In the realm of electrical engineering and automation,it contactor coil stands out as a vital component, especially within the TeSys D range. This article delves into the intricacies of this contactor coil, shedding light on its features, benefits, specifications, and more.
Introduction it
Contactor coils are indispensable elements in electrical systems, acting as electromechanical switches that control the flow of electricity. it contactor coil, designed for use with 80 & 95 A contactors, plays a crucial role in ensuring efficient and safe operations.
Understanding TeSys D Contactor Coil
A contactor coil is essentially an electromagnetic coil that, when energized, generates a magnetic field to close or open the contactor’s contacts. This action facilitates the switching of electrical circuits, making it a fundamental component in various industrial and commercial applications.
Specifications it
The LX1D6M7 contactor coil boasts a voltage rating of 220 V AC 50/60 Hz, making it compatible with a wide range of electrical setups. This versatility makes it a preferred choice for applications requiring reliable performance under varying voltage conditions.
Features and Benefits
One of the standout features of the LX1D6M7 contactor coil is its robust construction, ensuring durability and longevity even in demanding environments. Its easy installation process and minimal maintenance requirements further enhance its appeal to engineers and technicians.
Comparison with other contactor coils
When compared to other contactor coils in the market, it excels in terms of performance, reliability, and compatibility. Its ability to seamlessly integrate with Schneider’s TeSys D range of products makes it a preferred choice for electrical contractors and system integrators.
How to select the right contactor coil
Choosing the right contactor coil involves considering factors such as voltage rating, current capacity, compatibility with existing systems, and environmental conditions. Consulting with experts and following manufacturer guidelines can aid in making informed decisions.
Installation and Maintenance
An in-depth installation guide for it contactor coil ensures a hassle-free setup process, while regular maintenance routines help in preserving its efficiency and longevity. Following recommended practices is crucial for optimal performance and safety.
Conclusion
In conclusion, it contactor coil represents a pinnacle of reliability and performance in the realm of electrical components. Its seamless integration, coupled with Schneider’s reputation for quality, makes it a go-to choice for diverse industrial and commercial applications.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys |
|---|---|
| Product or component type | Contactor coil |
| Device short name | LX1D6 |
| Control circuit type | AC at 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 50/60 Hz |
| Average resistance | 102 Ohm at 20 °C |
| Inductance of closed circuit | 6.7 H |
| Product compatibility | LC1D40 LC1D50 LC1D65...D95 |
| Mechanical durability | 4 Mcycles |
| Maximum operating rate | 3600 cyc/h 60 °C |
| Coil technology | Without built-in suppressor module |
|---|---|
| Control circuit voltage limits | Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C) Operational: 0.8...1.1 Uc at 50 Hz (at <55 °C) Operational: 0.85...1.1 Uc at 60 Hz (at <55 °C) |
| Inrush power in VA | 245 VA 60 Hz cos phi 0.75 (at 20 °C) 245 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 26 VA 60 Hz cos phi 0.3 (at 20 °C) 26 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 6…10 W at 50/60 Hz |
| Ambient air temperature for operation | -5…60 °C |
|---|---|
| Net weight | 0.28 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.700 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 12.500 cm |
| Package 1 Weight | 313.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.318 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider LC1D65AE7 | IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VAC 50/60Hz coil, open
Schneider LADR4 | Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 10-180 s, front mounting, screw terminals
Schneider LC1D40AB7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 40 A – 24 V AC 50/60 Hz coil
Schneider LC1D18F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 110 V AC coil
-
0
Reviews
There are no reviews yet.