schneider A9F87363 | Miniature circuit-breaker, Acti9 iC60H, 3P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Description
schneider A9F87363 | Miniature circuit-breaker, Acti9 iC60H, 3P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
schneider A9F87363 description
Circuit breakers are crucial in safeguarding electrical systems from overcurrents and short circuits. In this article, we’ll take a closer look at the Schneider A9F87363, a miniature circuit breaker (MCB) that offers robust performance and reliability.
Schneider A9F87363
The Schneider A9F87363 is a 1-pole, 63A MCB from the Acti9 series. It features a C curve, designed to protect circuits with moderate inrush currents, such as those used in lighting and distribution systems. This MCB is versatile enough for both residential and commercial use, providing reliable protection and operational efficiency.
How Circuit Breakers Work
Circuit breakers serve as protective devices in electrical systems by automatically interrupting the power supply when an overcurrent or short circuit is detected. They continuously monitor the current flow and trip to stop the electricity when they detect anomalies, preventing damage to the electrical circuit.
Types of Circuit Breakers
There are several types of circuit breakers, including Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), and others. Each type serves a specific purpose, from protecting against overloads and short circuits to detecting residual currents.
Importance in Safety
The importance of circuit breakers in maintaining electrical safety cannot be overstated. They help prevent potential hazards like fires, equipment damage, and electric shocks by interrupting overcurrents and short circuits. Properly functioning circuit breakers are essential for safe electrical systems.
Installation Process
To install a Schneider A9F87363 circuit breaker, follow these steps:
- Turn off the main power: Ensure the main power supply is turned off to avoid any accidents.
- Identify the circuit: Determine the specific circuit where the MCB will be installed.
- Connect the MCB: Securely attach the MCB to the circuit, ensuring all connections are properly tightened and correct.
- Test the installation: Once installed, test the MCB to confirm that it trips and resets as expected.
Maintenance Tips
Maintaining your circuit breaker is crucial for its longevity and effectiveness:
- Periodic testing: Regularly test the MCB to ensure it operates correctly.
- Inspect for damage: Check the MCB for any physical damage or signs of wear and tear.
- Replace faulty units: If the MCB shows any malfunction, replace it promptly to ensure continued safety.
Common FAQs
- What is the difference between an MCB and an RCCB?
- An MCB protects against overloads and short circuits, while an RCCB detects residual currents to prevent electric shocks.
- Can MCBs be used in residential applications?
- Yes, MCBs like the Schneider A9F87363 are suitable for both residential and commercial applications.
- What does the ‘C curve’ mean in an MCB?
- The ‘C curve’ indicates the MCB’s tripping characteristics, suitable for circuits with moderate inrush currents.
- How often should an MCB be tested?
- It is recommended to test MCBs at least once a year to ensure they are functioning properly.
- Are MCBs affected by environmental factors?
- Yes, extreme temperatures and humidity can impact MCB performance, so consider the installation environment carefully.
Conclusion
The Schneider A9F87363 MCB is a robust and reliable solution for protecting electrical circuits from overcurrents and short circuits. With appropriate installation and regular maintenance, it ensures the safety and longevity of electrical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 63 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 EN 60947-2 EN 60898-1 IEC 60898-1 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 125...180 V DC 15 kA 100 % conforming to EN 60947-2 - 125...180 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| net weight | 0.375 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.3 cm |
| Package 1 Width | 5.4 cm |
| Package 1 Length | 8.5 cm |
| Package 1 Weight | 402.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 8.1 cm |
| Package 2 Width | 9.8 cm |
| Package 2 Length | 22.4 cm |
| Package 2 Weight | 1.678 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 44 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 18.946 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F87363
Main Document
Data Sheet : A9F87363
Reviews (0)
Recommended for you
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18470 | Miniature circuit-breaker, Acti9 C120H, 3P, 125 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18369 | Miniature circuit-breaker, Acti9 C120N, 3P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.