Schneider G25B3A200 | Circuit breaker, GoPact MCCB 250, 3 poles, 25kA at 415VAC, 200A rating, TMD trip unit, adjustable thermal protection
Schneider G25B3A200 | Circuit breaker, GoPact MCCB 250, 3 poles, 25kA at 415VAC, 200A rating, TMD trip unit, adjustable thermal protection
Description
Schneider G25B3A200 | Circuit breaker, GoPact MCCB 250, 3 poles, 25kA at 415VAC, 200A rating, TMD trip unit, adjustable thermal protection
1. Technical Specifications G25B3A200
-
Product Name:
Molded Case Circuit Breaker (MCCB) -
Model Number:
G25B3A200 -
Product Series:
GoPact MCCB 250 -
Rated Current (In):
200 A -
Number of Poles:
3 poles -
Rated Operating Voltage (Ue):
Up to 415 VAC, 50/60 Hz -
Rated Breaking Capacity (Icu):
25 kA at 415 VAC (as per IEC 60947-2) -
Trip Unit Type:
TMD (Thermal Magnetic) -
Thermal Protection:
Adjustable thermal trip — allows fine-tuning to match system overload levels -
Magnetic Protection:
Fixed setting for short-circuit protection -
Mounting Type:
Fixed installation within switchboards or enclosures -
Terminal Configuration:
Front-connected terminals for cable lugs or bars -
Operating Environment:
-
Ambient Temperature: -25°C to +70°C
-
Storage Temperature: -40°C to +85°C
-
Degree of Protection:
IP20 (can be increased with proper enclosure) -
Compliance & Certifications:
-
IEC 60947-2
-
CE certified
-
RoHS compliant
-
REACh compliant
2. Key Features G25B3A200
-
High Interrupting Capacity:
Withstands fault currents up to 25kA at 415 VAC, suitable for medium-risk distribution systems. -
Adjustable Thermal Trip:
Ensures proper overload protection based on actual system loads, enhancing safety and performance. -
Fast Short-Circuit Response:
Fixed magnetic trip reacts instantly to high current faults, preventing damage to downstream equipment. -
Reliable Circuit Protection:
Provides robust and consistent protection for commercial and industrial installations. -
Compact and Space-Saving Design:
Helps optimize panel layout while delivering high performance in a small footprint. -
Durable Build:
Engineered for longevity and reliability in harsh industrial and commercial environments. -
Easy Integration:
Compatible with Schneider Electric GoPact accessories like rotary handles, auxiliary contacts, and alarms. -
Clear ON/OFF Indication:
Helps ensure proper operational visibility for safe and easy status checks. -
Maintenance-Friendly Design:
Front access for wiring and maintenance; simplified mounting reduces installation time. -
Standardized for Global Applications:
Complies with international electrical standards for wide adoption and reliable use.
3. Typical Applications G25B3A200
-
Industrial Electrical Panels:
Protects motors, machines, and control panels in manufacturing facilities. -
Main and Sub-Distribution Boards:
Ideal for commercial and infrastructure power distribution systems. -
Large HVAC Installations:
Used to safeguard compressors, chillers, and air handling units. -
Renewable Energy Systems:
Suitable for solar AC protection and hybrid power systems. -
Hospitals and Data Centers:
Ensures stable protection in critical power systems. -
Water Treatment and Utilities:
Provides secure breaker functionality for pumps, blowers, and control gear. -
Transportation and Airports:
Installed in systems that require reliable breaker performance under dynamic load conditions. -
OEM Equipment and Switchboards:
Integrated into customized assemblies and pre-engineered panels.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | GoPact MCCB |
|---|---|
| product or component type | Circuit breaker |
| Product name | GoPact MCCB 250 |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 200 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 25 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Performance level | B 25 kA 380/415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 440 V AC conforming to EN/IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 25 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Mechanical durability | 25000 cycles |
| Electrical durability | 8000 cycles at 415 V In |
| Power dissipation per pole | 25 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Screw terminals |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 200 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 12 x In |
| Width (W) | 105 mm |
| Height (H) | 165 mm |
| Depth (D) | 90 mm |
| net weight | 1.9 kg |
| Colour | Grey (RAL 7035) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H |
|---|---|
| Overvoltage category | III |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C |
| ambient air temperature for storage | -35…85 °C |
| Operating altitude | 0...2000 m without derating 2000...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 18.3 cm |
| Package 1 Width | 14.1 cm |
| Package 1 Length | 20.4 cm |
| Package 1 Weight | 3100 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 6.641 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 24 |
| Package 3 Height | 105 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 88.192 kg |
Main documents
Main documents
Reviews (0)
Recommended for you
Schneider A9N61521 | miniature circuit breaker – C60H – 2 poles – 1 A – C curve
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18446 | Miniature circuit-breaker, Acti9 C120H, 1P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9K24316 | Miniature circuit-breaker, Acti9 iK60N, 3P, 16 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.