In the world of electrical components, choosing the right parts is crucial for ensuring safety and efficiency. Schneider Electric, a leader in energy management and automation, provides a range of products designed to meet high standards of performance. One such product is the Schneider LRD313. This article will cover all essential aspects of the Schneider LRD313, from its features to its applications and benefits.

Understanding the Basics

What is Schneider LRD313?

it is a thermal overload relay designed to protect electrical circuits from overheating due to prolonged overcurrent conditions. It is a key component in ensuring the safety and efficiency of electrical systems, particularly in industrial and commercial applications.

Key Features and Specifications

it offers several notable features:

  • Adjustable Current Range: Provides flexibility in setting protection levels for different applications.
  • Compact Design: Allows for easy installation in confined spaces.
  • Thermal Protection: Effectively responds to overheating to prevent damage.
  • Compatibility: Designed to work seamlessly with Schneider’s range of contactors and other components.

Design and Build

Physical Design

it features a robust yet compact design. Its sleek appearance allows it to fit easily into standard control panels, making it ideal for a variety of installations.

Materials Used in Construction

Constructed from high-quality, durable materials, the Schneider LRD313 is built to withstand harsh conditions. The use of robust plastics and metals ensures long-term reliability and performance.

Durability and Lifespan

The LRD313 is designed to offer long-term durability, even under demanding conditions. Its solid construction contributes to its extended lifespan, making it a reliable choice for many applications.

Technical Specifications

Voltage and Current Ratings

The Schneider LRD313 is rated for a maximum voltage of 690V and can handle currents ranging from 4A to 32A. This range makes it versatile for various electrical systems.

Temperature Ratings

The relay operates efficiently within a temperature range of -20°C to +60°C, ensuring consistent performance in diverse environmental conditions.

Dimensions and Weight

With a compact footprint, the Schneider LRD313 measures approximately 77mm in height, 45mm in width, and 77mm in depth. It weighs about 250 grams, making it easy to handle and install.

Installation Process

Pre-installation Requirements

Before installing the Schneider LRD313, ensure that the power supply is turned off to prevent electrical shock. Gather the necessary tools and verify that the relay is appropriate for your specific application.

Step-by-Step Installation Guide

  1. Turn Off the Main Power: Always ensure that the power supply is disconnected before beginning installation.
  2. Prepare the Control Panel: Remove the cover of the control panel to access the mounting area.
  3. Install the Relay: Mount the Schneider LRD313 in the designated slot or panel.
  4. Wire the Relay: Connect the relay to the electrical circuit according to the wiring diagram provided.
  5. Adjust Settings: Set the current adjustment knob to the required protection level.
  6. Replace the Panel Cover: Once installation is complete, secure the panel cover.
  7. Restore Power: Turn the power back on and test the relay to ensure proper operation.

Safety Precautions

Always adhere to safety protocols when working with electrical components. Use insulated tools and wear protective gear to avoid injury.

Performance and Efficiency

Efficiency Ratings

The Schneider LRD313 is designed for optimal efficiency, minimizing energy loss and ensuring effective protection of electrical circuits.

Performance Under Different Conditions

This relay performs reliably under various environmental conditions, from commercial office spaces to industrial facilities. Its robust design ensures consistent performance.

Additional information

brands

Schneider Electric

Specifications

Main
Range TeSys TeSys Deca
Product name TeSys LRD TeSys Deca
product or component type Differential thermal overload relay
Device short name LRD
relay application Motor protection
Product compatibility LC1D40A LC1D50A LC1D65A
Network type AC DC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 9…13 A
[Ui] rated insulation voltage Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1
Complementary
Network frequency 0...400 Hz
Mounting support Plate, with specific accessories Rail, with specific accessories Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 0.95 A at 380 V AC-15 for signalling circuit 0.06 A at 440 V DC-13 for signalling circuit
[Ue] rated operational voltage 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit 4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button: stop Blue push-button: reset
Temperature compensation -20…60 °C
Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm² flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm² flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm² solid without cable end
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals Power circuit: 5 N.m - on EverLink BTR screw connectors
Height 70 mm
Width 55 mm
Depth 123 mm
net weight 0.375 kg
Environment
Climatic withstand Conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 4 gn conforming to IEC 60068-2-6
Dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 EN 50495
Product certifications IEC UL CSA CCC EAC DNV-GL RMRS EU-RO MR LROS (Lloyds register of shipping) ATEX INERIS UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.1 cm
Package 1 Width 10.5 cm
Package 1 Length 13.6 cm
Package 1 Weight 400 g
Unit Type of Package 2 S02
Number of Units in Package 2 13
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 5.502 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider LRD313 | TeSys LRD thermal overload relays – 9…13 A – class 10A”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare