty | 18 months |
|---|
Reviews
There are no reviews yet.