it is a highly reliable and efficient contactor designed to meet the diverse needs of electrical applications. Whether you’re in the industrial sector or residential settings, this contactor offers superior performance and durability. In this article, we’ll delve into the various aspects of it, from its specifications to its applications, installation guide, and more.
Specifications
contactor is designed for AC-3 utilization category, making it suitable for controlling electrical circuits up to 690 volts. With a rated operational current of 60 amps, it can efficiently handle heavy loads, ensuring smooth operation without any interruptions. Additionally, it features a compact design, making it easy to integrate into existing electrical systems.
Applications of LC1DT60AM7
From motor control to HVAC systems and lighting applications, Schneider LC1DT60AM7 finds its use across various industries. Its versatility makes it an ideal choice for both commercial and industrial settings where reliable electrical control is essential. Whether it’s starting and stopping motors or controlling lighting circuits, this contactor delivers exceptional performance.
Benefits of Using
- Reliability: it is known for its reliability, ensuring uninterrupted operation even in harsh environments.
- Energy Efficiency: With its efficient design, it helps minimize energy consumption, leading to cost savings.
- Durability: Built to withstand heavy-duty use, this contactor offers long-term durability and performance.
- Ease of Installation: The compact design and user-friendly features of LC1DT60AM7 make installation quick and hassle-free.
Installation Guide
Installing it is straightforward, but it’s essential to follow the manufacturer’s guidelines to ensure proper operation. Begin by identifying the suitable location for the contactor, considering factors such as accessibility and ventilation. Next, carefully wire the contactor according to the provided wiring diagram, ensuring proper connections and cable sizing. Once installed, perform a thorough inspection to verify correct wiring and secure any loose connections.
Maintenance Tips
To ensure optimal performance and longevity of it, regular maintenance is crucial. Inspect the contactor periodically for signs of wear or damage, such as overheating or corrosion. Clean the contactor and surrounding area to remove any dust or debris that may affect performance. Additionally, conduct routine tests to verify proper operation and address any issues promptly.
Troubleshooting Common Issues
Despite its reliability, it may encounter occasional issues that require troubleshooting. Common problems include faulty connections, overheating, and coil failures. Refer to the user manual for troubleshooting steps and consult with a qualified technician if necessary.
Comparison with Similar Products
When choosing a contactor for your electrical needs, it’s essential to compare Schneider LC1DT60AM7 with similar products on the market. Consider factors such as price, specifications, and customer reviews to make an informed decision.
Customer Reviews and Feedback
Feedback from customers who have used Schneider LC1DT60AM7 can provide valuable insights into its performance and reliability. Check online reviews and testimonials to gauge user satisfaction and determine if it meets your requirements.
Warranty Information
Schneider LC1DT60AM7 comes with a standard warranty that covers manufacturing defects and malfunctions. Be sure to register your product to activate the warranty and contact Schneider Electric for any warranty-related inquiries or claims.
Where to Buy
Schneider LC1DT60AM7 is available through authorized distributors and retailers worldwide. Check the Schneider Electric website or contact their customer service for assistance in locating a reputable seller in your area.
Price Range
The price of Schneider LC1DT60AM7 may vary depending on factors such as quantity, location, and seller. Compare prices from different sources to find the best deal while ensuring product authenticity and reliability.
Conclusion
In conclusion, Schneider LC1DT60AM7 stands out as a top-tier contactor offering unparalleled performance, reliability, and versatility. Whether you’re a professional electrician or a DIY enthusiast, this contactor is sure to meet your electrical control needs with ease. Invest in Schneider LC1DT60AM7 for peace of mind and efficient operation of your electrical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys TeSys Deca |
|---|---|
| Range of product | TeSys Deca |
| product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load |
| Utilisation category | AC-1 |
| Poles description | 4P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Compatibility code | LC1D |
|---|---|
| Pole contact composition | 4 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 320 A 40 °C - 10 s for power circuit 720 A 40 °C - 1 s for power circuit 72 A 40 °C - 10 min for power circuit 165 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 1.6 mOhm - Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole | 5.8 W AC-1 |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 6 Mcycles |
| Electrical durability | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C) 160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 4…5 W at 50/60 Hz |
| Operating time | 4...19 ms opening 12...26 ms closing |
| Maximum operating rate | 3600 cyc/h 60 °C |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid without cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2 Power circuit: 2.5 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail Plate |
| Standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
|---|---|
| Product certifications | LROS (Lloyds register of shipping) UL GOST BV CCC CSA RINA DNV GL |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms) |
| Height | 122 mm |
| Width | 70 mm |
| Depth | 120 mm |
| Net weight | 1.09 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8 cm |
| Package 1 Width | 14 cm |
| Package 1 Length | 15 cm |
| Package 1 Weight | 1.097 kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 8.041 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 112 |
| Package 3 Height | 77 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 60 cm |
| Package 3 Weight | 138.644 kg |
| Warranty | 18 months |
|---|
Main documents
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1DT60AM7 |
|
Instruction sheet
|
Download |
|
Catalogue
|
Download |
|
CAD Files
|
Download |
| Environmental disclosure | Download |
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1DT60AM7 |
|
Instruction sheet
|
Download |
|
Catalogue
|
Download |
|
CAD Files |
Download |
| Environmental disclosure | Download |
Reviews (0)
Recommended for you
-
0
Schneider LC1D50AQ7 Contactor | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 50 A – 380 V AC 50/60 Hz coil
-
0
Schneider LC1D80F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 110 V AC 50/60 Hz coil
-
0
Schneider LC1D95B7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 24 V AC 50/60 Hz coil
-
0
Schneider LC1D95M7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 220 V AC 50/60 Hz coil
-
0
Reviews