Schneider ATS480D38Y | Soft starter, Altistart 480, 38A, 208 to 690V AC, control supply 110 to 230V AC
Description
Schneider ATS480D38Y| Soft starter, Altistart 480, 38A, 208 to 690V AC, control supply 110 to 230V AC
Schneider ATS480D38Y | Soft Starter Overview
The Schneider ATS480D38Y is a soft starter from the Altistart 480 series, designed to provide controlled motor acceleration and deceleration. It helps reduce mechanical stress, optimize energy efficiency, and enhance the lifespan of motors in industrial applications.
1. General Specifications
-
Product Name: Schneider ATS480D38Y
-
Series: Altistart 480
-
Function: Soft Starter
-
Rated Current: 38A
-
Operating Voltage: 208V to 690V AC
-
Control Supply Voltage: 110V to 230V AC
2. Key Features & Benefits
Smooth Motor Start & Stop: Minimizes mechanical wear and tear.
Wide Voltage Range: Supports 208V to 690V AC for flexible applications.
Energy Efficiency: Reduces power surges and improves overall system efficiency.
Built-in Motor Protection: Guards against overloads, short circuits, and overheating.
User-Friendly Interface: Digital display for easy monitoring and configuration.
Seamless Integration: Compatible with industrial automation networks.
3. Applications
🔹 Pumps & Compressors – Prevents sudden pressure surges and enhances system durability.
🔹 Fans & Blowers – Ensures smooth acceleration for HVAC systems.
🔹 Conveyors & Material Handling – Provides controlled motor startup and reduces mechanical stress.
🔹 Industrial Machinery – Ideal for crushers, mixers, and processing equipment.
🔹 Water & Wastewater Treatment – Ensures stable and reliable motor operation.
4. Protection & Safety Features
-
Overload Protection – Prevents excessive current draw and overheating.
-
Short Circuit Protection – Enhances system reliability and safety.
-
Overtemperature Protection – Protects against excessive heat buildup.
-
Phase Loss & Imbalance Detection – Ensures stable motor performance and longevity.
5. Installation & Maintenance
Easy Setup & Wiring – Simplifies installation in electrical panels.
Advanced Diagnostics & Monitoring – Enables real-time fault detection.
Low Maintenance Design – Reduces downtime and operational costs.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of Product | Altivar Soft Starter ATS480 |
|---|---|
| Product or Component Type | Soft starter |
| Product destination | Asynchronous motors |
| Product Specific Application | Process and infrastructures |
| Device short name | ATS480 |
| Phase | 3 phase |
| Utilisation category | AC-3A AC-53A |
| Ue power supply voltage | 208...690 V - 15...10 % |
| power supply frequency | 50...60 Hz - 20...20 % |
| [Ie] rated operational current | Normal duty 38.0 A 104 °F (40 °C)) |
| rated current in heavy duty | 32.0 A at 104 °F (40 °C) heavy duty |
| Torque control | True |
| IP Degree of Protection | IP20 |
| Motor power kW | 9.0 kW 230 V in the motor supply line normal duty 7.5 kW 230 V in the motor supply line heavy duty 18.5 kW 400 V in the motor supply line normal duty 15.0 kW 400 V in the motor supply line heavy duty 18.5 kW 440 V in the motor supply line normal duty 15.0 kW 440 V in the motor supply line heavy duty 22.0 kW 500 V in the motor supply line normal duty 18.5 kW 500 V in the motor supply line heavy duty 22.0 kW 525 V in the motor supply line normal duty 18.5 kW 525 V in the motor supply line heavy duty 30.0 kW 660 V in the motor supply line normal duty 22.0 kW 660 V in the motor supply line heavy duty 30.0 kW 690 V in the motor supply line normal duty 22.0 kW 690 V in the motor supply line heavy duty 18.5 kW 230 V to the motor delta terminals normal duty 15.0 kW 230 V to the motor delta terminals heavy duty 30.0 kW 400 V to the motor delta terminals normal duty 22.0 kW 400 V to the motor delta terminals heavy duty |
| Maximum Horse Power Rating | 10.0 hp 208 V normal duty 7.5 hp 208 V heavy duty 10.0 hp 230 V heavy duty 25.0 hp 460 V normal duty 20.0 hp 460 V heavy duty 30.0 hp 575 V normal duty 25.0 hp 575 V heavy duty |
| Option card | Communication module Profibus DP V1 Communication module Modbus TCP/EtherNet/IP Communication module CANopen daisy chain Communication module CANopen Sub-D Communication module CANopen open style |
| Device connection | In the motor supply line To the motor delta terminals |
|---|---|
| [Us] control circuit voltage | 110...230 V AC 50/60 Hz - 15...10 % |
| Apparent power | 0.09 kVA |
| Integrated motor overload protection | True |
| motor thermal protection class | Class 10E |
| Protection type | Phase failure line Integrated thermal protection motor Thermal protection starter Current overload motor Underload motor Excessive starting time, locked rotor motor Motor phase loss motor Line supply phase loss line Line supply phase loss motor Thermal protection motor |
| current limiting %In (5 x Ie maximum) | 150…700 % |
| [In] Rated current pwr loss specifctn | 38.0 A |
| Power loss static current independent | 25.0 W |
| Power loss per device current dependent | 96.0 W |
| Standards | IEC 60947-4-2 UL 60947-4-2 IEC 60664-1 |
| Product Certifications | CE cULus CCC UKCA RCM EAC DNV ABS BV CCS |
| Marking | CE CCC UKCA EAC RCM CULus |
| [Uc] control circuit voltage | 24 V DC |
| Discrete input number | 4 |
| Discrete input type | STOP) logic inputs, 3500 Ohm RUN) logic inputs, 3500 Ohm DI3) programmable as logic input, 3500 Ohm DI4) programmable as logic input, 3500 Ohm |
| Input compatibility | STOP discrete input level 1 PLC IEC 61131-2 RUN discrete input level 1 PLC IEC 61131-2 DI3 discrete input level 1 PLC IEC 61131-2 DI4 discrete input level 1 PLC IEC 61131-2 |
| Discrete input logic | Programmable digital input < 5 V |
| Relay output number | 3 |
| Relay output type | Relay outputs R1A 1 NO Relay outputs R1B 1 NO Relay outputs RIC NO/NC programmable |
| Minimum switching current | 100 mA 12 V DC relay outputs |
| Maximum switching current | Relay outputs 2 A 250 V AC Relay outputs 2 A 30 V DC |
| Discrete output number | 2 |
| Discrete output type | DQ1) programmable digital output <= 30 V DQ2) programmable digital output <= 30 V |
| Output compatibility | Open collector level 1 PLC IEC 65A-68 |
| Analogue input number | 1 |
| Analogue input type | AI1/PTC PTC/Pt 100 temperature probe PTC2 PTC/Pt 100 temperature probe PTC3 PTC/Pt 100 temperature probe |
| Analogue output number | 1 |
| Analogue output type | Current output AQ1 0...20 mA or 0...10 V 500 Ohm |
| Communication Port Protocol | Modbus serial |
| Connector Type | 1 RJ45 |
| Communication data link | Serial |
| Physical interface | 2-wire RS 485 |
| Transmission Rate | 1200...256000 bit/s |
| Transmission frame | RTU |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance Modbus serial |
| Number of addresses | 0…227 Modbus serial |
| Method of access | Slave Modbus serial |
| Function Available | External bypass control Pre-heating Smoke extraction Multi-motor cascade Second motor set User management Ports and services hardening Security event logging Cybersecure firmware update Single direction |
| Display screen available | True |
| Operating position | Vertical +/- 10 degree |
| Height | 10.8 in (275.0 mm) |
| Width | 6.3 in (160.0 mm) |
| Depth | 8.0 in (203.0 mm) |
| Net Weight | 10.8 lb(US) (4.9 kg) |
| Electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-11 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
|---|---|
| pollution degree | Level 3 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| [Ui] Rated Insulation Voltage | 690 V |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
| Relative humidity | 0…95 % without condensation or dripping water IEC 60068-2-3 |
| Ambient air temperature for operation | 104…140 °F (40…60 °C) (with current derating of 2 % per °C) 5…104 °F (-15…40 °C) (without derating) |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Operating altitude | <= 3280.84 ft (1000 m) without derating > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Maximum deflection under vibratory load (during storage) | 1.75 mm at 2...9 Hz |
| Maximum deflection under vibratory load (during transport) | 1.75 mm at 2...9 Hz |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum acceleration under vibratory load (during storage) | 15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz |
| Maximum acceleration under vibratory load (during transport) | 15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under shock load (during storage) | 100 m/s² at 11 ms |
| Maximum acceleration under shock load (during transport) | 100 m/s² at 11 ms |
| Category | US1CP1G22588 |
|---|---|
| Discount Schedule | CP1G |
| GTIN | 3606481089021 |
| Returnability | Yes |
| Country of origin | ID |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.69 in (29.700 cm) |
| Package 1 Width | 10.55 in (26.800 cm) |
| Package 1 Length | 14.37 in (36.500 cm) |
| Package 1 Weight | 13.545 lb(US) (6.144 kg) |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 29.53 in (75.000 cm) |
| Package 2 Width | 23.62 in (60.000 cm) |
| Package 2 Length | 31.50 in (80.000 cm) |
| Package 2 Weight | 144.954 lb(US) (65.750 kg) |
Reviews