Schneider RE22R1QCMU | Modular timing relay, 8 A, 0.05 s…300 h, 1 CO, star delta , 24…240 V AC/DC
Description
Schneider RE22R1QCMU | Modular timing relay, 8 A, 0.05 s…300 h, 1 CO, star delta , 24…240 V AC/DC
Introduction
The Schneider RE22R1QCMU modular timing relay is engineered to provide accurate timing control in diverse scenarios. Whether it’s managing star-delta configurations or handling timing sequences ranging from milliseconds to hours, this relay excels in ensuring smooth operation within electrical systems.
Features
Timing Capabilities
One of the key highlights of the Schneider RE22R1QCMU relay is its impressive timing range, spanning from 0.05 seconds to 300 hours. This extensive range allows for precise control over time-sensitive operations, contributing to enhanced efficiency and reliability in industrial processes.
Electrical Specifications
With a capacity to handle up to 8 amps and featuring 1 CO (changeover) contact, this relay proves to be a robust solution for controlling electrical circuits. It operates seamlessly within a voltage range of 24 to 240 volts AC/DC, making it adaptable to various power systems commonly found in industrial setups.
Applications
The versatility of the Schneider RE22R1QCMU relay makes it a valuable asset in numerous applications. From controlling motor start-up sequences in machinery to managing lighting systems based on specific time intervals, its utility extends across diverse industrial sectors.
Installation
Installing the Schneider RE22R1QCMU relay involves careful wiring and setup procedures. Following manufacturer guidelines and ensuring proper insulation and connection integrity are crucial steps to guarantee its optimal performance and longevity.
Troubleshooting
Despite its reliability, occasional issues may arise with the Schneider RE22R1QCMU relay. Common troubleshooting steps include checking for loose connections, verifying input/output configurations, and consulting technical manuals for error codes or indicators.
Maintenance
Regular maintenance is vital to uphold the performance and safety standards of the Schneider RE22R1QCMU relay. Conducting routine checks for dust accumulation, monitoring temperature levels during operation, and replacing worn-out components as needed are essential practices to prolong its lifespan and prevent unexpected failures.
Conclusion
In conclusion, the Schneider RE22R1QCMU modular timing relay encapsulates precision, reliability, and adaptability, making it a preferred choice for engineers and technicians in the electrical domain. Its robust features, wide-ranging applications, and ease of maintenance underscore its significance in optimizing industrial processes.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Harmony Timer Relays |
|---|---|
| Discrete output type | Relay |
| Product or component type | Modular timing relay |
| Device short name | RE22 |
| Nominal output current | 8 A |
| Contacts type and composition | 1 C/O timed contact, cadmium free |
|---|---|
| Time delay type | Star-delta |
| Time delay range | 10...100 s 3...30 s 0.1...1 s 0.3...3 s 0.05...0.5 s 1...10 s 30...300 s |
| Control type | Rotary knob Diagnostic button |
| [Us] rated supply voltage | 24 V DC 24...240 V AC 50/60 Hz |
| Release input voltage | <= 2.4 V |
| Voltage range | 0.85...1.1 Us |
| Supply frequency | 50...60 Hz +/- 5 % |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing |
| Repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
| Temperature drift | +/- 0.05 %/°C |
| Voltage drift | +/- 0.2 %/V |
| Setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
| Time delay type | Star-delta - Qc-Star-delta relay (1 CO output) |
| Insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
| Recovery time | 120 ms on de-energisation |
| Immunity to microbreaks | 10 ms |
| Power consumption in VA | 35 VA at 240 V AC |
| Power consumption in W | 0.6 W at 24 V DC |
| Switching capacity in VA | 2000 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 8 A |
| Maximum switching voltage | 250 V AC |
| Electrical durability | 100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
| Mechanical durability | 10000000 cycles |
| Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1 |
| Power on delay | 100 ms |
| Creepage distance | 4 kV/3 conforming to IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Safety reliability data | MTTFd = 285.3 years B10d = 270000 |
| Mounting position | Any position |
| Mounting support | 35 mm DIN rail conforming to IEC 60715 |
| Status LED | LED backlight green (steady) for dial pointer indication LED yellow (steady) for output relay energised LED yellow (fast flashing) for timing in progress and output relay de-energised LED yellow (slow flashing) for timing in progress and output relay energised |
| Function available | Qc-Star-delta relay (1 CO output)-1 C/O |
| Width | 22.5 mm |
| Net weight | 0.08 kg |
| Control type | With test button |
| Number of functions | 1 |
| Dielectric strength | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1 |
|---|---|
| Standards | UL 508 IEC 61812-1 |
| Directives | 2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive |
| Product certifications | GL CE CCC EAC UL CSA RCM |
| Ambient air temperature for operation | -20…60 °C |
| Ambient air temperature for storage | -40…70 °C |
| IP degree of protection | IP40 housing: conforming to IEC 60529 IP50 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Vibration resistance | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn not operating for 11 ms conforming to IEC 60068-2-27 5 gn in operation for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 95 % at 25…55 °C |
| Electromagnetic compatibility | Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.5 cm |
| Package 1 Width | 8.4 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 90.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 40 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 4.14 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 640 |
| Package 3 Height | 80.0 cm |
| Package 3 Width | 80.0 cm |
| Package 3 Length | 60.0 cm |
| Package 3 Weight | 73.38 kg |
Reviews