Schneider G80N3TM630 | Circuit breaker, GoPact MCCB 800, 3 poles, 50kA at 415VAC, 630A rating, TMD trip unit, adjustable thermal protection
Schneider G80N3TM630 | Circuit breaker, GoPact MCCB 800, 3 poles, 50kA at 415VAC, 630A rating, TMD trip unit, adjustable thermal protection
Description
Technical Specifications G80N3TM630
-
Product Model: Schneider G80N3TM630
-
Type: MCCB – Molded Case Circuit Breaker
-
Number of Poles: 3 poles
-
Breaking Capacity: 50 kA at 415V AC
-
Rated Current: 630 Amps
-
Trip Unit: TMD (Thermal Magnetic Device)
-
Thermal Protection: Adjustable
-
Magnetic Protection: Fixed
-
Operating Voltage Range: Up to 690V AC
-
Frequency: 50/60 Hz
-
Insulation Voltage: 800V
-
Rated Impulse Withstand Voltage (Uimp): 8 kV
-
Utilization Category: A (as per IEC 60947-2)
-
Degree of Protection: IP40 (when mounted in a suitable enclosure)
-
Standards: IEC 60947-2 compliant
Key Features and Benefits
-
Robust Protection System:
Provides both thermal (overload) and magnetic (short circuit) protection to ensure safe operation under fault conditions. -
Adjustable Thermal Trip:
The thermal protection can be fine-tuned to match the specific load characteristics and system requirements, offering flexibility in diverse installations. -
Reliable Breaking Capacity:
With a 50 kA breaking capacity at 415VAC, it offers dependable protection in medium-to-high fault level environments. -
Efficient Design:
Compact and modular design helps save panel space and simplifies integration into existing switchboards or panels. -
Maintenance-Friendly:
Designed with installer convenience in mind, offering accessible terminals, visible indicators, and straightforward mounting. -
Durable Build Quality:
Manufactured with high-quality materials that ensure long service life and reliable performance under demanding conditions.
Typical Applications
-
Industrial switchboards for machinery and plant equipment
-
Power distribution systems in commercial buildings, offices, and shopping centers
-
Utility panels in warehouses and factories
-
Backup and generator protection systems
-
Energy systems in infrastructure projects such as airports, hospitals, and data centers
-
Renewable energy installations, including solar PV arrays and small wind systems
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | GoPact MCCB |
|---|---|
| product or component type | Circuit breaker |
| Product name | GoPact MCCB 800 |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 630 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 50 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 65 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Performance level | N 50 kA 380/415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 440 V AC conforming to EN/IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 50 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 65 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Mechanical durability | 15000 cycles |
| Electrical durability | 3000 cycles at 415 V In |
| Power dissipation per pole | 60 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Screw terminals |
| Connection pitch | 60 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 630 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 10 x In |
| Width (W) | 180 mm |
| Height (H) | 250 mm |
| Depth (D) | 105 mm |
| net weight | 6.9 kg |
| Colour | Grey (RAL 7035) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H |
|---|---|
| Overvoltage category | III |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C |
| ambient air temperature for storage | -35…85 °C |
| Operating altitude | 0...2000 m without derating 2000...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 18 cm |
| Package 1 Width | 27 cm |
| Package 1 Length | 29 cm |
| Package 1 Weight | 11050 g |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 105 cm |
| Package 2 Width | 60 cm |
| Package 2 Length | 80 cm |
| Package 2 Weight | 146.392 kg |
Reviews