Schneider ATV630D22N4 | variable speed drive ATV630, 22kW/30HP, 380…480V, IP21/UL type 1
Schneider ATV630D22N4 | variable speed drive ATV630, 22kW/30HP, 380…480V, IP21/UL type 1
Description
Introduction
The Schneider ATV630D22N4 is a state-of-the-art variable speed drive engineered to enhance industrial processes. Known for its advanced features and robust design, it is a critical component in various industrial applications, ensuring both efficiency and reliability.
What is the Schneider ATV630D22N4?
The Schneider ATV630D22N4 belongs to the Altivar Process 630 series, celebrated for its high performance and energy efficiency. This particular model stands out due to its versatility and scalability, making it suitable for a broad spectrum of applications. Compared to other models in the ATV630 series, the ATV630D22N4 offers specialized features that cater to demanding industrial environments.
Key Features of the Schneider ATV630D22N4
Energy Efficiency
The ATV630D22N4 excels in energy efficiency, designed to significantly reduce energy consumption. This leads to lower operational costs and a minimized carbon footprint, making it an eco-friendly choice for industries.
Flexibility and Scalability
This model is highly flexible and scalable, easily adapting to various industrial needs. Its modular design allows for seamless integration into existing systems and scalability as operational demands increase.
Robust Design
Built to withstand challenging industrial conditions, the ATV630D22N4 features a robust design that ensures durability and longevity. This minimizes downtime and maintenance costs, contributing to sustained productivity.
Technical Specifications
Power Ratings
The ATV630D22N4 offers a range of power ratings to meet diverse application requirements, ensuring it can support various industrial processes efficiently.
Input and Output Voltage
It supports multiple input and output voltage ranges, providing the flexibility needed for different industrial settings.
Frequency Range
Operating within a wide frequency range, it is suitable for various types of machinery and equipment, enhancing its versatility.
Applications of the Schneider ATV630D22N4
Industrial Automation
In industrial automation, it plays a pivotal role in improving the efficiency and performance of automated systems, ensuring precise control and smooth operation of machinery.
HVAC Systems
it is widely utilized in HVAC systems, optimizing energy use and maintaining consistent performance, which is crucial for climate control and ventilation systems.
Water and Wastewater Management
In water and wastewater management, it ensures efficient and reliable operation of pumps and other equipment, contributing to effective resource management and sustainability.
Advantages of Using Schneider ATV630D22N4
Cost Savings
By significantly reducing energy consumption and maintenance costs, it offers considerable cost savings over its lifecycle, making it a cost-effective solution for industries.
Enhanced Operational Efficiency
With precise control and advanced features, it enhances operational efficiency, ensuring smooth and uninterrupted industrial processes.
Reduced Environmental Impact
Its energy-efficient design helps in reducing the environmental impact of industrial operations, supporting sustainability goals and compliance with environmental regulations.
Installation and Setup
Pre-Installation Considerations
Before installing the ATV630D22N4, it is essential to consider factors such as the installation environment and compatibility with existing systems to ensure a successful setup.
Step-by-Step Installation Guide
- Prepare the installation site.
- Securely mount the drive.
- Connect the electrical wiring following the manual’s instructions.
- Configure the drive settings according to the specific application requirements.
Initial Setup and Configuration
Post-installation, the initial setup involves configuring the drive parameters to match the application’s needs, ensuring optimal performance and efficiency.
Maintenance and Troubleshooting
Routine Maintenance Tips
Regular maintenance is vital for the longevity and optimal performance of it. This includes periodic inspections, cleaning, and ensuring all connections are secure.
Common Issues and Solutions
Common issues with it include overheating and communication errors. These can typically be resolved through troubleshooting steps provided in the user manual or by contacting Schneider’s technical support.
Support and Resources
Schneider offers extensive support and resources for it, including technical support, online resources, and comprehensive manuals to assist with maintenance and troubleshooting.
Energy Management with ATV630D22N4
Energy Monitoring Capabilities
it features built-in energy monitoring capabilities, allowing users to track and optimize energy usage effectively.
Integration with Energy Management Systems
It can be integrated with broader energy management systems, providing a comprehensive solution for monitoring and managing energy efficiency.
Benefits of Energy Management
Effective energy management with it leads to reduced energy costs, improved operational efficiency, and enhanced sustainability, making it an excellent choice for industries focused on energy conservation.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Altivar Process ATV600 |
|---|---|
| product or component type | Variable speed drive |
| Product specific application | Process and utilities |
| Device short name | ATV630 |
| variant | Standard version |
| product destination | Asynchronous motors Synchronous motors |
| EMC filter | Integrated with 50 m conforming to EN/IEC 61800-3 category C2 Integrated with 150 m conforming to EN/IEC 61800-3 category C3 |
| IP degree of protection | IP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529 |
| [Us] rated supply voltage | 380...480 V |
| Degree of protection | UL type 1 conforming to UL 508C |
| Type of cooling | Forced convection |
| Supply frequency | 50...60 Hz - 5...5 % |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Motor power kW | 22 kW (normal duty) 18.5 kW (heavy duty) |
| Motor power hp | 30 hp normal duty 25 hp heavy duty |
| Line current | 39.6 A at 380 V (normal duty) 34.4 A at 480 V (normal duty) 34.1 A at 380 V (heavy duty) 29.9 A at 480 V (heavy duty) |
| Prospective line Isc | 50 kA |
| Apparent power | 28.6 kVA at 480 V (normal duty) 24.9 kVA at 480 V (heavy duty) |
| Continuous output current | 46.3 A at 4 kHz for normal duty 39.2 A at 4 kHz for heavy duty |
| Asynchronous motor control profile | Optimized torque mode Constant torque standard Variable torque standard |
| Synchronous motor control profile | Permanent magnet motor Synchronous reluctance motor |
| Speed drive output frequency | 0.1…500 Hz |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2...12 kHz adjustable 4...12 kHz with derating factor |
| Safety function | STO (safe torque off) SIL 3 |
| Discrete input logic | 16 preset speeds |
| Communication port protocol | Modbus TCP Ethernet Modbus serial |
| Option card | Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink |
| mounting mode | Wall mount |
|---|---|
| Maximum transient current | 50.9 A during 60 s (normal duty) 58.8 A during 60 s (heavy duty) |
| Network number of phases | 3 phases |
| Discrete output number | 0 |
| Discrete output type | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA Relay outputs R1A, R1B, R1C 30 V DC 3000 mA Relay outputs R2A, R2C 250 V AC 5000 mA Relay outputs R2A, R2C 30 V DC 5000 mA Relay outputs R3A, R3C 250 V AC 5000 mA Relay outputs R3A, R3C 30 V DC 5000 mA |
| Output voltage | <= power supply voltage |
| Permissible temporary current boost | 1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty) |
| Motor slip compensation | Adjustable Not available in permanent magnet motor law Automatic whatever the load Can be suppressed |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s |
| Physical interface | Ethernet 2-wire RS 485 |
| Braking to standstill | By DC injection |
| Protection type | Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
| Transmission rate | 10, 100 Mbits 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
| Frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
| Transmission frame | RTU |
| Electrical connection | Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16 Motor: screw terminal 16 mm²/AWG 6 Line side: screw terminal 10...16 mm²/AWG 8...AWG 6 |
| Connector type | RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP RJ45 (on the remote graphic terminal) for Modbus serial |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP |
| Number of addresses | 1…247 for Modbus serial |
| Method of access | Slave Modbus TCP |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
| Local signalling | 3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage |
| Width | 211 mm |
| Height | 546 mm |
| Depth | 232 mm |
| net weight | 14.3 kg |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits |
| Discrete input number | 8 |
| Discrete input type | DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Input compatibility | DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Discrete input logic | Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1) |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits Software-configurable current DQ-, DQ+: 30 V DC Software-configurable current DQ-, DQ+: 100 mA |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AO1) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AO1, AO2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Isolation | Between power and control terminals |
| Maximum output frequency | 500 kHz |
| Maximum input current | 39.6 A |
| Variable speed drive application selection | Building - HVAC compressor centrifugal Food and beverage processing other application Mining mineral and metal fan Mining mineral and metal pump Oil and gas fan Water and waste water other application Building - HVAC screw compressor Food and beverage processing pump Food and beverage processing fan Food and beverage processing atomization Oil and gas electro submersible pump (ESP) Oil and gas water injection pump Oil and gas jet fuel pump Oil and gas compressor for refinery Water and waste water centrifuge pump Water and waste water positive displacement pump Water and waste water electro submersible pump (ESP) Water and waste water screw pump Water and waste water lobe compressor Water and waste water screw compressor Water and waste water compressor centrifugal Water and waste water fan Water and waste water conveyor Water and waste water mixer |
| Motor power range AC-3 | 15…25 kW at 380…440 V 3 phases 15…25 kW at 480…500 V 3 phases |
| Quantity per set | 1 |
| enclosure mounting | Wall mounted |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
|---|---|
| Noise level | 59.5 dB conforming to 86/188/EEC |
| Power dissipation in W | Natural convection: 68 W at 380 V, switching frequency 4 kHz Forced convection: 505 W at 380 V, switching frequency 4 kHz |
| Volume of cooling air | 215 m3/h |
| Operating position | Vertical +/- 10 degree |
| Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -15…50 °C (without derating) 50…60 °C (with derating factor) |
| Ambient air temperature for storage | -40…70 °C |
| Operating altitude | <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m |
| Product certifications | ATEX zone 2/22 CSA TÜV DNV-GL UL ATEX INERIS |
| marking | CE |
| Standards | UL 508C EN/IEC 61800-3 EN/IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
| Overvoltage category | III |
| Regulation loop | Adjustable PID regulator |
| Noise level | 59.5 dB |
| Pollution degree | 2 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 33.500 cm |
| Package 1 Width | 26.000 cm |
| Package 1 Length | 73.500 cm |
| Package 1 Weight | 17.580 kg |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 90.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 80.932 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider NSYSFV20 | Set of 4 vertical uprights for Spacial SF enclosure. Height: 2000 mm. RAL 7035.
Schneider NSYCRNG1210300D | Spacial CRNG dbl plain door w/o mount.plate. H1200xW1000xD300 IP55 IK10 RAL7035
Schneider NSYSM1810402D | PanelSeT SM compact enclosure without mounting plate – 1800x1000x400 mm
Schneider NSYSM20640 | PanelSeT SM compact enclosure without mounting plate – 2000x600x400 mm
Schneider NSYSM1612402D | PanelSeT SM compact enclosure without mounting plate – 1600x1200x400 mm
-
0
Reviews
There are no reviews yet.