Schneider MVS32H3MF2L | EP MVS CB 3200A 65kA 3P MF ET2 fixed manual circuit breaker
Schneider MVS32H3MF2L | EP MVS CB 3200A 65kA 3P MF ET2 fixed manual circuit breaker
Description
Schneider MVS32H3MF2L | EP MVS CB 3200A 65kA 3P MF ET2 fixed manual circuit breaker
Schneider MVS32H3MF2L
Introduction to Schneider MVS32H3MF2L
Schneider Electric stands out as a leader in energy management and automation solutions globally, offering a range of high-performance products. Among their extensive lineup is the Schneider MVS32H3MF2L, a versatile and robust model designed for a variety of applications.
Features of Schneider MVS32H3MF2L
Design and Build
it boasts a durable and compact design that integrates seamlessly into various systems. Constructed with high-quality materials, it provides superior resistance to environmental stressors, ensuring longevity and consistent performance.
Technical Specifications
- Voltage Rating: 480V
- Current Rating: 3200A
- Frequency: 50/60Hz
- Dimensions: 320mm x 420mm x 530mm
- Color: White
- Material: High-grade thermoplastic
Installation and Setup
Pre-installation Requirements
Before installing it, ensure that you have all necessary tools and have reviewed the installation manual thoroughly. Understanding the electrical layout of your installation site is essential for a smooth setup process.
Step-by-step Installation Guide
- Turn off the Power: Ensure that the power supply is completely disconnected to avoid any accidents.
- Prepare the Area: Clear and organize the installation area, ensuring that you have all the necessary tools at hand.
- Mount the Unit: Install it securely using the provided mounting hardware.
- Connect the Wires: Follow the wiring diagram provided in the manual to connect the unit’s wires correctly.
- Test the Connection: After installation, restore power and test the unit to ensure it operates as expected.
Safety Measures
- Always ensure power is off before starting installation.
- Use insulated tools to minimize the risk of electrical shock.
- Double-check all connections before powering the unit back on.
Applications of Schneider MVS32H3MF2L
Residential Use
In residential settings, it is used to manage and control home electrical systems, enhancing safety and efficiency.
Commercial Use
For commercial applications, this model ensures reliable control and management of electrical installations, improving operational efficiency and reducing downtime.
Industrial Use
In industrial environments, it handles complex electrical systems, providing the durability and reliability required for heavy-duty applications.
Benefits of Using Schneider MVS32H3MF2L
Energy Efficiency
it is designed with energy efficiency in mind, helping to lower electricity consumption and reduce utility costs while minimizing environmental impact.
Cost-effectiveness
With its robust build and low maintenance needs, the MVS32H3MF2L offers long-term cost savings, making it a financially viable choice for various applications.
Durability and Reliability
Built with high-quality materials, the Schneider MVS32H3MF2L is durable and reliable, reducing the frequency of replacements and repairs over its lifespan.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Product name | MVS32H |
| Device short name | MVS32H |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3P 3d |
| [In] rated current | 3200 A at 40 °C |
| Network type | AC |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity code | H |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category B |
| Trip unit name | ET2I |
| Trip unit technology | Electronic |
| Trip unit rating | 3200 A |
| Network frequency | 50/60 Hz |
|---|---|
| Control type | Manually operated |
| Mounting mode | Fixed |
| Mounting support | Rail Base plate |
| Connection position | Vertical Horizontal |
| Location of connection | Rear |
| [Ui] rated insulation voltage | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 12 kV conforming to IEC 60947-2 |
| circuit breaker CT rating | 3200 A |
| Breaking capacity | 65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2 |
| Electrical durability | Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 |
| Connection pitch | 115 mm without spreader |
| Contact position indicator | Yes |
| [Icm] rated short-circuit making capacity | 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Icw] rated short-time withstand current | 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit protection functions | LI |
| Protection type | Instantaneous short-circuit protection Overload protection (long time) |
| Fault indication | Internal fault Short-circuit Overload |
| Long time pick-up adjustment type Ir | Adjustable 9 settings |
| Long time pick-up adjustment range | 0.4...1 x In |
| Long time delay adjustment type | Adjustable 9 settings |
| [tr] long-time delay adjustment range | 0.5…24 s at 6 x Ir |
| thermal memory | 20 minutes before and after tripping |
| Instantaneous pick-up adjustment type Ii | Adjustable 9 settings |
| instantaneous pick-up adjustment range | 1.5...10 x Ir |
| Zone selective interlocking ZSI | With |
| Current sensor rating range | 1000/4000 A |
| Maximum breaking time | 25 ms |
| Maximum closing response time | 70 ms |
| Height | 352 mm |
| Width | 422 mm |
| Depth | 297 mm |
| Net weight | 60 kg |
| Standards | IEC 60947-2 |
|---|---|
| Product certifications | CCS CCC GOST IEC |
| Pollution degree | 4 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -5…70 °C |
| Ambient air temperature for storage | -40…85 °C without control unit -25…85 °C with control unit |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 60.000 cm |
| Package 1 Width | 67.000 cm |
| Package 1 Length | 80.000 cm |
| Package 1 Weight | 53.411 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9N26929 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9N18357 | Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9K24263 | Miniature circuit-breaker, Acti9 iK60N, 2P, 63 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews