new-34%On Sale
Schneider A9N61526| miniature circuit breaker – C60H – 2 poles – 6 A – C curve
A9N61526
Description
Schneider A9N61526| miniature circuit breaker – C60H – 2 poles – 6 A – C curve
Schneider A9N61526 Description
The Schneider A9N61526 is a Miniature Circuit Breaker (MCB) from the Acti9 series, designed to provide protection and control for electrical circuits in residential, commercial, and industrial applications. Here’s a detailed description:
Schneider A9N61526 Miniature Circuit Breaker (MCB)
Key Features:
- Protection:
- Offers reliable protection against overcurrents, including both overloads and short circuits.
- Ensures the safety of electrical circuits by automatically interrupting the flow of excessive current.
- Rating:
- Current rating of 6A, making it suitable for protecting low-power circuits.
- Designed to handle specific breaking capacity, appropriate for residential and small commercial environments.
- Design:
- Compact, modular design for efficient use of space in distribution boards.
- Easily mountable on a DIN rail, facilitating integration with other modular devices.
- Performance:
- High performance with a rapid response to overcurrent conditions, ensuring minimal risk of damage.
- Guarantees continuous service by quickly isolating fault conditions.
- Indicators:
- Equipped with a visual trip indicator to provide quick and easy identification of the breaker’s status.
- Durability:
- Constructed with high-quality materials to ensure long-lasting durability and reliability.
- Meets international safety and performance standards.
Applications:
- Residential: Ideal for safeguarding electrical circuits in homes, including wiring, lighting, and appliances.
- Commercial: Suitable for protecting electrical circuits in small commercial buildings, ensuring the safety of office equipment and lighting systems.
- Industrial: Appropriate for low-power industrial applications, providing protection for control circuits and machinery.
Benefits:
- Enhanced Safety: Protects circuits from damage due to overloads and short circuits, reducing the risk of fire hazards and equipment damage.
- Easy Installation: The modular design allows for quick and straightforward installation and replacement.
- Cost-Effective: Reduces the need for maintenance and repair costs by providing reliable circuit protection.
- User-Friendly: Clear visual indicators and simple operation make it easy to use and monitor for electricians and maintenance personnel.
Considerations:
- Compatibility: Ensure the MCB is compatible with the specific electrical system and load requirements of your installation.
- Regular Testing: Periodically test the MCB to ensure it is functioning correctly and providing the necessary protection.
- Professional Installation: For optimal safety and performance, it is recommended to have a qualified electrician install and maintain the MCB.
Specifications:
- Model: Schneider A9N61526
- Series: Acti9
- Current Rating: 6A
- Poles: Single-pole
- Breaking Capacity: As per manufacturer specifications
Schneider Electric is renowned for producing high-quality electrical protection devices, and the A9N61526 MCB is a reliable choice for ensuring the safety and efficiency of your electrical systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Acti9 |
|---|---|
| Product name | Acti9 C60H-DC |
| product or component type | Miniature circuit-breaker |
| Device short name | C60H-DC |
| Device application | Distribution |
| poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 6 A at 25 °C |
| Network type | DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10 kA Icu at 440 V DC conforming to EN 60947-2 10 kA Icu at 440 V DC conforming to IEC 60947-2 6 kA Icu at 500 V DC conforming to EN 60947-2 6 kA Icu at 500 V DC conforming to IEC 60947-2 20 kA Icu at 220 V DC conforming to GB 14048.2 20 kA Icu at 220 V DC conforming to IEC 60947-2 20 kA Icu at 250 V DC conforming to GB 14048.2 20 kA Icu at 250 V DC conforming to IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 Yes conforming to EN 60947-2 |
| Network frequency | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage | 500 V DC |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN 60947-2 - 220 V DC 15 kA 75 % conforming to IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN 60947-2 - 250 V DC 15 kA 75 % conforming to IEC 60947-2 - 250 V DC 4.5 kA 75 % conforming to EN 60947-2 - 500 V DC 4.5 kA 75 % conforming to IEC 60947-2 - 500 V DC 7.5 kA 75 % conforming to EN 60947-2 - 440 V DC 7.5 kA 75 % conforming to IEC 60947-2 - 440 V DC |
| [Ui] rated insulation voltage | 500 V DC conforming to IEC 60947-2 500 V DC conforming to EN 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | ON/OFF indication |
| mounting mode | Fixed |
| mounting support | 35 mm symmetrical DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: standard |
| 9 mm pitches | 4 |
| net weight | 0.256 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 3000 cycles L/R = 2 ms |
| Provision for padlocking | Padlockable |
| Locking options description | In position O |
| Tightening torque | Power circuit: 2.5 N.m top or bottom |
| Earth-leakage protection | Without |
| Standards | EN 60947-2 IEC 60947-2 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-2 |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.5 cm |
| Package 1 Width | 3.6 cm |
| Package 1 Length | 8.5 cm |
| Package 1 Weight | 225 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 8 cm |
| Package 2 Width | 9 cm |
| Package 2 Length | 22 cm |
| Package 2 Weight | 1.398 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 72 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 17.25 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Be the first to review “Schneider A9N61526| miniature circuit breaker – C60H – 2 poles – 6 A – C curve” Cancel reply
Recommended for you
Schneider A9N61513 | miniature circuit breaker – C60H – 1 pole – 25 A – C curve
Schneider A9N61503 | miniature circuit breaker – C60H – 1 pole – 3 A – C curve
Schneider A9N61501 | miniature circuit breaker – C60H – 1 pole – 1 A – C curve
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N26929 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc