Schneider LADR4 | Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 10-180 s, front mounting, screw terminals
Schneider LADR4 | Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 10-180 s, front mounting, screw terminals
Description
Schneider LADR4 | Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 10-180 s, front mounting, screw terminals
1. Technical Specifications LADR4
-
Product Reference: LADR4
-
Range: TeSys D
-
Device Type: Time delay auxiliary contact block
-
Mounting Position: Front mounting on TeSys D contactors
-
Contact Configuration: 2 contacts total
-
1 Normally Open (NO)
-
1 Normally Closed (NC)
-
-
Time Delay Function: Off-delay (contacts remain engaged for a set period after coil de-energization)
-
Adjustable Time Range: 10 to 180 seconds
-
Control Voltage Source: Supplied through the contactor coil control circuit
-
Rated Operational Voltage (Ue): Up to 690 V AC
-
Insulation Voltage (Ui): 690 V
-
Dielectric Strength: 6 kV
-
Utilization Category: AC-15 and DC-13
-
Maximum Switching Voltage: 250 V
-
Rated Impulse Withstand Voltage (Uimp): 6 kV
-
Mechanical Durability: Up to 5 million operations
-
Electrical Durability: Up to 100,000 operations at rated load
-
Connection Terminals: Screw terminals
-
Mounting Compatibility: For use with TeSys D contactors (such as LC1D09…LC1D150)
-
Ambient Operating Temperature: –20°C to +60°C
-
Protection Class: IP20 (front face)
-
Standards Compliance: IEC 60947-5-1, CE, UL, CSA
2. Key Features
-
Provides adjustable off-delay timing from 10 to 180 seconds, ideal for sequencing or delay operations
-
Simple front-mounting design allows direct installation on TeSys D contactors without tools
-
Compact size ensures minimal additional space in control panels
-
Offers mechanically linked contacts to prevent simultaneous closure of NO and NC contacts
-
Screw-type terminals ensure secure, reliable connections
-
Time adjustment is manual and precise, via dial on the front of the module
-
Fully compliant with industrial control and automation standards
-
Enables enhanced automation logic without needing a separate PLC or timer relay
-
High reliability, robust construction, and long service life
3. Applications
-
Used in motor control circuits to delay disconnection of auxiliary devices after the main contactor opens
-
Suitable for industrial automation, packaging machines, conveyor systems, and control panels
-
Ideal for sequencing operations, e.g., allowing exhaust fans or safety interlocks to remain on after motor shutdown
-
Applied in HVAC systems, elevators, and lighting control where post-operation delay is needed
-
Commonly used for load shedding, cooling delay, or mechanical interlocks
-
Reduces the need for external time delay relays in many applications
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys TeSys Deca |
|---|---|
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys Deca CAD TeSys Deca LC1D TeSys F LC1F TeSys F CR1F |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | Off delay |
| Time delay range | 10...180 s |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ |
| Product certifications | IECEE CB Scheme UL CSA CCC EAC UKCA |
| Irms rated making capacity | 140 A at <= 690 V AC conforming to IEC 60947-5-1 250 A at <= 690 V DC conforming to IEC 60947-5-1 |
|---|---|
| Permissible short-time rating | 100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid Screw clamp terminals |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm 1.7 N.m - with screwdriver Philips No 2 1.7 N.m - with screwdriver pozidriv No 2 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Colour | Dark grey |
| Environmental characteristic | Normal environment |
|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…70 °C |
| Operating altitude | 3000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.200 cm |
| Package 1 Width | 6.500 cm |
| Package 1 Length | 5.000 cm |
| Package 1 Weight | 75.600 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.200 cm |
| Package 2 Width | 12.800 cm |
| Package 2 Length | 24.000 cm |
| Package 2 Weight | 756.000 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 140 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 11.129 kg |
| Warranty | 18 |
|---|
Reviews