Schneider A9F76116 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 16A, B curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)
Schneider A9F76116 Description
The Schneider A9F76116 is a highly reliable miniature circuit breaker (MCB) from the Acti9 series, designed to provide excellent protection and efficiency in electrical distribution systems. This MCB is suitable for both residential and commercial applications, ensuring the safety and integrity of electrical circuits.
Schneider A9F76116: Technical Specifications and Features
Technical Specifications:
- Product Range: Acti9
- Product Type: Miniature Circuit Breaker (MCB)
- Number of Poles: 1
- Rated Current: 16 A
- Tripping Curve: C-curve
- Breaking Capacity: 6 kA at 230/400V AC
- Rated Voltage: 230/400V AC
- Frequency: 50/60 Hz
- Standards: IEC/EN 60898-1
Key Features:
- Safety Indicators: The VisiTrip indicators allow for quick identification of tripped circuits, enabling faster maintenance and reducing downtime.
- High Breaking Capacity: With a breaking capacity of 6 kA, the A9F76116 provides reliable protection against short circuits and overloads.
- Ease of Installation: The modular design of the Acti9 series ensures easy installation on DIN rails, facilitating straightforward upgrades and replacements.
- Durability: Constructed from high-quality materials, the A9F76116 ensures long-term reliability and performance.
- Compatibility: This MCB is compatible with a wide range of Acti9 series accessories, such as auxiliary contacts and remote control units, enhancing its functionality.
- Eco-Friendly: Schneider Electric prioritizes sustainability, and the A9F76116 is designed with eco-friendly materials and processes.
Applications:
- Residential Buildings: Provides reliable protection for electrical circuits in homes, safeguarding against overloads and short circuits.
- Commercial Buildings: Ensures the safety and efficiency of electrical systems in offices, shops, and other commercial establishments.
- Industrial Settings: Suitable for small industrial applications where dependable circuit protection is essential.
Benefits of Using Schneider A9F76116
- Enhanced Safety: Clear trip indicators and robust construction minimize the risk of electrical hazards.
- Cost-Effective Maintenance: Easy fault identification and straightforward replacement reduce maintenance costs and downtime.
- Versatility: Suitable for a wide range of applications, offering flexibility and adaptability.
- Long-Term Reliability: High-quality construction ensures longevity, reducing the need for frequent replacements.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 16 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | B |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60898-1 IEC 60947-2 EN 60947-2 EN 60898-1 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 4 x In +/- 20 % |
| [Ics] rated service breaking capacity | 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| Height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| net weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.8 cm |
| Package 1 Width | 7.5 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 108.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 7.8 cm |
| Package 2 Width | 10.0 cm |
| Package 2 Length | 22.0 cm |
| Package 2 Weight | 1.362 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.496 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Be the first to review “Schneider A9F76116 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 16A, B curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)” Cancel reply
Recommended for you
-
0
Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F87140 | Miniature circuit-breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F77320 | Miniature circuit-breaker, Acti9 iC60N, 3P, 20 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9F74104 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 4A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
-
0
Reviews
There are no reviews yet.