LV510304
Description
1. Technical Specifications Schneider LV510304
-
Model: LV510304
-
Series: EasyPact CVS100B
-
Type: Molded Case Circuit Breaker (MCCB)
-
Rated Current (In): 50 A
-
Breaking Capacity (Icu): 25 kA at 415V AC
-
Voltage Rating: 415V AC, 50/60 Hz
-
Trip Unit Type: TM-D (Thermal Magnetic)
-
Thermal Protection: Adjustable (typically 0.7 × In to 1 × In)
-
Magnetic Protection: Fixed (factory-set for short-circuit protection)
-
Number of Poles: 3P
-
Protection Configuration: 3d (protection on all three poles)
-
Mounting Style: Fixed, panel-mounted
-
Operating Mechanism: Toggle switch with clear ON/OFF indication
-
Standards: IEC 60947-2 compliant
-
Mechanical Endurance: Up to 10,000 operations
-
Electrical Endurance: Up to 4,000 operations under standard load
2. Key Features Schneider LV510304
High Short-Circuit Capacity
Capable of interrupting fault currents up to 25 kA at 415V AC, the breaker ensures safety in systems with high prospective short-circuit currents.
Thermal Magnetic Protection
The TM-D trip unit provides two levels of protection:
-
Thermal (overload): adjustable for various load profiles
-
Magnetic (short-circuit): fast and reliable interruption of high fault currents
Fully Rated 3-Pole Design
The 3P 3d configuration ensures full protection across all three phases, ideal for three-phase systems used in industrial and commercial environments.
Adjustable Thermal Trip
Enables fine-tuning of overload protection to match system and equipment requirements, reducing nuisance tripping and increasing operational flexibility.
Durable and Easy to Install
Built for long service life with compact dimensions, easy mounting, and compatibility with Schneider accessories for future upgrades.
3. Typical Applications
-
Distribution Boards: Protection for sub-circuits in commercial and industrial buildings
-
Motor Circuits: Works with contactors to protect medium-sized motors
-
Control Panels: Circuit protection in automated systems and machine panels
-
Pumps and Compressors: Suitable for mechanical systems requiring circuit-level protection
-
Commercial Lighting and HVAC: Ensures safe operation of lighting grids and air-conditioning units
-
Generator Panels: Overcurrent protection in backup or emergency power systems
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Range of product | EasyPact CVS100...250 |
| Product name | EasyPact CVS |
| Device short name | CVS100B |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| Earth leakage protection (Vigi add on) | Without |
| [In] rated current | 50 A at 40 °C |
| network type | AC |
| Utilisation category | Category A |
| [Icu] Breaking capacity | 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 50 A at 40 °C |
| Protection type | Overload protection (thermal) Short-circuit protection (magnetic) |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|---|
| network frequency | 50/60 Hz |
| Breaking capacity code | B |
| [Ics] rated service breaking capacity | 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 12000 cycles 415 V In conforming to IEC 60947-2 |
| Control type | Toggle |
| Thermal protection adjustment range | 35…50 A |
| Long time pick-up adjustment type Ir | Adjustable |
| Long time pick-up adjustment range | 0.7...1 x In |
| Long time delay adjustment type | Fixed |
| Instantaneous pick-up adjustment type Ii | Fixed |
| instantaneous pick-up adjustment range | 500 A |
| Contact position indicator | Yes |
| mounting support | Backplate |
| mounting mode | Fixed |
| Upside connection | Front |
| downside connection | Front |
| Connections - terminals | Screw connection |
| Connection pitch | 35 mm |
| Compatibility code | CVS100 |
| Width | 105 mm |
| Depth | 86 mm |
| Height | 161 mm |
| Net weight | 1.5 kg |
| Standards | EN 60947-2 IEC 60947-2 |
|---|---|
| Product certifications | GOST IEC |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.000 cm |
| Package 1 Width | 13.500 cm |
| Package 1 Length | 19.000 cm |
| Package 1 Weight | 1.660 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 13.700 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 64 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 121.600 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Be the first to review “Schneider LV510304 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 50 A rating thermal magnetic TM-D trip unit, 3P 3d” Cancel reply
Recommended for you
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18446 | Miniature circuit-breaker, Acti9 C120H, 1P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18369 | Miniature circuit-breaker, Acti9 C120N, 3P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Acti 9 C120, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9N18357 | Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
Acti 9 iK60, Acti 9 iK60, Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, Low Voltage Products and Systems
-
0
Schneider A9K24232 | Miniature circuit-breaker, Acti9 iK60N, 2P, 32 A, C curve, 6000 A (IEC 60898-1)
Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, iC60, Low Voltage Products and Systems
-
0
Schneider A9F94463 | Miniature circuit-breaker, Acti9 iC60L, 4P, 63 A, C curve, 15 kA (IEC 60947-2)
Acti 9 Miniature Circuit Breakers - MCBs, Din rail modular devices, iC60, Low Voltage Products and Systems
-
0
Reviews
There are no reviews yet.