Schneider GV2ME02 | Motor circuit breaker, TeSys GV2, 3P, 0.16-0.25 A, thermal magnetic, screw clamp terminals
Schneider GV2ME02 | Motor circuit breaker, TeSys GV2, 3P, 0.16-0.25 A, thermal magnetic, screw clamp terminals
Description
Schneider GV2ME02 | Motor circuit breaker, TeSys GV2, 3P, 0.16-0.25 A, thermal magnetic, screw clamp terminals
The Schneider GV2ME02 is a compact, reliable motor circuit breaker from the TeSys GV2 range, offering precise protection for motors in the 0.16 to 0.25 Ampere range. It uses thermal-magnetic technology to ensure both overload and short-circuit protection in one device.
Key Features:
-
Product Name: GV2ME02
-
Brand: Schneider Electric
-
Range: TeSys GV2
-
Product Type: Motor Circuit Breaker
-
Technology: Thermal magnetic protection
-
Number of Poles: 3P (Three poles)
-
Current Range: 0.16 to 0.25 A
-
Terminal Type: Screw clamp terminals
-
Manual Operation: Start/Stop push buttons on front panel
Main Applications:
-
Direct-on-line motor starting and protection
-
Overload and short-circuit protection for small motors
-
Ideal for use in industrial control panels, pumps, fans, and machine tools
Advantages:
-
Thermal Protection: Detects and trips in case of motor overload (slow rise in current)
-
Magnetic Protection: Reacts quickly to short circuits (instantaneous trip)
-
Compact Design: Fits easily in panels, saves space
-
Easy to Use: Simple adjustment dial for current setting
-
Reliable: Proven Schneider quality and performance
Technical Specifications:
-
Current Setting Range: 0.16 – 0.25 A
-
Rated Operational Voltage: Up to 690V AC
-
Breaking Capacity: High short-circuit interrupting capacity
-
Mounting: DIN rail or screw mounting
-
Control: Manual start/stop buttons
-
Standards Compliance: IEC 60947-2, IEC 60947-4-1
Typical Use Cases:
-
Protection for fractional horsepower motors
-
Small pumps and ventilators
-
Laboratory equipment and compact machinery
-
Motor control centers (MCCs)
Benefits for Installers and Panel Builders:
-
Tool-less wiring possible with screw clamp terminals
-
Fast installation and commissioning
-
Compatible with Schneider accessories (enclosures, auxiliary contacts, busbars)
-
Improves uptime by reducing nuisance trips and allowing easy manual reset
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys Deca |
|---|---|
| Product name | TeSys GV2 TeSys Deca |
| Product or component type | Motor circuit breaker |
| Device short name | GV2ME |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
| Poles description | 3P |
|---|---|
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-4-1 |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate) |
| Motor power kW | 0.06 kW at 400/415 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| control type | Push-button |
| [In] rated current | 0.25 A |
| Thermal protection adjustment range | 0.16…0.25 A conforming to IEC 60947-4-1 |
| Magnetic tripping current | 2.4 A |
| [Ith] conventional free air thermal current | 0.25 A conforming to IEC 60947-4-1 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 § 7-1-6 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Tightening torque | 1.7 N.m - on screw clamp terminal |
| Width | 45 mm |
| height | 89 mm |
| Depth | 78.5 mm |
| Net weight | 0.26 kg |
| Colour | Dark grey |
| Standards | EN/IEC 60947-2 EN/IEC 60947-4-1 |
|---|---|
| product certifications | CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV RINA DNV-GL UKCA |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | Conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz |
| Operating altitude | 2000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.800 cm |
| Package 1 Width | 9.300 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 231.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.872 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider GV2ME06 | Motor circuit breaker, TeSys GV2, 3P, 1-1.6 A, thermal magnetic, screw clamp terminals
Schneider GV2ME20 | Motor circuit breaker, TeSys GV2, 3P, 13-18 A, thermal magnetic, screw clamp terminals
Schneider GV2G454 | Linergy FT – Comb busbar – 63 A – 4 tap-offs – 54 mm pitch
-
0
Reviews
There are no reviews yet.