Schneider A9D11820 | iC60H – earth leakage circuit breaker – 1P + N – C curve – 20 A – 30 mA – 240 V
Specifications
-
Product Type: RCBO (Residual Current Circuit Breaker with Overcurrent protection)
-
Series: Acti9 iC60H
-
Model Number: A9D11820
-
Poles: 1P+N (1 protected pole + neutral switching)
-
Rated Current: 20 A
-
Residual Current Sensitivity: 30 mA
-
Tripping Curve: C Curve (suitable for general applications with moderate inrush current)
-
Rated Voltage: 240 V AC
-
Rated Frequency: 50/60 Hz
-
Breaking Capacity: 6 kA (IEC 61009-1)
-
RCD Type: Type AC (detects sinusoidal AC leakage currents)
-
Mounting: DIN rail
-
Terminal Type: Tunnel type terminals
-
IP Rating: IP20 (IP40 when installed in enclosure)
-
Operating Temperature: -25°C to +60°C
-
Standards Compliance: IEC 61009-1, IEC 61009-2-1
-
Approvals: CE, KEMA, etc.
Features
-
Dual Protection: Combines earth leakage and overcurrent protection in one unit.
-
Compact Size: Saves space in the distribution board.
-
High Sensitivity: 30 mA RCD sensitivity for personal protection against electric shock.
-
Visual Indicator: Clear status indication for quick diagnostics.
-
Safe Installation: Finger-safe terminals and robust mechanical build.
-
Fast Tripping: Ensures quick disconnection in case of faults.
Applications
-
Residential circuits – lighting, sockets, small appliances
-
Bathrooms and kitchens – high-risk areas needing extra protection
-
Commercial units – office equipment and lighting
-
General purpose outlets – where combined RCD and MCB protection is preferred
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Circuit breaker application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 RCBO |
| product or component type | Residual current breaker with overcurrent protection (RCBO) |
| Device short name | iC60H RCBO |
| Poles description | 1P + Ns |
| [In] rated current | 20 A at 50 °C |
| Earthing system | TN |
| Curve code | C |
| Earth-leakage sensitivity | 30 mA |
| Breaking capacity | 10000 A Icn at 230/240 V AC 50/60 Hz |
| Neutral position | Left |
|---|---|
| Number of protected poles | 1 |
| Device location in system | Outgoer |
| Network frequency | 50 Hz |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| [Ue] rated operational voltage | 230/240 V AC 50/60 Hz |
| Residual current tripping technology | Voltage dependent |
| Earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type A |
| [Icw] rated short-time withstand current | Icw: 250 A during 8/20 µs impulse withstand |
| [Ics] rated service breaking capacity | 7500 A at 230/240 V AC 50/60 Hz |
| Limitation class | 3 |
| [Ui] rated insulation voltage | 400 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Surge current | 250 A |
| Suitability for isolation | Yes |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | NO |
| 9 mm pitches | 2 |
| Height | 110 mm |
| Width | 18 mm |
| Depth | 77.5 mm |
| net weight | 205 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 5000 cycles |
| Provision for padlocking | Padlockable with padlock Ø 4 mm |
| Locking options description | ON/OFF locking facilities |
| Connections - terminals | Screw clamp terminal (top) 1…25 mm² rigid without cable end Screw clamp terminal (top) 1…16 mm² flexible Screw clamp terminal (bottom) 1…16 mm² rigid without cable end Screw clamp terminal (bottom) 1…10 mm² flexible |
| Wire stripping length | Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection |
| Tightening torque | Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom |
| earth-leakage protection | Integrated |
| Standards | AS/NZS 61009.1 IEC 61009-1 BS EN 61009-1 IEC 61009-2-2 |
|---|---|
| IP degree of protection | IP20 |
| Tropicalisation | 2 |
| Relative humidity | 95 % at 55 °C |
| Ambient air temperature for operation | -15…60 °C |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.6 cm |
| Package 1 Width | 11.1 cm |
| Package 1 Length | 2.7 cm |
| Package 1 Weight | 219 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 34 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7.764 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 1088 |
| Package 3 Height | 80 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 264.8 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61521 | miniature circuit breaker – C60H – 2 poles – 1 A – C curve
Schneider A9N61502 | miniature circuit breaker – C60H – 1 pole – 2 A – C curve
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
-
0
Schneider A9K24163 | Miniature circuit-breaker, Acti9 iK60N, 1P, 63 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.