Schneider C11N44V100L | circuit breaker ComPacT NSXm N (50 kA at 415 VAC), 4P 4d, 100 A rating Micrologic 4.1 trip unit, EverLink connectors
Schneider C11N44V100L | circuit breaker ComPacT NSXm N (50 kA at 415 VAC), 4P 4d, 100 A rating Micrologic 4.1 trip unit, EverLink connectors
Description
Schneider C11N44V100L: A Comprehensive Guide
Introduction
it is a standout component in the electrical industry, known for its exceptional performance and reliability. In an age where efficiency and durability are paramount, understanding the intricacies of such components is crucial for both professionals and enthusiasts alike.
What is the Schneider C11N44V100L?
it is a high-performance electrical component designed to meet rigorous standards in various applications. Its specifications include robust electrical characteristics and a design that ensures longevity and efficiency.
Key Features
- High Durability: Engineered to withstand harsh conditions.
- Efficiency: Optimized for energy conservation.
- Versatility: Suitable for a wide range of applications.
Applications of Schneider C11N44V100L
Industrial Applications
In the industrial sector, it plays a critical role in ensuring the seamless operation of machinery and systems, contributing to enhanced productivity and safety.
Commercial Uses
From office buildings to shopping centers, this component is integral in maintaining efficient electrical systems, ensuring businesses run smoothly without interruption.
Residential Uses
In homes, it is a reliable choice for various electrical needs, providing peace of mind with its consistent performance and safety features.
Benefits of Using Schneider C11N44V100L
Reliability
One of the standout benefits of it is its reliability. Users can depend on it for consistent performance, minimizing downtime and maintenance costs.
Efficiency
Efficiency is another major benefit. This component is designed to optimize energy use, which can lead to significant cost savings over time.
Cost-effectiveness
Given its durability and efficiency, it is a cost-effective solution, providing long-term value to users.
Technical Specifications
Electrical Characteristics
- Voltage Rating: Designed to handle a wide range of voltages, making it versatile for different applications.
- Current Capacity: Capable of managing substantial electrical loads.
Physical Dimensions
- Compact Design: Ensures easy integration into various systems.
- Durable Construction: Built to last, even in demanding environments.
Environmental Ratings
- Temperature Tolerance: Can operate in extreme temperatures.
- Resistance: Resistant to moisture and dust, enhancing its longevity.
Installation Process
Pre-installation Requirements
Before installing it, ensure you have all necessary tools and have read the installation manual thoroughly.
Step-by-step Installation Guide
- Preparation: Gather all tools and components.
- Positioning: Place the component in the designated spot.
- Connection: Secure all electrical connections as per the manual.
- Testing: Test the component to ensure it is functioning correctly.
Safety Precautions
- Always turn off the power supply before installation.
- Wear appropriate safety gear.
- Follow the installation manual meticulously.
Maintenance and Troubleshooting
Routine Maintenance Tips
- Regularly inspect for signs of wear and tear.
- Clean components to prevent dust buildup.
- Ensure connections remain secure.
Common Issues and Solutions
- Overheating: Check for proper ventilation and load capacity.
- Loose Connections: Regularly tighten all connections.
- Operational Failures: Perform diagnostic tests to identify and rectify issues.
When to Seek Professional Help
If you encounter persistent issues that regular maintenance can’t resolve, it’s best to seek professional assistance to avoid further complications.
Comparing Schneider C11N44V100L with Competitors
Key Competitors
- Brand A
- Brand B
- Brand C
Comparative Analysis
While competitors offer similar features, it stands out due to its superior durability, efficiency, and cost-effectiveness.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 160N |
| product or component type | Earth leakage circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 4D |
| Neutral position | Left |
| [In] rated current | 100 A at 40 °C |
| [Ue] rated operational voltage | 440 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | MicroLogic 4.1 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoIR |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 4.77 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…70 mm², fine stranded copper 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 100 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 40...100 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 200 s at 1.5 x Ir 8 s at 6 x Ir 5 s at 7.2 x Ir |
| Neutral protection settings | 1 x Ir (4D) |
| thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1500 A |
| Earth-leakage protection | Integrated |
| Earth-leakage protection class | Class A Class AC |
| Earth-leakage protection sensitity adjustment type IΔn | Adjustable |
| [IΔn] earth-leakage protection sensitivity adjustment range | 30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A |
| Earth-leakage sensitivity | 30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1 A for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1 A for class AC 3 A for class AC 5 A for class AC |
| Earth-leakage protection time delay adjustement type Δt | Adjustable |
| [Δt] Earth-leakage protection time delay adjustment range | 0 ms 60 ms 150 ms 500 ms 1000 ms |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 144 mm |
| Depth (D) | 80 mm |
| net weight | 1.63 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 15.0 cm |
| Package 1 Width | 13.0 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 1.816 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 7.642 kg |
| Warranty | 18 months |
|---|
Reviews