Schneider RM35TF30 | Multifunction phase control relay RM35-T – range 194..528 V AC
Description
Schneider RM35TF30 | Multifunction phase control relay RM35-T – range 194..528 V AC
Outline of the Article
- Introduction to Schneider RM35TF30
- Brief overview of the RM35TF30 relay
- Applications and Importance
- Discuss the applications and significance of the relay in various industries
- Technical Specifications
- Detail the technical specifications of the RM35TF30 relay
- Features and Benefits
- Highlight the key features and benefits of using this relay
- Installation and Setup
- Step-by-step guide on how to install and set up the RM35TF30 relay
- Troubleshooting and Maintenance
- Tips on troubleshooting common issues and regular maintenance of the relay
- Comparison with Other Relays
- Compare the RM35TF30 relay with similar products in the market
- Customer Reviews and Feedback
- Include real customer reviews and feedback about the RM35TF30 relay
- Conclusion
- Summarize the key points and emphasize the importance of the RM35TF30 relay
Schneider RM35TF30 | Multifunction Phase Control Relay RM35-T – Range 194..528 V AC Description
The Schneider RM35TF30 is a multifunction phase control relay designed for a wide range of applications in industrial and commercial settings. This versatile relay offers precise control over voltage levels, making it an essential component in electrical systems.
Introduction to Schneider RM35TF30
The RM35TF30 relay from Schneider Electric is known for its reliability and performance in managing voltage levels within a specified range. Whether used in monitoring, control, or protection applications, this relay excels in ensuring stable power supply conditions.
Applications and Importance
In industries such as manufacturing, automation, and energy management, the RM35TF30 plays a crucial role in maintaining optimal voltage levels. Its ability to handle voltages ranging from 194 to 528 V AC makes it suitable for a variety of equipment and machinery.
Technical Specifications
- Voltage Range: 194 to 528 V AC
- Control Function: Phase control relay
- Operating Temperature: -20°C to +60°C
- Mounting: DIN rail mounting
- Output Contacts: 1 NO + 1 NC
Features and Benefits
- Precise voltage control for stable operations
- Compact design for easy integration into control panels
- LED indicators for status monitoring
- DIN rail mounting for convenient installation
Installation and Setup
Installing the RM35TF30 relay is straightforward, requiring basic electrical knowledge. Start by mounting the relay on a DIN rail and connecting the input and output terminals as per the provided manual. Configure the relay settings to match your specific requirements.
Troubleshooting and Maintenance
Regular maintenance ensures the optimal performance of the RM35TF30 relay. Periodically check for loose connections, clean the relay’s contacts, and verify voltage readings to detect any anomalies early on. Refer to the user manual for detailed troubleshooting steps.
Comparison with Other Relays
Compared to traditional relays, the RM35TF30 stands out with its wider voltage range and precise control capabilities. It offers a cost-effective solution without compromising on quality or performance.
Customer Reviews and Feedback
Customers praise the RM35TF30 for its reliability and ease of use. Many highlight its role in preventing voltage fluctuations and protecting sensitive equipment, showcasing its value in various industrial environments.
Conclusion
In conclusion, the Schneider RM35TF30 multifunction phase control relay is a dependable choice for managing voltage levels effectively. Its advanced features, ease of installation, and robust performance make it a preferred option for diverse applications.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Harmony Control Relays |
|---|---|
| Relay type | Multifunction control relay |
| Product or component type | 3-phase control relay |
| Product specific application | For 3-phase supply |
| Relay name | RM35TF |
| Relay monitored parameters | Undervoltage and overvoltage in window mode Phase sequence Phase failure detection Asymmetry |
| Measurement range | 220...480 V AC |
| time delay | Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Output contacts | 2 C/O |
| Nominal output current | 5 A |
| Contacts type and composition | 2 C/O |
| [Uc] control circuit voltage | 220...480 V |
| [Un] rated nominal voltage | , self-powered |
|---|---|
| Supply voltage limits | 194…528 V AC, 3 phases |
| Reset time | 1500 ms at 480 V |
| Maximum switching voltage | 250 V AC 250 V DC |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC 5 A DC |
| Control circuit voltage limits | - 12 % + 10 % Un |
| Power consumption in VA | 0…22 VA at 400 V AC 50 Hz |
| Voltage detection threshold | < 194 V |
| Control circuit frequency | 50...60 Hz +/- 10 % |
| Measurement voltage limits | 176…528 V AC |
| Hysteresis | 2 % |
| delay at power up | 650 ms |
| Maximum measuring cycle | 140 ms measurement cycle as true rms value |
| Threshold adjustment voltage | 2...20 % of Un selected -12...-2 % in the range 220 V AC +2...+10 % in the range 480 V AC |
| Voltage range | 220...480 V phase to phase |
| Adjustment of asymmetry threshold | 5...15 % of Un selected |
| Repeat accuracy | 0.3 % for time delay 0.5 % for input and measurement circuit |
| Measurement error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
| Response time | < 200 ms (in the event of a fault) |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Supply frequency | 50/60 Hz +/- 10 % |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON LED (yellow) for fault |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
| Safety reliability data | MTTFd = 399.5 years B10d = 360000 |
| Width | 35 mm |
| Net weight | 0.13 kg |
| Control type | Without test button |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to IEC 61000-6-2 |
|---|---|
| Standards | IEC 60255-1 |
| Product certifications | GL UL CSA GOST C-Tick |
| Marking | CE |
| Directives | 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
| Non-dissipating shock wave | 4 kV |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.800 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.700 cm |
| Package 1 Weight | 133.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.070 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 64.124 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet: Download
Main Document
Data Sheet: Download
Reviews (0)
Recommended for you
-
0
Reviews
There are no reviews yet.