Schneider LV563306 | circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 600 A rating thermal magnetic TM-D trip unit, 3P 3d
Schneider LV563306 | circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 600 A rating thermal magnetic TM-D trip unit, 3P 3d
Description
Schneider LV563306 | circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 600 A rating thermal magnetic TM-D trip unit, 3P 3d
Technical Specifications:
-
Model Number: LV563306
-
Product Range: EasyPact CVS630F
-
Rated Current (In): 600 A
-
Breaking Capacity: 36 kA at 415 VAC
-
Number of Poles: 3 poles (3P, 3d)
-
Trip Unit Type: TM-D (Thermal-Magnetic, fixed settings)
-
Frequency: 50/60 Hz
-
Rated Insulation Voltage: Up to 690 V AC
-
Standard Compliance: IEC 60947-2
-
Mounting: Fixed, suitable for panel installation
-
Device Type: Molded Case Circuit Breaker (MCCB)
Key Features:
-
High breaking capacity of 36 kA ensures safety in systems with significant fault levels
-
Fixed thermal-magnetic (TM-D) trip unit for straightforward, reliable protection
-
600 A rating allows for use in medium to large-scale power distribution setups
-
3-pole configuration suitable for three-phase systems
-
Compact and robust design for easier integration in switchboards
-
Compatible with a variety of Schneider Electric accessories for monitoring and control
-
Ideal for cost-effective protection without compromising performance
Applications:
-
Main protection in low-voltage distribution panels
-
Industrial facilities requiring reliable, mid-range fault current protection
-
Commercial buildings, warehouses, and data centers
-
Electrical systems with high load demands and moderate fault level exposure
-
Protection of cables and connected equipment from overloads and short circuits
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS400...630 |
| Product name | EasyPact CVS |
| Device short name | CVS630F |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 600 A at 40 °C |
| Network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 600 A at 40 °C |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| Network frequency | 50/60 Hz |
| Breaking capacity code | F |
| [Ics] rated service breaking capacity | 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 23 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 15000 cycles |
| Electrical durability | 4000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Thermal protection adjustment range | 420…600 A |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Adjustable |
| instantaneous pick-up adjustment range | 4...8 x In |
| Contact position indicator | Yes |
| Mounting support | Backplate |
| Mounting mode | Fixed |
| Upside connection | Front |
| downside connection | Front |
| Connections - terminals | Screw connection |
| Connection pitch | 45 mm |
| Compatibility code | CVS630 |
| Width | 140 mm |
| Depth | 110 mm |
| Height | 255 mm |
| Net weight | 5.2 kg |
| Standards | EN 60947-2 IEC 60947-2 |
|---|---|
| Product certifications | IEC GOST |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 15.000 cm |
| Package 1 Width | 15.500 cm |
| Package 1 Length | 29.000 cm |
| Package 1 Weight | 5.318 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 40.000 cm |
| Package 2 Length | 60.000 cm |
| Package 2 Weight | 16.604 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 12 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 78.416 kg |
Main Document
Main Document
Data Sheet : LV563306
Main Document
Data Sheet : LV563306
Reviews (0)
Recommended for you
Schneider A9N61506 | miniature circuit breaker – C60H – 1 pole – 6 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18357 | Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
-
0
Reviews
There are no reviews yet.