Description
Schneider LAEN22 | Auxiliary contact block, EasyPact TVS, 2NO+2NC
Schneider LAEN22 | Auxiliary Contact Block, EasyPact TVS, 2NO+2NC Description
In the realm of electrical components, the Schneider LAEN22 auxiliary contact block stands out as a crucial element. Paired with the advanced features of EasyPact TVS and its 2NO+2NC configuration, this combination offers a robust solution for various electrical applications.
Introduction to Schneider LAEN22
it is a high-quality auxiliary contact block designed to complement EasyPact TVS circuit breakers. It enhances the functionality of electrical installations by providing additional contact points for control circuits.
Overview of Auxiliary Contact Blocks
Auxiliary contact blocks like the LAEN22 are essential in electrical systems to signal the status of a circuit or to control additional functions. They act as extensions to primary contacts, offering versatility and expanded capabilities.
Understanding EasyPact TVS
EasyPact TVS is a range of reliable and efficient circuit breakers from Schneider Electric. Known for their performance and durability, EasyPact TVS breakers are widely used in industrial and commercial settings.
Description of 2NO+2NC Configuration
The 2NO+2NC configuration of EasyPact TVS refers to two normally open (NO) and two normally closed (NC) contacts. This configuration provides flexibility in electrical connections, allowing for diverse control options.
Benefits of Schneider LAEN22
- Enhanced control: it enables precise control over electrical circuits.
- Compatibility: Designed specifically for EasyPact TVS, ensuring seamless integration.
- Versatility: Supports various applications due to its 2NO+2NC configuration.
- Reliability: Schneider Electric’s reputation for quality ensures long-term reliability.
Installation Guide for Auxiliary Contact Blocks
Installing it auxiliary contact block is straightforward, requiring alignment with compatible EasyPact TVS breakers and secure mounting following manufacturer guidelines.
Maintenance Tips for EasyPact TVS
Regular inspection and maintenance of EasyPact TVS breakers and it contact blocks are crucial for optimal performance and safety. Follow recommended schedules and procedures provided by Schneider Electric.
Applications of 2NO+2NC Configuration
The 2NO+2NC configuration is beneficial in various scenarios such as motor control, lighting systems, and safety circuits. Its dual functionality allows for both control and monitoring tasks within electrical installations.
Importance of Electrical Safety
In any electrical system, safety is paramount. Utilizing high-quality components like Schneider LAEN22 and EasyPact TVS not only ensures operational efficiency but also reduces the risk of electrical hazards.
Conclusion
Schneider LAEN22, coupled with EasyPact TVS and its 2NO+2NC configuration, offers a reliable and efficient solution for modern electrical installations. Its versatility, compatibility, and safety features make it a preferred choice in industrial and commercial sectors.
FAQs on Schneider LAEN22
- What is the maximum current rating of it?
- Can it be used with other brands of circuit breakers?
- Are there any specific environmental conditions to consider during installation?
- How often should EasyPact TVS breakers and it contact blocks be inspected?
- Is there a warranty period for it and EasyPact TVS products?
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Easy TeSys |
|---|---|
| range of product | Easy TeSys Control |
| product or component type | Auxiliary contact block |
| device application | Signalling |
| Device short name | LAEN |
| Colour | Grey (RAL 7011) |
| Range compatibility | EasyPact EasyPact TVS LC1E |
|---|---|
| Mounting location | Front |
| Auxiliary contacts operation | Instantaneous |
| Pole contact composition | 2 NO + 2 NC |
| [Ui] rated insulation voltage | 690 V - for control circuit conforming to IEC 60947-5-1 |
| [Ue] rated operational voltage | <= 690 V |
| [Ith] conventional free air thermal current | 8 A (at 60 °C) |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 100 A - 1 s 120 A - 500 ms 140 A - 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 10 Mcycles |
| Minimum switching current | 5 mA |
| minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on energisation no overlap between NC and NO contact 1.5 ms on de-energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Control circuit: screw clamp terminals 1 1 mm² - external diameter: 6 mm - cable stiffness: solid or flexible with cable end Control circuit: screw clamp terminals 1 1 mm² - external diameter: 6 mm - cable stiffness: solid or flexible without cable end Control circuit: screw clamp terminals 2 2.5 mm² - external diameter: 6 mm - cable stiffness: solid or flexible with cable end Control circuit: screw clamp terminals 2 2.5 mm² - external diameter: 6 mm - cable stiffness: solid or flexible without cable end |
| net weight | 0.06 kg |
| Environmental characteristic | Standard environment |
|---|---|
| Standards | IEC 60947-5-1 |
| Product certifications | GOST |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -5…55 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 3000 m without derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.800 cm |
| Package 1 Width | 4.500 cm |
| Package 1 Length | 5.000 cm |
| Package 1 Weight | 61.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 72 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.729 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider LC1E3210M7 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,32A,220V AC coil,50/60Hz,1NO auxiliary contact
-
0
Schneider LC1E0901M7 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,9A,220V AC coil,50/60Hz,1NC auxiliary contact
-
0
Reviews
There are no reviews yet.