Schneider TM200C60R | Controller M200 60I/O relay
Schneider TM200C60R | Controller M200 60I/O relay
Description
Schneider TM200C60R | Controller M200 60I/O relay
Schneider TM200C60R Description
Introduction
Schneider Electric is a global leader in energy management and automation solutions. Their products are designed to enhance efficiency and sustainability across various industries. One such product is the TM200C60R, a versatile and robust module that offers extensive capabilities for automation systems. In this article, we will provide a comprehensive overview of the Schneider TM200C60R, exploring its features, applications, and benefits.
What is the Schneider TM200C60R?
The Schneider TM200C60R is a powerful logic controller module designed to optimize and streamline automation processes. It is part of Schneider’s Modicon M200 series, known for its flexibility, performance, and ease of use. This module is ideal for applications requiring reliable control and monitoring capabilities.
Key Features
- Integrated I/O: Equipped with 36 digital inputs and 24 relay outputs, allowing for extensive control and monitoring.
- Compact Design: The small footprint makes it easy to integrate into various control panels and systems.
- High Performance: Ensures fast and accurate processing of control tasks.
Technical Specifications
Understanding the technical specifications of the TM200C60R is crucial for ensuring it meets your system’s requirements.
Dimensions and Weight
- Height: 90 mm
- Width: 200 mm
- Depth: 60 mm
- Weight: 500 g
Power Requirements
- Voltage: 24 V DC
- Current Consumption: 350 mA
Connectivity Options
- Communication Ports: Ethernet, Serial (RS485)
- Input/Output Channels: 36 digital inputs, 24 relay outputs
Installation and Setup
Installing the TM200C60R is straightforward, but it’s essential to follow the guidelines to ensure optimal performance.
Pre-Installation Requirements
- Tools Needed: Screwdriver, Multimeter
- Environmental Conditions: Temperature range of -10°C to 50°C
Step-by-Step Installation Guide
- Power Down: Ensure the system is powered down before installation.
- Mounting: Secure the module using the provided screws.
- Wiring: Connect the input and output wires according to the wiring diagram.
- Power Up: Once connected, power up the system and verify proper operation.
Performance and Efficiency
The TM200C60R module is designed for high performance and efficiency, making it ideal for various automation needs.
Operational Capabilities
- Processing Speed: High-speed processing for real-time control applications.
- Load Capacity: Supports up to 2A per output channel
Energy Efficiency
- Low Power Consumption: Designed to minimize energy usage, contributing to overall system efficiency.
Applications of TM200C60R
The TM200C60R module is versatile, making it suitable for a variety of applications across different industries.
Industrial Uses
- Manufacturing: Enhances automation processes and improves production efficiency.
- Energy Management: Helps in monitoring and controlling energy usage.
Commercial Applications
- Building Automation: Integrates with building management systems for improved control.
- HVAC Systems: Used in heating, ventilation, and air conditioning systems for better performance.
Case Studies
- Case Study 1: A manufacturing plant improved its production line efficiency by 25% after integrating the TM200C60R.
- Case Study 2: A commercial building reduced its energy consumption by 20% using the TM200C60R in its HVAC system.
Advantages of Using TM200C60R
Investing in the TM200C60R module offers several benefits that can significantly enhance your system’s performance.
Enhanced Productivity
- Streamlined Operations: Simplifies processes and reduces manual intervention.
- Real-Time Monitoring: Provides immediate feedback, allowing for quick adjustments.
Cost-Effectiveness
- Reduced Downtime: Reliable operation minimizes system downtime.
- Lower Energy Bills: Energy-efficient design reduces operational costs.
Integration with Other Schneider Products
The TM200C60R is designed to seamlessly integrate with other Schneider Electric products, allowing for scalable and versatile automation solutions.
Compatibility
- Schneider PLCs: Easily integrates with Schneider programmable logic controllers.
- EcoStruxure™: Compatible with Schneider’s EcoStruxure™ platform for enhanced control and monitoring.
System Expansion
- Modular Design: Allows for easy addition of more modules as needed.
- Future-Proof: Designed to support future upgrades and expansions.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Easy Modicon M200 |
|---|---|
| Product or component type | Logic controller |
| [Us] rated supply voltage | 220 V AC |
| Discrete I/O number | 60 |
| Discrete input number | I2...I5: 4 fast input I0, I1, I6, I7: 4 high speed input I8...I35: 28 regular input |
| Discrete output number | 24 relay |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| Discrete input current | 7 mA for input |
| Discrete input logic | Sink or source (positive/negative) type 1 conforming to IEC 61131-2 |
| Discrete output voltage | 24 V DC 220 V AC |
| Discrete output current | 2 A |
| Discrete output type | Relay normally open |
| Power consumption in VA | 61…74 VA at 100...240 V AC (with max I/O) |
| Maximum number of I/O expansion module | 4 with 128 discrete output(s) for transistor output 4 with 88 discrete output(s) for relay output |
|---|---|
| Supply voltage limits | 85…264 V |
| Inrush current | 50 A |
| Voltage state 1 guaranteed | >= 15 V for input |
| Voltage state 0 guaranteed | <= 5 V for input |
| Input impedance | 3.3 kOhm for discrete input |
| Response time | 10 ms turn-on, Q0...Q23 terminal(s) for output 10 ms turn-off, Q0...Q23 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I35 terminal(s) for regular input 55 µs turn-on, I14...I35 terminal(s) for regular input |
| Configurable filtering time | 0 ms for input 3 ms for input 12 ms for input |
| Output voltage limits | 30 V DC 250 V AC |
| Maximum current per output common | 4 A at COM 2 4 A at COM 0 4 A at COM 1 4 A at COM 3 4 A at COM 4 4 A at COM 5 |
| Electrical durability | 100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive |
| Switching frequency | 0.1 Hz with maximum load |
| Mechanical durability | 20000000 cycles for relay output |
| Minimum load | 10 mA at 5 V DC for relay output |
| Memory capacity | 512 byte internal flash for backup of programs |
| Data storage equipment | 32 GB micro SD card (optional) |
| Battery type | BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) |
| Backup time | 3 years at 25 °C (by interruption of power supply) |
| Execution time for 1 KInstruction | 0.3 ms for event and periodic task |
| Execution time per instruction | 0.2 µs Boolean |
| Exct time for event task | 60 µs response time |
| Clock drift | <= 90 s/month at 25 °C |
| Regulation loop | Adjustable PID regulator up to 14 simultaneous loops |
| Control signal type | Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode) |
| Counting input number | 4 fast input (HSC mode) at 100 kHz 32 bits |
| Integrated connection type | USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface Isolated serial link serial 2 with terminal block connector and RS485 interface |
| Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB |
| Communication port protocol | USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network |
| Local signalling | 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED per channel (green) for I/O state |
| Electrical connection | Mini B USB 2.0 connectorfor a programming terminal removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply |
| Maximum cable distance between devices | Unshielded cable: <50 m for input Shielded cable: <10 m for fast input Shielded cable: <10 m for high speed input Unshielded cable: <150 m for output |
| Insulation | Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Between input groups at 500 V AC |
| Sensor power supply | 24 V DC at 300 mA supplied by the controller |
| Marking | CE |
| Mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 |
| Height | 90 mm |
| Depth | 70 mm |
| Width | 225 mm |
| Net weight | 0.684 kg 0.684 kg |
| IP degree of protection | IP20 with protective cover in place |
|---|---|
| Standards | IEC 61131-2 IEC 61010-2-201 |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m conforming to IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011 Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 |
| Shock resistance | 15 gn for 11 ms 30 gn for 6 ms |
| Immunity to microbreaks | 10 ms |
| Vibration resistance | 3.5 mm at 5…8.4 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.7 Hz on panel mounting 2 gn at 8.7…150 Hz on panel mounting |
| Relative humidity | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
| Ambient air temperature for operation | 0…55 °C (horizontal installation) |
| Ambient air temperature for storage | -25…70 °C |
| Pollution degree | <= 2 |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.467 cm |
| Package 1 Width | 13.692 cm |
| Package 1 Length | 23.764 cm |
| Package 1 Weight | 900.5 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 8629.5 g |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 216 |
| Package 3 Height | 95 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 216108 g |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider NSYEC86 | Plain cable gland plate, PanelSeT SFN, PanelSeT SF, for electrical enclosure W800 D600mm, fixed by clips
Schneider NSYSFD206 | Spacial SF plain door – 2000×600 mm
Schneider NSYSFC66 | Spacial SF bottom and top frame – 600×600 mm
-
0
Schneider NSYSM2012602D | PanelSeT SM compact enclosure without mounting plate – 2000x1200x600 mm
-
0
Schneider LE1D25Q7 | Enclosed DOL starter,TeSys LE,25A,380V AC coil,including 1 LC1D,2 pushbuttons
-
0
Reviews
There are no reviews yet.