Schneider LV516647 | Easypact CVS – CVS160N circuit breaker – 4P/3d
Schneider LV516647 | Easypact CVS – CVS160N circuit breaker – 4P/3d
Description
Schneider LV516647 | Easypact CVS – CVS160N circuit breaker – 4P/3d
Specifications:
-
Type: Circuit Breaker
-
Model: Easypact CVS160N
-
Rated Current: 160 Amps
-
Poles: 4P (Four Poles)
-
Design: 3d (Three-Phase, with adjustable protection settings)
-
Rated Voltage: Suitable for low-voltage electrical systems
-
Protection: Provides overload, short-circuit, and earth fault protection
Features:
-
Four-Pole Design:
-
The 4P (four-pole) design is ideal for systems requiring protection across four conductors, such as three-phase with neutral circuits, ensuring balanced protection across all phases.
-
-
Thermal Magnetic Protection:
-
The circuit breaker incorporates both thermal protection (for overloads) and magnetic protection (for short circuits), offering comprehensive protection against electrical faults.
-
-
Adjustable Trip Settings:
-
The breaker offers adjustable protection settings, allowing for customized settings tailored to specific operational conditions. This ensures optimal protection for a wide range of applications.
-
-
Compact and Reliable:
-
The Easypact CVS160N offers compact dimensions while maintaining a high level of performance and reliability, suitable for tight installations.
-
-
High Durability:
-
Built to withstand harsh conditions, this circuit breaker is designed for long-lasting performance in both industrial and commercial settings.
-
-
Easy Installation and Maintenance:
-
Its design allows for quick installation and easy maintenance, making it a practical choice for a wide range of applications.
-
-
Versatile Application:
-
The Easypact CVS160N is versatile and can be used in various environments, from residential to industrial and commercial applications.
-
Applications:
-
Industrial Power Systems: Ideal for protecting industrial machinery, control systems, and electrical panels in factories and manufacturing plants.
-
Commercial Buildings: Provides reliable protection for electrical distribution systems in office buildings, retail spaces, and commercial facilities.
-
Residential Power Distribution: Suitable for protecting the electrical systems in large residential buildings or housing complexes.
-
Motor Protection: Can be used in motor circuits to prevent damage from overloads or short circuits.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS100...250 |
| Product name | EasyPact CVS |
| Device short name | CVS160N |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 125 A at 40 °C |
| Network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 125 A at 40 °C |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| Network frequency | 50/60 Hz |
| Breaking capacity code | N |
| [Ics] rated service breaking capacity | 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Neutral position | Left |
| Mechanical durability | 25000 cycles |
| Electrical durability | 12000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Thermal protection adjustment range | 0…125 A |
| Neutral protection setting | No protection (3D) |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Short-time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| instantaneous pick-up adjustment range | 1250 A |
| Contact position indicator | Yes |
| Mounting support | Backplate |
| Mounting mode | Fixed |
| Upside connection | Front |
| downside connection | Front |
| Connections - terminals | Screw connection |
| Connection pitch | 35 mm |
| Compatibility code | CVS160 |
| Width | 140 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Net weight | 1.9 kg |
| Standards | EN 60947-2 IEC 60947-2 |
|---|---|
| Product certifications | GOST IEC |
| Electrical shock protection class | Class II |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 19.5 cm |
| Package 1 Weight | 2.63 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 15.78 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61521 | miniature circuit breaker – C60H – 2 poles – 1 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18569 | Vigi C120 – earth leakage add-on block – 4P – 30 mA – class AC
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9K24163 | Miniature circuit-breaker, Acti9 iK60N, 1P, 63 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.