Description

Schneider RE48ATM12MW | On-delay timing relay – 0.02 s..300 h – 24..240 V AC – 2 OC

Schneider RE48ATM12MW – On-Delay Timing Relay

1. Overview

The Schneider RE48ATM12MW is a high-performance on-delay timing relay from the RE48 series. It is designed to delay the activation of an output after a predetermined time, making it ideal for use in automation, process control, and motor control systems. This relay is known for its wide timing range, universal voltage compatibility, and high reliability.

2. Technical Specifications

  • Product Series: RE48

  • Function: On-delay (delays closing of contact after power is applied)

  • Timing Range:

    • Adjustable from 0.02 seconds to 300 hours

    • Fine-tuning via rotary knobs on the front panel

  • Supply Voltage Range:

    • 24 to 240 V AC (universal input voltage)

  • Output Configuration:

    • 2 changeover contacts (2 CO / SPDT)

    • Maximum current: 8 A (resistive load)

  • Output Type: Electromechanical relay

  • Mounting:

    • Panel mounting (48 x 48 mm format)

    • DIN rail compatible

  • Connection: Screw clamp terminals

  • Accuracy:

    • Repeat accuracy: ±0.5%

  • Power Consumption:

    • Approx. ≤ 3.5 VA

  • Front Interface:

    • Dual potentiometers for timing adjustment

    • LED indicator for relay status

  • Protection Ratings:

    • IP50 (front panel), IP20 (housing)

  • Certifications:

    • CE, UL, CSA, RoHS compliant

3. Applications

The RE48ATM12MW is used in various industrial and commercial systems that require a delayed output after an input signal, including:

  • Industrial Automation: Delaying the start of machinery or production lines to prevent sudden load surges.

  • Motor Control: Gradual starting of motors to avoid inrush current issues.

  • HVAC Systems: Controlling sequential startup of fans, blowers, and compressors.

  • Pumping Systems: Used to delay pump operation after signal input for better system coordination.

  • Lighting Control: Providing a timed delay for turning on or off large lighting installations.

  • Packaging Machinery: Timing control in process sequences to maintain consistent operations.

4. Key Features

  • Wide Timing Range: Versatile use with timing from milliseconds to 300 hours.

  • On-Delay Function: Ensures controlled and safe activation of systems after a preset time.

  • Universal Voltage: Operates across multiple voltages (24–240 V AC), simplifying stock and installation.

  • Dual Output Contacts: Increases flexibility for multiple output control.

  • Compact Design: Standard 48×48 mm housing suitable for most panels.

  • User-Friendly Interface: Simple time setting using rotary knobs and clear LED status indication.

  • Reliable Performance: High repeat accuracy and long mechanical life.

Additional information

brands

Schneider Electric

Specifications

Main
Range of product Harmony Timer Relays
Electrical connection Plug-in sub-base 8 pin(s)
Width 48 mm
Product or component type Panel-mounted/plug-in timer relay
Discrete output type Relay
Contacts type and composition 2 C/O timed contacts, AgNi (cadmium free)
Component name RE48
Time delay range 5...300 h 2...120 min 0.5...30 h 0.2...12 h 0.2...12 min 0.2...12 s 0.5...30 min 2...120 h 2...120 s 0.02...1.2 s 0.5...30 s 5...300 s 0.05...3 s 5...300 min
[Us] rated supply voltage 24...240 V AC/DC 50/60 Hz
Voltage range 0.85...1.1 Us AC 0.9...1.1 Us DC
[In] rated current 5 A
Complementary
Product front plate size 48 x 48 mm
Control type Selector switch front panel
Housing material Self-extinguishing
Repeat accuracy +/- 0.2 % of the maximum setting value conforming to IEC 61812-1
Temperature drift +/- 0.02 %/°C of the maximum setting value conforming to IEC 61812-1
Voltage drift +/- 0.2 %/V of the maximum setting value at 48...240 V +/- 1 %/V of the maximum setting value at 24...48 V
Setting accuracy of time delay +/- 5 % of full scale at 25 °C conforming to IEC 61812-1 +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type Power on-delay - A1- Delay on energization
Minimum pulse duration 20 ms
Reset time 25 ms on de-energisation
Pick up duration 55 ms
On-load factor 100 %
Power consumption in VA 6 VA at 240 V
Power consumption in W 2 W at 240 V
Breaking capacity 1250 VA
minimum switching current 100 mA
Maximum switching current 5 A
Maximum switching voltage 250 V AC/DC
Electrical durability 100000 cycles
Mechanical durability 30000000 cycles
Output voltage 240 V at 5 A AC-12 30 V at 2 A DC-13 240 V at 1.5 A AC-15
Marking CE
Surge withstand 1 kV differential mode conforming to IEC 61000-4-5 level 3 2 kV common mode conforming to IEC 61000-4-5 level 3
Mounting support Panel mounted: system supplied with the product Base mounted: socket
Local signalling 1 LED (yellow) for output relay state LED indicator (green) for flashing: relay energised timing in progress LED indicator (green) for on steady: relay energised, no timing in progress
Function available A1- Delay on energization-2 C/O A2- Delay on energization-2 C/O H1-Pulse-on energization-2 C/O H2-Pulse-on energization-2 C/O
Control type Without test button
Net weight 0.14 kg
Shape of pin Cylindrical
Number of functions 1
Environment
Humidity drift +/- 0.05 %/%RH of the maximum setting value conforming to IEC 61812-1
Immunity to microbreaks 5 ms
Dielectric strength 2 kV 1 mA/1 minute conforming to IEC 61812-1
Protection against electric shocks 4 kV class III conforming to IEC 60664-1 4 kV class III conforming to IEC 61812-1
Standards 73/23/EEC 93/68/EEC EN 50082-1/2 89/336/EEC EN 50081-1/2 IEC 61812-1 IEC 60669-2-3
Product certifications UL cULus C-Tick CSA
Ambient air temperature for storage -40…70 °C
Ambient air temperature for operation -20…50 °C
IP degree of protection IP40 (housing) conforming to IEC 60529 IP50 (front face) conforming to IEC 60529
Vibration resistance 0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6
Relative humidity 93 % without condensation conforming to IEC 60068-2-3
Resistance to electrostatic discharge 6 kV in contact conforming to IEC 61000-4-2 level 3 8 kV in air conforming to IEC 61000-4-2 level 3
Resistance to electromagnetic fields 10 V/m 26 MHz to 1 GHz conforming to IEC 61000-4-3 level 3
Resistance to fast transients 2 kV (direct) conforming to IEC 61000-4-4 level 3 4 kV (direct) conforming to IEC 61000-4-4 level 4
Immunity to radioelectric fields 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 level 3
Immunity to voltage dips 30 % / 10 ms conforming to IEC 61000-4-11 95 % / 5 s conforming to IEC 61000-4-11 60 % / 100 ms conforming to IEC 61000-4-11
Disturbance radiated/conducted Class B 0.15...30 MHz conforming to EN 55022 (EN 55011 group 1)
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.7 cm
Package 1 Width 10.5 cm
Package 1 Length 6.2 cm
Package 1 Weight 126 g
Unit Type of Package 2 S02
Number of Units in Package 2 30
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 4.252 kg
Contractual warranty
Warranty 18 months

Main documents

Main documents

Datasheet Download Datasheet
Product datasheet Download
Instruction sheet
Download
Catalog Download
Environmental disclosure
Download
CAD Files Download

Main documents

Datasheet Download Datasheet
Product datasheet Download
Instruction sheet
Download
Catalog Download
Environmental disclosure
Download
CAD Files Download

Reviews (0)

Be the first to review “Schneider RE48ATM12MW | On-delay timing relay – 0.02 s..300 h – 24..240 V AC – 2 OC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare