Schneider LC1E80M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,80A,220V AC coil,50Hz
Description
Schneider LC1E80M5| Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,80A,220V AC coil,50Hz
Schneider LC1E80M5 | Contactor, EasyPact TVS, 3P (3NO), AC-3, ≤440V, 80A, 220V AC Coil, 50Hz
1. Introduction
The Schneider LC1E80M5 is a high-performance 3-pole (3NO) contactor from the EasyPact TVS series, designed for reliable motor control and power switching. It is rated for AC-3 applications up to 440V and can handle currents up to 80A. With a 220V AC coil (50Hz), this contactor ensures efficient operation in industrial environments.
2. Key Features
-
Rated Current: 80A (AC-3)
-
Voltage Rating: ≤440V
-
Number of Poles: 3 (3 Normally Open – 3NO)
-
Coil Voltage: 220V AC, 50Hz
-
Durable and High Electrical Endurance
-
Compact Design for Space-Saving Installations
-
Built-in Auxiliary Contacts for Control Circuit Integration
-
Easy Mounting & Compatibility with Overload Relays
3. Technical Specifications
-
Product Series: EasyPact TVS
-
Utilization Category: AC-3 (Motor control applications)
-
Rated Current (Ie): 80A
-
Operating Voltage: ≤440V
-
Coil Voltage: 220V AC, 50Hz
-
Number of Poles: 3P (3NO)
-
Mechanical Durability: Up to 10 million operations
-
Electrical Durability: Up to 1 million operations (AC-3)
-
Operating Temperature: -5°C to +55°C
-
Compliance Standards: IEC 60947-4-1
4. Applications
The Schneider LC1E80M5 contactor is widely used in industrial and commercial applications, including:
-
Motor Control – Switching and protecting motors in various industries
-
HVAC Systems – Controlling compressors, fans, and pumps
-
Pumping Stations – Ensuring smooth operation of water and fluid pumps
-
Lighting Control – Handling large lighting loads in commercial buildings
-
Industrial Automation – Integrating into automated control panels
5. Benefits
-
High Performance & Reliability – Ensures long-lasting operation in demanding conditions
-
Compact & Space-Saving – Ideal for panel installations
-
Versatile Applications – Suitable for various industrial control and power switching needs
-
Easy Maintenance – Simple wiring and replacement process
-
Seamless Integration – Works well with Schneider overload relays for enhanced motor protection
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Easy TeSys |
|---|---|
| Range of product | Easy TeSys Control |
| Product or component type | Contactor |
| Device short name | LC1E |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-3e AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 80 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <55 °C) at <= 440 V AC AC-3e for power circuit 110 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 220 V AC 50 Hz |
| Motor power kW | 22 kW at 220...230 V AC 50/60 Hz 37 kW at 380...400 V 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 45 kW at 660...690 V |
|---|---|
| Pole contact composition | 3 NO |
| [Ith] conventional free air thermal current | 110 A (at 55 °C) for power circuit |
| Irms rated making capacity | 800 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Rated breaking capacity | 640 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 640 A 40 °C - 10 s for power circuit 320 A 40 °C - 60 s for power circuit 135 A 40 °C - 600 s for power circuit |
| Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit |
| Average impedance | 0.8 mOhm - Ith 110 A 50 Hz for power circuit |
| Power dissipation per pole | 5.1 W AC-3 9.7 W AC-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
| Mechanical durability | 3000000 cycles |
| Electrical durability | 350000 cycles AC-1 900000 cycles AC-3 |
| Control circuit type | AC at 50 Hz |
| Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50 Hz 0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz |
| Inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 6…10 W for control circuit |
| Operating time | 20...35 ms on closing 6...30 ms on opening |
| Maximum operating rate | 1200 cyc/h 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 12 N.m |
| Auxiliary contact composition | 1 NO + 1 NC |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
| Mounting support | Plate DIN rail |
| Standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 |
|---|---|
| Product certifications | CE EAC |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms) |
| Height | 127 mm |
| Width | 85 mm |
| Depth | 121 mm |
| Net weight | 1.52 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.000 cm |
| Package 1 Width | 15.000 cm |
| Package 1 Length | 15.500 cm |
| Package 1 Weight | 1.537 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 5 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.190 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 40 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 75.000 kg |
| Warranty | 18 months |
|---|
Reviews